SwePub
Sök i SwePub databas

  Utökad sökning

Booleska operatorer måste skrivas med VERSALER

AND är defaultoperator och kan utelämnas

Träfflista för sökning "AMNE:(MEDICAL AND HEALTH SCIENCES Clinical Medicine Radiology, Nuclear Medicine and Medical Imaging) ;pers:(Andersson Ingvar)"

Sökning: AMNE:(MEDICAL AND HEALTH SCIENCES Clinical Medicine Radiology, Nuclear Medicine and Medical Imaging) > Andersson Ingvar

  • Resultat 1-10 av 61
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Matson, Sophia, et al. (författare)
  • Nonattendance in mammographic screening: a study of intraurban differences in Malmo, Sweden, 1990-1994
  • 2001
  • Ingår i: Cancer Detection and Prevention. - 0361-090X. ; 25:2, s. 132-137
  • Tidskriftsartikel (refereegranskat)abstract
    • Mammographic screening may reduce breast cancer mortality. Not all women, however, come for examination. The objective in this study from Malmo has been to assess extent to which the rate of nonattendance varies between residential areas with different sociodemographic profiles. The study is based on 32,605 women, 45 to 68 years old and living in 17 areas, who between 1990 and 1994 were invited to screening. Between age groups, the age-specific nonattendance rate ranged from 31% to 35 % (P < .01). The nonattendance rate was highest for women 65 years or older. Between residential areas, age-adjusted nonattendance rates ranged from 23% to 43% (P < .01). A socioeconomic score was developed to express the socioeconomic circumstances in the residential areas and ranged from -7.18 in the most deprived area to 5.01 in the least. Nonattendance covaried in an inverse fashion with the socioeconomic score (r = -0.78; P < .01). One of three women in this urban population did not accept the invitation to mammographic screening. Our conclusion is that women in areas with less favorable circumstances seem to be less willing to participate.
  •  
2.
  • Dustler, Magnus, et al. (författare)
  • Can mechanical imaging increase the specificity of mammography screening?
  • 2017
  • Ingår i: European Radiology. - : Springer Science and Business Media LLC. - 0938-7994 .- 1432-1084. ; 27:8, s. 3217-3225
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: This study aimed to investigate the effects of adding adjunct mechanical imaging to mammography breast screening. We hypothesized that mechanical imaging could detect increased local pressure caused by both malignant and benign breast lesions and that a pressure threshold for malignancy could be established. The impact of this on breast screening was investigated with regard to reductions in recall and biopsy rates. Methods: 155 women recalled from breast screening were included in the study, which was approved by the regional ethical review board (dnr 2013/620). Mechanical imaging readings were acquired of the symptomatic breast. The relative mean pressure on the suspicious area (RMPA) was defined and a threshold for malignancy was established. Results: Biopsy-proven invasive cancers had a median RMPA of 3.0 (interquartile range (IQR) = 3.7), significantly different from biopsy-proven benign at 1.3 (IQR = 1.0) and non-biopsied cases at 1.0 (IQR = 1.3) (P < 0.001). The lowest RMPA for invasive cancer was 1.4, with 23 biopsy-proven benign and 33 non-biopsied cases being below this limit. Had these women not been recalled, recall rates would have been reduced by 36% and biopsy rates by 32%. Conclusions: If implemented in a screening situation, this may substantially lower the number of false positives. Key Points: • Mechanical imaging is used as an adjunct to mammography in breast screening.• A threshold pressure can be established for malignant breast cancer.• Recalls and biopsies can be substantially reduced.
  •  
3.
  • Ruschin, Mark, et al. (författare)
  • Dose dependence of mass and microcalcification detection in digital mammography: free response human observer studies.
  • 2007
  • Ingår i: Medical physics. - : Wiley. - 0094-2405. ; 34:2, s. 400-7
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of this study was to evaluate the effect of dose reduction in digital mammography on the detection of two lesion types-malignant masses and clusters of microcalcifications. Two free-response observer studies were performed-one for each lesion type. Ninety screening images were retrospectively selected; each image was originally acquired under automatic exposure conditions, corresponding to an average glandular dose of 1.3 mGy for a standard breast (50 mm compressed breast thickness with 50% glandularity). For each study, one to three simulated lesions were added to each of 40 images (abnormals) while 50 were kept without lesions (normals). Two levels of simulated system noise were added to the images yielding two new image sets, corresponding to simulated dose levels of 50% and 30% of the original images (100%). The manufacturer's standard display processing was subsequently applied to all images. Four radiologists experienced in mammography evaluated the images by searching for lesions and marking and assigning confidence levels to suspicious regions. The search data were analyzed using jackknife free-response (JA-FROC) methodology. For the detection of masses, the mean figure-of-merit (FOM) averaged over all readers was 0.74, 0.71, and 0.68 corresponding to dose levels of 100%, 50%, and 30%, respectively. These values were not statistically different from each other (F= 1.67, p=0.19) but showed a decreasing trend. In contrast, in the microcalcification study the mean FOM was 0.93, 0.67, and 0.38 for the same dose levels and these values were all significantly different from each other (F = 109.84, p < 0.0001). The results indicate that lowering the present dose level by a factor of two compromised the detection of microcalcifications but had a weaker effect on mass detection.
  •  
4.
  • Timberg, Pontus, et al. (författare)
  • Visibility of microcalcification clusters and masses in breast tomosynthesis image volumes and digital mammography: A 4AFC human observer study
  • 2012
  • Ingår i: Medical Physics. - : Wiley. - 0094-2405. ; 39:5, s. 2431-2437
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To investigate the visibility of simulated lesions in digital breast tomosynthesis (BT) image volumes compared with 2D digital mammography (DM). Methods: Simulated lesions (masses and microcalcifications) were added to images of the same women acquired on a DM system (Mammomat Novation, Siemens) and a BT prototype. The same beam quality was used for the DM and BT acquisitions. The total absorbed dose resulting from a 25-projection BT acquisition and reconstruction (BT25) was approximately twice that of a single DM view. By excluding every other projection image from the reconstruction (BT13), approximately the same dose as in DM was effected. Simulated microcalcifications were digitally added with varying contrast to the DM and BT images. Simulated masses with 8 mm diameter were also added to BT images. A series of 4-alternative forced choice (4AFC) human observer experiments were conducted. Four medical physicists participated in all experiments, each consisting of 60 trials per experimental condition. The observers interpreted the BT image volumes in cine-mode at a fixed image sequence speed. The required threshold contrast (S-t) to achieve a detectability index (d') of 2.5 (i.e., 92.5% correct decisions) was determined. Results: The St for mass detection in DM was approximately a factor of 2 higher than required in BT indicating that the detection of masses was improved under BT conditions compared to DM. St for microcalcification detection was higher for BT than for DM at both BT dose levels (BT25 and BT13), with a statistically significant difference in St between DM and BT13. These results indicate a dose-dependent decrease in detection performance in BT for detection of microcalcifications. Conclusions: In agreement with previous investigations, masses of size 8 mm can be detected with less contrast in BT than in DM indicating improved detection performance for BT. However, for the investigated microcalcifications, the results of this study indicate potentially worse performance for BT than for DM at the same dose level. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.3694105]
  •  
5.
  • Zackrisson, Sophia, et al. (författare)
  • The development of breast radiology : the Acta Radiologica perspective
  • 2021
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 62:11, s. 1473-1480
  • Forskningsöversikt (refereegranskat)abstract
    • The encouraging results of modern breast cancer care builds on tremendous improvements in diagnostics and therapy during the 20th century. Scandinavian countries have made important footprints in the development of breast diagnostics regarding technical development of imaging, cell and tissue sampling methods and, not least, population screening with mammography. The multimodality approach in combination with multidisciplinary clinical work in breast cancer serve as a role model for the management of many cancer types worldwide. The development of breast radiology is well represented in the research published in this journal and this historical review will describe the most important steps.
  •  
6.
  • Förnvik, Daniel, et al. (författare)
  • Pressure distribution in mammography: compression of breasts with malignant tumor masses
  • 2013
  • Ingår i: Medical Imaging 2013: Physics of Medical Imaging. - : SPIE. - 1996-756X .- 0277-786X. ; 8668, s. 86684-86684
  • Konferensbidrag (refereegranskat)abstract
    • The pressure distribution over a compressed breast is in general heterogeneous. In this study we investigated the pressure distribution over compressed breasts with tumor masses. Twenty-two women either recalled for work-up of findings suspicious for breast cancer in the screening program or with clinically suspected findings were included in the study. Twenty-one lesions turned out to be malignant and one benign. The distribution of compression pressure was measured using thin FSR (Force Sensing Resistor) pressure sensors attached to the compression plate. The pressure over the breast was ascertained by acquiring an x-ray image of the compressed breast with the pressure sensors present. The pressure data and the mammogram were used to create a composite image with pressure data displayed as a color overlay. The malignant tumor area generally matched an elevated pressure area and this pressure was generally higher than the pressure over surrounding parenchyma. In 11 out of 22 (50%) subjects the maximum pressure over the breast was located over the tumor. Only 4 out of 22 (18%) masses had a lower tumor mean pressure compared to the mean pressure over the breast (including one small < 10 mm tumor and one benign structure). The results suggest that tumors are stiffer, thus, absorbing more pressure compared to the surrounding parenchyma and that this property can be quantified. Refined pressure techniques could possibly be used to demonstrate the relative elasticity distribution in breast tissue, which might provide valuable differential diagnostic information.
  •  
7.
  • Hemdal, Bengt, et al. (författare)
  • Clinical evaluation of a new set of image quality criteria for mammography.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 389-94
  • Tidskriftsartikel (refereegranskat)abstract
    • The European Commission (EC) quality criteria for screen-film mammography are used as a tool to assess image quality. A new set of criteria was developed and initially tested in a previous study. In the present study, these criteria are further evaluated using screen-film mammograms that have been digitised, manipulated to simulate different image quality levels and reprinted on film. Expert radiologists have evaluated these manipulated images using both the original (EC) and the new criteria. A comparison of three different simulated dose levels reveals that the new criteria yield a larger separation of image criteria scores than the old ones. These results indicate that the new set of image quality criteria has a higher discriminative power than the old set and thus seems to be more suitable for evaluation of image quality in mammography.
  •  
8.
  • Nyström, Lennarth, et al. (författare)
  • Long-term effects of mammography screening : Updated overview of the Swedish randomised trials
  • 2002
  • Ingår i: The Lancet. - 0140-6736 .- 1474-547X. ; 359:9310, s. 909-919
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: There has been much debate about the value of screening mammography. Here we update the overview of the Swedish randomised controlled trials on mammography screening up to and including 1996. The Kopparberg part of the Two-County trial was not available for the overview, but the continuation of the Malm÷ trial (MMST II) has been added. The article also contains basic data from the trials that have not been presented before. Methods: The trials (n=247 010, invited group 129 750, control group 117 260) have been followed up by record linkage to the Swedish Cancer and Cause of Death Registers. The relative risks (RR) for breast cancer death and mortality were calculated for the invited and the control groups. The trial-specific as well as the age-specific effects were analysed. RRs were calculated by the density method, with total person-time experience of the cohort by time interval of follow-up as a basis for estimating mortality rates. We calculated weighted RRs and 95% CI with the Mantel-Haenszel procedure. Findings: The median trial time - the time from randomisation until the first round was completed for the control group or if the control group was not invited, until end of follow-up - was 6.5 years (range 3.0-18.1). The median follow-up time, the time from randomisation, to the end of follow-up, was 15.8 years (5.8-20.2). There were 511 breast cancer deaths in 1 864 770 women-years in the invited groups and 584 breast cancer deaths in 1 688 440 women-years in the control groups, a significant 21% reduction in breast cancer mortality (RR=0.79, 95% CI 0.70-0.89). The reduction was greatest in the age group 60-69 years at entry (33%). Looking at 5-year age groups, there were statistically significant effects in the age groups 55-59, 60-64, and 65-69 years (RR=0.76, 0.68, and 0.69, respectively). There was a small effect in women 50-54 years at randomisation (RR=0.95). The benefit in terms of cumulative breast cancer mortality started to emerge at about 4 years after randomisation and continued to increase to about 10 years. Thereafter the benefit in absolute terms was maintained throughout the period of observation. The age-adjusted relative risk for the total mortality was 0.98 (0.96-1.00). Interpretation: The advantageous effect of breast screening on breast cancer mortality persists after long-term follow-up. The recent criticism against the Swedish randomised controlled trials is misleading and scientifically unfounded.
  •  
9.
  • Johnson, Kristin, et al. (författare)
  • Interval breast cancer rates and tumor characteristics in the prospective population-based Malmö breast tomosynthesis screening trial
  • 2021
  • Ingår i: Radiology. - : Radiological Society of North America (RSNA). - 0033-8419 .- 1527-1315. ; 299:3, s. 559-567
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Interval cancer rates can be used to evaluate whether screening with digital breast tomosynthesis (DBT) contributes to a screening benefit. Purpose: To compare interval cancer rates and tumor characteristics in DBT screening to those in a contemporary population screened with digital mammography (DM). Materials and Methods: The prospective population-based Malmö Breast Tomosynthesis Screening Trial (MBTST) was designed to compare one-view DBT to two-view DM in breast cancer detection. The interval cancer rates and cancer characteristics in the MBTST were compared with an age-matched contemporary control group, screened with two-view DM at the same center. Conditional logistic regression was used for data analysis. Results: There were 14 848 women who were screened with DBT and DM in the MBTST between January 2010 and February 2015. The trial women were matched with two women of the same age and screening occasion at DM screening during the same period. Matches for 13 369 trial women (mean age, 56 years ± 10 [standard deviation]) were found with 26 738 women in the control group (mean age, 56 years ± 10). The interval cancer rate in the MBTST was 1.6 per 1000 screened women (21 of 13 369; 95% CI: 1.0, 2.4) compared with 2.8 per 1000 screened women in the control group (76 of 26 738 [95% CI: 2.2, 3.6]; conditional odds ratio, 0.6 [95% CI: 0.3, 0.9]; P = .02). The invasive interval cancers in the MBTST and in the control group showed in general high Ki-67 (63% [12 of 19] and 75% [54 of 72]), and low proportions of luminal A–like subtype (26% [five of 19] and 17% [12 of 72]), respectively. Conclusion: The reduced interval cancer rate after screening with digital breast tomosynthesis compared with a contemporary age-matched control group screened with digital mammography might translate into screening benefits. Interval cancers in the trial generally had nonfavorable characteristics.
  •  
10.
  • Johnson, Kristin, et al. (författare)
  • Tumor Characteristics and Molecular Subtypes in Breast Cancer Screening with Digital Breast Tomosynthesis : The Malmö Breast Tomosynthesis Screening Trial
  • 2019
  • Ingår i: Radiology. - : Radiological Society of North America (RSNA). - 1527-1315 .- 0033-8419. ; 293:2, s. 273-281
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Screening accuracy can be improved with digital breast tomosynthesis (DBT). To further evaluate DBT in screening, it is important to assess the molecular subtypes of the detected cancers. Purpose To describe tumor characteristics, including molecular subtypes, of cancers detected at DBT compared with those detected at digital mammography (DM) in breast cancer screening. Materials and Methods The Malmö Breast Tomosynthesis Screening Trial is a prospective, population-based screening trial comparing one-view DBT with two-view DM. Tumor characteristics were obtained, and invasive cancers were classified according to St Gallen as follows: luminal A-like, luminal B-like human epidermal growth factor receptor (HER)2-negative/HER2-positive, HER2-positive, and triple-negative cancers. Tumor characteristics were compared by mode of detection: DBT alone or DM (ie, DBT and DM or DM alone). χ2 test was used for data analysis. Results Between January 2010 and February 2015, 14 848 women were enrolled (mean age, 57 years ± 10; age range, 40-76 years). In total, 139 cancers were detected; 118 cancers were invasive and 21 were ductal carcinomas in situ. Thirty-seven additional invasive cancers (36 cancers with complete subtypes and stage) were detected at DBT alone, and 81 cancers (80 cancers with complete stage) were detected at DM. No differences were seen between DBT and DM in the distribution of tumor size 20 mm or smaller (86% [31 of 36] vs 85% [68 of 80], respectively; P = .88), node-negative status (75% [27 of 36] vs 74% [59 of 80], respectively; P = .89), or luminal A-like subtype (53% [19 of 36] vs 46% [37 of 81], respectively; P = .48). Conclusion The biologic profile of the additional cancers detected at digital breast tomosynthesis in a large prospective population-based screening trial was similar to those detected at digital mammography, and the majority were early-stage luminal A-like cancers. This indicates that digital breast tomosynthesis screening does not alter the predictive and prognostic profile of screening-detected cancers.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 61

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy