SwePub
Sök i LIBRIS databas

  Utökad sökning

(id:"swepub:oai:slubar.slu.se:62637")
 

Sökning: (id:"swepub:oai:slubar.slu.se:62637") > Validation of a com...

Validation of a commercially available automated canine-specific immunoturbidimetric method for measuring canine C-reactive protein

Hillström, Anna (författare)
Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Institutionen för kliniska vetenskaper (KV),Department of Clinical Sciences
Hagman, Ragnvi (författare)
Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Institutionen för kliniska vetenskaper (KV),Department of Clinical Sciences
Tvedten, Harold (författare)
Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Institutionen för kliniska vetenskaper (KV),Department of Clinical Sciences
 (creator_code:org_t)
 
2014-05-05
2014
Engelska.
Ingår i: Veterinary Clinical Pathology. - : Wiley. - 0275-6382 .- 1939-165X. ; 43, s. 235-243
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background Measurement of C-reactive protein (CRP) is used for diagnosing and monitoring systemic inflammatory disease in canine patients. An automated human immunoturbidimetric assay has been validated for measuring canine CRP, but cross-reactivity with canine CRP is unpredictable. Objective The purpose of the study was to validate a new automated canine-specific immunoturbidimetric CRP method (Gentian cCRP). Methods Studies of imprecision, accuracy, prozone effect, interference, limit of quantification, and stability under different storage conditions were performed. The new method was compared with a human CRP assay previously validated for canine CRP determination. Samples from 40 healthy dogs were analyzed to establish a reference interval. Results Total imprecision was < 2.4% for 4 tested serum pools analyzed twice daily over 10days. The method was linear under dilution, and no prozone effect was detected at a concentration of 1200mg/L. Recovery after spiking serum with purified canine CRP at 2 different concentrations was 123% and 116%, respectively. No interference from hemoglobin or triglycerides (10g/L) was detected. CRP was stable for 14days at 4 degrees C and 22 degrees C. In the method comparison study, there was good agreement between the validated human CRP assay and the new canine-specific assay. Healthy dogs had CRP concentrations that were less than the limit of quantification of the Gentian cCRP method (6.8mg/L). Conclusions The new canine-specific immunoturbidimetric CRP assay is a reliable and rapid method for measuring canine CRP, suitable for clinical use due to the option for an automated assay.

Ämnesord

LANTBRUKSVETENSKAPER  -- Veterinärmedicin -- Klinisk vetenskap (hsv//swe)
AGRICULTURAL SCIENCES  -- Veterinary Science -- Clinical Science (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Hillström, Anna
Hagman, Ragnvi
Tvedten, Harold
Om ämnet
LANTBRUKSVETENSKAPER
LANTBRUKSVETENSK ...
och Veterinärmedicin
och Klinisk vetenska ...
Artiklar i publikationen
Veterinary Clini ...
Av lärosätet
Sveriges Lantbruksuniversitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy