Sökning: onr:"swepub:oai:prod.swepub.kib.ki.se:125843787" >
Effective dose of c...
Effective dose of cone beam computed tomography (CBCT) of the facial skeleton : a systematic review
-
- Al-Okshi, Ayman (författare)
- Malmö högskola,Odontologiska fakulteten (OD)
-
- Lindh, Christina (författare)
- Malmö högskola,Odontologiska fakulteten (OD)
-
- Salé, Hanna (författare)
- Malmö högskola,Odontologiska fakulteten (OD)
-
visa fler...
-
Gunnarsson, Mikael (författare)
-
- Rohlin, Madeleine (författare)
- Malmö högskola,Odontologiska fakulteten (OD)
-
visa färre...
-
(creator_code:org_t)
- British Institute of Radiology, 2015
- 2015
- Engelska.
-
Ingår i: British Journal of Radiology. - : British Institute of Radiology. - 0007-1285 .- 1748-880X. ; 88:1045
- Relaterad länk:
-
https://europepmc.or...
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Objective: To estimate effective dose of cone beam CT (CBCT) of the facial skeleton with focus on measurement methods and scanning protocols. Methods: A systematic review, which adhered to the preferred reporting items for systematic reviews (PRISMA) Statement, of the literature up to April 2014 was conducted. Data sources included MEDLINE®, The Cochrane Library and Web of Science. A model was developed to underpin data extraction from 38 included studies. Results: Technical specifications of the CBCT units were insufficiently described. Heterogeneity in measurement methods and scanning protocols between studies made comparisons of effective doses of different CBCT units and scanning protocols difficult. Few studies related doses to image quality. Reported effective dose varied across studies, ranging between 9.7 and 197.0 mSv for field of views (FOVs) with height #5cm, between 3.9 and 674.0 mSv for FOVs of heights 5.1–10.0 cm and between 8.8 and 1073.0 mSv for FOVs .10 cm. There was an inconsistency regarding reported effective dose of studies of the same CBCT unit with the same FOV dimensions. Conclusion: The review reveals a need for studies on radiation dosages related to image quality. Reporting quality of future studies has to be improved to facilitate comparison of effective doses obtained from examinations with different CBCT units and scanning protocols. A model with minimum data set on important parameters based on this observation is proposed. Advances in knowledge: Data important when estimating effective dose were insufficiently reported in most studies. A model with minimum data based on this observation is proposed. Few studies related effective dose to image quality.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Odontologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Dentistry (hsv//eng)
Publikations- och innehållstyp
- ref (ämneskategori)
- for (ämneskategori)
Hitta via bibliotek
Till lärosätets databas