SwePub
Sök i LIBRIS databas

  Utökad sökning

(id:"swepub:oai:DiVA.org:umu-90869")
 

Sökning: (id:"swepub:oai:DiVA.org:umu-90869") > Tumor Volumes Measu...

Tumor Volumes Measured From Static and Dynamic F-18-fluoro-2-deoxy-D-glucose Positron Emission Tomography-Computed Tomography Scan : Comparison of Different Methods Using Magnetic Resonance Imaging as the Criterion Standard

Chen, Hanwei (författare)
Jiang, Jinzhao (författare)
Gao, Junling (författare)
visa fler...
Liu, Dan (författare)
Axelsson, Jan (författare)
Umeå universitet,Radiofysik
Cui, Minyi (författare)
Gong, Nan-Jie (författare)
Feng, Shi-Ting (författare)
Luo, Liangping (författare)
Huang, Bingsheng (författare)
visa färre...
 (creator_code:org_t)
2014
2014
Engelska.
Ingår i: Journal of computer assisted tomography. - 0363-8715 .- 1532-3145. ; 38:2, s. 209-215
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective: The objective of this study was to compare the accuracy of calculating the primary tumor volumes using a gradient-based method and fixed threshold methods on the standardized uptake value (SUV) maps and the net influx of FDG (Ki) maps from positron emission tomography-computed tomography (PET-CT) images. Materials and Methods: Newly diagnosed patients with head and neck cancer were recruited, and dynamic PET-CT scan and T2-weighted magnetic resonance imaging were performed. The maps of Ki and SUV were calculated from PET-CT images. The tumor volumes were calculated using a gradient-based method and a fixed threshold method at 40% of maximal SUV or maximal Ki. Four kinds of volumes, VOLKi-Gra (from the Ki maps using the gradient-based method), VOLKi-40% (from the Ki maps using the threshold of 40% maximal Ki), VOLSUV-Gra (from the SUV maps using the gradient-based method), and VOLSUV-40% (from the SUV maps using the threshold of 40% maximal SUV), were acquired and compared with VOLMRI (the volumes acquired on T2-weighted images) using the Pearson correlation, paired t test, and similarity analysis. Results: Eighteen patients were studied, of which 4 had poorly defined tumors (PDT). The positron emission tomography-derived volumes were as follows: VOLSUV-40%, 2.1 to 41.2 cm(3) (mean [SD], 12.3 [10.6]); VOLSUV-Gra, 2.2 to 28.1 cm(3) (mean [SD], 13.2 [8.4]); VOLKi-Gra, 2.4 to 17.0 cm(3) (mean [SD], 9.5 [4.6]); and VOLKi-40%, 2.7 to 20.3 cm(3) (mean [SD], 12.0 [6.0]). The VOLMRI ranged from 2.9 to 18.1 cm(3) (mean [SD], 9.1 [3.9]). The VOLKi-Gra significantly correlated with VOLMRI with the highest correlation coefficient (PDT included, R = 0.673, P = 0.002; PDT excluded, R = 0.841, P < 0.001) and presented no difference from VOLMRI (P = 0.672 or 0.561, respectively, PDT included and excluded). The difference between VOLKi-Gra and VOLMRI was also the smallest. Conclusions: The tumor volumes delineated on the Ki maps using the gradient-based method are more accurate than those on the SUV maps and using the fixed threshold methods.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Nyckelord

dynamic PET-CT scan
head and neck cancer
tumor volume
gradient-based method

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy