SwePub
Sök i SwePub databas

  Utökad sökning

Booleska operatorer måste skrivas med VERSALER

AND är defaultoperator och kan utelämnas

Träfflista för sökning "AMNE:(MEDICAL AND HEALTH SCIENCES Clinical Medicine Radiology, Nuclear Medicine and Medical Imaging) ;mspu:(researchreview)"

Sökning: AMNE:(MEDICAL AND HEALTH SCIENCES Clinical Medicine Radiology, Nuclear Medicine and Medical Imaging) > Forskningsöversikt

  • Resultat 1-10 av 211
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schöll, Michael, 1980, et al. (författare)
  • Biomarkers for tau pathology.
  • 2019
  • Ingår i: Molecular and cellular neurosciences. - : Elsevier BV. - 1095-9327 .- 1044-7431. ; 97, s. 18-33
  • Forskningsöversikt (refereegranskat)abstract
    • The aggregation of fibrils of hyperphosphorylated and C-terminally truncated microtubule-associated tau protein characterizes 80% of all dementia disorders, the most common neurodegenerative disorders. These so-called tauopathies are hitherto not curable and their diagnosis, especially at early disease stages, has traditionally proven difficult. A keystone in the diagnosis of tauopathies was the development of methods to assess levels of tau protein in vivo in cerebrospinal fluid, which has significantly improved our knowledge about these conditions. Tau proteins have also been measured in blood, but the importance of tau-related changes in blood is still unclear. The recent addition of positron emission tomography ligands to visualize, map and quantify tau pathology has further contributed with information about the temporal and spatial characteristics of tau accumulation in the living brain. Together, the measurement of tau with fluid biomarkers and positron emission tomography constitutes the basis for a highly active field of research. This review describes the current state of biomarkers for tau biomarkers derived from neuroimaging and from the analysis of bodily fluids and their roles in the detection, diagnosis and prognosis of tau-associated neurodegenerative disorders, as well as their associations with neuropathological findings, and aims to provide a perspective on how these biomarkers might be employed prospectively in research and clinical settings.
  •  
2.
  • Rösch, Frank, et al. (författare)
  • Radiolanthanides in nuclear medicine.
  • 2004
  • Ingår i: Metal ions in biological systems. - 0161-5149. ; 42, s. 77-108
  • Forskningsöversikt (refereegranskat)
  •  
3.
  • Friedli, Iris, et al. (författare)
  • Magnetic Resonance Imaging in Clinical Trials of Diabetic Kidney Disease
  • 2023
  • Ingår i: Journal of Clinical Medicine. - 2077-0383. ; 12:14
  • Forskningsöversikt (refereegranskat)abstract
    • Chronic kidney disease (CKD) associated with diabetes mellitus (DM) (known as diabetic kidney disease, DKD) is a serious and growing healthcare problem worldwide. In DM patients, DKD is generally diagnosed based on the presence of albuminuria and a reduced glomerular filtration rate. Diagnosis rarely includes an invasive kidney biopsy, although DKD has some characteristic histological features, and kidney fibrosis and nephron loss cause disease progression that eventually ends in kidney failure. Alternative sensitive and reliable non-invasive biomarkers are needed for DKD (and CKD in general) to improve timely diagnosis and aid disease monitoring without the need for a kidney biopsy. Such biomarkers may also serve as endpoints in clinical trials of new treatments. Non-invasive magnetic resonance imaging (MRI), particularly multiparametric MRI, may achieve these goals. In this article, we review emerging data on MRI techniques and their scientific, clinical, and economic value in DKD/CKD for diagnosis, assessment of disease pathogenesis and progression, and as potential biomarkers for clinical trial use that may also increase our understanding of the efficacy and mode(s) of action of potential DKD therapeutic interventions. We also consider how multi-site MRI studies are conducted and the challenges that should be addressed to increase wider application of MRI in DKD.
  •  
4.
  • Neuen, B. L., et al. (författare)
  • Predictors of Patency after Balloon Angioplasty in Hemodialysis Fistulas: A Systematic Review
  • 2014
  • Ingår i: Journal of Vascular and Interventional Radiology. - : Elsevier BV. - 1051-0443. ; 25:6, s. 917-924
  • Forskningsöversikt (refereegranskat)abstract
    • Percutaneous transluminal angioplasty (PTA) is an established treatment for dysfunctional hemodialysis fistulas. This article systematically reviews evidence for predictors of patency after PTA. Outcomes assessed were primary, assisted primary, and secondary patency after intervention, and findings were summarized descriptively. This review included 11 nonrandomized observational studies of 965 fistulas in 939 patients. Follow-up ranged from 0 days to 10 years. Study quality was overall Suboptimal. Newer fistulas and longer lesion length may be associated with primary potency loss after PTA. Further studies are needed to confirm these findings, to identify potentially modifiable factors, and to guide the testing of new endovascular devices.
  •  
5.
  • Siegel, T. P., et al. (författare)
  • Mass Spectrometry Imaging and Integration with Other Imaging Modalities for Greater Molecular Understanding of Biological Tissues
  • 2018
  • Ingår i: Molecular Imaging and Biology. - : Springer Science and Business Media LLC. - 1536-1632 .- 1860-2002. ; 20:6, s. 888-901
  • Forskningsöversikt (refereegranskat)abstract
    • Over the last two decades, mass spectrometry imaging (MSI) has been increasingly employed to investigate the spatial distribution of a wide variety of molecules in complex biological samples. MSI has demonstrated its potential in numerous applications from drug discovery, disease state evaluation through proteomic and/or metabolomic studies. Significant technological and methodological advancements have addressed natural limitations of the techniques, i.e., increased spatial resolution, increased detection sensitivity especially for large molecules, higher throughput analysis and data management. One of the next major evolutions of MSI is linked to the introduction of imaging mass cytometry (IMC). IMC is a multiplexed method for tissue phenotyping, imaging signalling pathway or cell marker assessment, at sub-cellular resolution (1m). It uses MSI to simultaneously detect and quantify up to 30 different antibodies within a tissue section. The combination of MSI with other molecular imaging techniques can also provide highly relevant complementary information to explore new scientific fields. Traditionally, classical histology (especially haematoxylin and eosin-stained sections) is overlaid with molecular profiles obtained by MSI. Thus, MSI-based molecular histology provides a snapshot of a tissue microenvironment and enables the correlation of drugs, metabolites, lipids, peptides or proteins with histological/pathological features or tissue substructures. Recently, many examples combining MSI with other imaging modalities such as fluorescence, confocal Raman spectroscopy and MRI have emerged. For instance, brain pathophysiology has been studied using both MRI and MSI, establishing correlations between in and ex vivo molecular imaging techniques. Endogenous metabolite and small peptide modulation were evaluated depending on disease state. Here, we review advanced hot topics' in MSI development and explore the combination of MSI with established molecular imaging techniques to improve our understanding of biological and pathophysiological processes.
  •  
6.
  • Szaro, Pavel, 1981, et al. (författare)
  • Magnetic resonance imaging of the brachial plexus. Part 1: Anatomical considerations, magnetic resonance techniques, and non-traumatic lesions
  • 2022
  • Ingår i: European Journal of Radiology Open (EJR Open). - : Elsevier BV. - 2352-0477. ; 9
  • Forskningsöversikt (refereegranskat)abstract
    • For magnetic resonance imaging (MRI) of non-traumatic brachial plexus (BP) lesions, sequences with contrast injection should be considered in the differentiation between tumors, infection, postoperative conditions, and post-radiation changes. The most common non-traumatic inflammatory BP neuropathy is radiation neuropathy. T2-weighted images may help to distinguish neoplastic infiltration showing a high signal from radiation-induced neuropathy with fibrosis presenting a low signal. MRI findings in inflammatory BP neuropathy are usually absent or discrete. Diffuse edema of the BP localized mainly in the supraclavicular part of BP, with side-to-side differences, and shoulder muscle denervation may be found on MRI. BP infection is caused by direct infiltration from septic arthritis of the shoulder joint, spondylodiscitis, or lung empyema. MRI may help to narrow down the list of differential diagnoses of tumors. The most common tumor of BP is metastasis. The most common primary tumor of BP is neurofibroma, which is visible as fusiform thickening of a nerve. In its solitary state, it may be challenging to differentiate from a schwannoma. The most common MRI finding is a neurogenic variant of thoracic outlet syndrome with an asymmetry of signal and thickness of the BP with edema. In abduction, a loss of fat directly related to the BP may be seen. Diffusion tensor imaging is a promising novel MRI sequences; however, the small diameter of the nerves contributing to the BP and susceptibility to artifacts may be challenging in obtaining sufficiently high-quality images.
  •  
7.
  • Nyman, Ulf, et al. (författare)
  • Revised Swedish guidelines on intravenous iodine contrast medium-induced acute kidney injury 2022: A summary
  • 2023
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 64:5
  • Forskningsöversikt (refereegranskat)abstract
    • The Swedish Society of Uroradiology has revised their computed tomography (CT) guidelines regarding iodine contrast media-induced acute kidney injury (CI-AKI). They are more cautious compared to the European Society of Urogenital Radiology and the American College of Radiology since the actual risk of CI-AKI remains uncertain in patients with moderate to severe kidney damage due to a lack of prospective controlled studies and mainly based on retrospective propensity score-matched studies with low-grade evidence. Another source of uncertainty is the imprecision of glomerular filtration rate (GFR) estimating equations. However, randomized hydration studies indictae an upper limit risk of CI-AKI of about 5% for outpatients with a GFR in the range of 30-44 or 45-59 mL/min/1.73m(2) combined with multiple risk factors. Apart from GFR limits, the guideline also includes limits for systemic contrast medium exposure expressed in gram-iodine/GFR ratio.
  •  
8.
  • Rahman Jabin, MD Shafiqur, et al. (författare)
  • Effectiveness of quality improvement interventions for patient safety in radiology : a systematic review protocol
  • 2016
  • Ingår i: The JBI Database of Systematic Reviews and Implementation Reports. - : Lippincott Williams & Wilkins. - 2202-4433. ; 14:9, s. 65-78
  • Forskningsöversikt (refereegranskat)abstract
    • The objective of this review is to find the best available evidence regarding effectiveness of quality improvement interventions in clinical radiology and the experiences and perspectives of staff and patients. More specifically, the review questions are:How effective are the interventions that may improve or affect patient safety and quality in clinical radiology?What are the experiences and perspectives of staff and patients of patient safety and quality improvement interventions?
  •  
9.
  • Wisniewski, Karol, et al. (författare)
  • H3 K27M-Altered Diffuse Midline Gliomas : A Review
  • 2023
  • Ingår i: Indian Journal of Neurosurgery. - : Georg Thieme Verlag KG. - 2277-954X .- 2277-9167. ; 12:02, s. 104-115
  • Forskningsöversikt (refereegranskat)abstract
    • Diffuse midline glioma H3 K27M-altered is a recently renamed high-grade glioma in the 2021 World Health Organization (WHO) Classification of Central Nervous System Tumors, previously being labelled diffuse midline glioma H3 K27M-mutant in the 2016 update and diffuse intrinsic pontine glioma prior to 2016. After identification of multiple alterations causing H3 K27 hypomethylation, the definition of this tumor subtype was changed. To further characterize this new entity in both the pediatric and adult population, we conducted a review of the current literature, investigating genetic, epidemiological, clinical, radiological, histopathological, treatment and prognostic characteristics, particularly highlighting the differences between adults and children. This tumor is more common in children, and has a poorer prognosis. Additionally, childhood H3 K27-altered gliomas are more common in the brainstem, but more common in the thalamus in adults. Sadly, limited treatment options exist for these tumors, with radiotherapy the only treatment shown to improve overall survival.
  •  
10.
  • Bissell, Malenka M., et al. (författare)
  • 4D Flow cardiovascular magnetic resonance consensus statement : 2023 update
  • 2023
  • Ingår i: Journal of Cardiovascular Magnetic Resonance. - : BMC. - 1097-6647 .- 1532-429X. ; 25:1
  • Forskningsöversikt (refereegranskat)abstract
    • Hemodynamic assessment is an integral part of the diagnosis and management of cardiovascular disease. Four-dimensional cardiovascular magnetic resonance flow imaging (4D Flow CMR) allows comprehensive and accurate assessment of flow in a single acquisition. This consensus paper is an update from the 2015 ‘4D Flow CMR Consensus Statement’. We elaborate on 4D Flow CMR sequence options and imaging considerations. The document aims to assist centers starting out with 4D Flow CMR of the heart and great vessels with advice on acquisition parameters, post-processing workflows and integration into clinical practice. Furthermore, we define minimum quality assurance and validation standards for clinical centers. We also address the challenges faced in quality assurance and validation in the research setting. We also include a checklist for recommended publication standards, specifically for 4D Flow CMR. Finally, we discuss the current limitations and the future of 4D Flow CMR. This updated consensus paper will further facilitate widespread adoption of 4D Flow CMR in the clinical workflow across the globe and aid consistently high-quality publication standards.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 211
Typ av publikation
Typ av innehåll
refereegranskat (204)
övrigt vetenskapligt/konstnärligt (7)
Författare/redaktör
Tolmachev, Vladimir (7)
Nilsson, Markus (7)
Knutsson, Linda (7)
Ljungberg, Michael (6)
Haller, Sven (5)
Geijer, Håkan, 1961- (4)
visa fler...
Eriksson, Olof (4)
Persson, Bertil R (4)
Velikyan, Irina, 196 ... (4)
Zackrisson, Sophia (3)
Sörensen, Jens (3)
Orlova, Anna, 1960- (3)
Geijer, Mats, 1957 (3)
Sundgren, Pia C. (3)
Larsson, Elna-Marie (3)
Mattsson, Sören (3)
Szczepankiewicz, Fil ... (3)
Ståhlberg, Freddy (3)
Forssell-Aronsson, E ... (3)
van Westen, Danielle (3)
Flachskampf, Frank, ... (3)
Wollmer, Per (2)
Henein, Michael Y. (2)
Lundberg, Peter (2)
Kihlberg, Johan (2)
Ahlman, Håkan, 1947 (2)
Geijer, Mats (2)
Marsal, Karel (2)
Helms, Gunther (2)
Ekberg, Olle (2)
Strand, Sven-Erik (2)
Wirestam, Ronnie (2)
Iima, Mami (2)
Barkhof, Frederik (2)
Ricci, Fabrizio (2)
Alexander, Daniel C. (2)
Dyrby, Tim B. (2)
De Caterina, Raffael ... (2)
Lubberink, Mark (2)
Booij, Ronald (2)
Oei, Edwin H. G. (2)
Saba, Luca (2)
Nordberg, Agneta (2)
Falk Delgado, Albert ... (2)
Heurling, Kerstin (2)
Cremonesi, Marta (2)
Oyen, Wim J G (2)
Valentin, Lil (2)
Björkman-Burtscher, ... (2)
Tingberg, Anders (2)
visa färre...
Lärosäte
Lunds universitet (98)
Uppsala universitet (59)
Karolinska Institutet (24)
Linköpings universitet (21)
Göteborgs universitet (19)
Umeå universitet (14)
visa fler...
Örebro universitet (9)
Stockholms universitet (5)
Kungliga Tekniska Högskolan (4)
Chalmers tekniska högskola (4)
Malmö universitet (1)
Linnéuniversitetet (1)
Blekinge Tekniska Högskola (1)
Sveriges Lantbruksuniversitet (1)
visa färre...
Språk
Engelska (202)
Svenska (8)
Tyska (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (211)
Naturvetenskap (19)
Teknik (5)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy