What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer?
-
Ekberg, Lars (författare)
-
- Holmberg, Ola (författare)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
-
- Wittgren, Lena (författare)
- Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine
-
visa fler...
-
- Bjelkengren, Göran (författare)
- Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine
-
- Landberg, Torsten (författare)
- Lund University,Lunds universitet,Medicinska fakulteten,Faculty of Medicine
-
visa färre...
-
(creator_code:org_t)
- 1988
- 1988
- Engelska.
-
Ingår i: Radiotherapy and Oncology. - 1879-0887. ; 48:1, s. 71-77
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- BACKGROUND: The planning target volume in radiotherapy treatment planning takes into account both movements of the clinical target volume (CTV) and set-up deviations. MATERIALS AND METHODS: A group of patients who received radiotherapy for lung cancer were studied. In order to measure the CTV movements due to respiration and other internal organ motions, fluoroscopy was performed for 20 patients. To study the accuracy and reproducibility of patient and beam set-up, 553 electronic portal images from 20 patients were evaluated. Discrepancies between planned and actual field positions were measured and the systematic and random errors were identified. The combined effect of these geometrical variations was evaluated. RESULTS: The average CTV movement with quiet respiration was about 2.4 mm in the medio-lateral and dorso-ventral directions. Movement in the cranio-caudal direction was on average 3.9 mm with a range of 0-12 mm. The systematic set-up errors were on average 2.0 mm in the transversal plane and 3.0 mm in the cranio-caudal direction. The random errors can be described by their standard deviations of 3.2 and 2.6 mm. In this study, the combined effect of the two parameters (CTV movement and set-up deviations) varied between 7.5 and 10.3 mm in different anatomical directions. CONCLUSIONS: In our daily clinical routine, we use a margin of 11 mm in the transversal plane and 15 mm cranially and caudally, also taking into account other unquantified variations and uncertainties.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cancer and Oncology (hsv//eng)