1.
  • Svalkvist, Angelica, et al. (författare)
  • VIEWDEX 3.0-RECENT DEVELOPMENT OF A SOFTWARE APPLICATION FACILITATING ASSESSMENT OF IMAGE QUALITY AND OBSERVER PERFORMANCE
  • 2021
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 195:3-4, s. 372-377
  • Tidskriftsartikel (refereegranskat)abstract
    • ViewDEX (Viewer for Digital Evaluation of X-ray Images) is an image viewer compatible with Digital Imaging and Communications in Medicine (DICOM) that has been especially designed to facilitate image perception and observer performance studies within medical imaging. The software was first released in 2004 and since then a continuous development has been ongoing. One of the major drawbacks of previous versions of ViewDEX has been that they have lacked functionality enabling the possibility to evaluate multiple images and/or image stacks simultaneously. This functionality is especially requested by researchers working with modalities, where an image acquisition can result in multiple image stacks (e.g. axial, coronal and sagittal reformations in computed tomography). In ViewDEX 3.0 this functionality has been added and it is now possible to perform image evaluations of multiple images and/or image stacks simultaneously, by using multiple monitors and/or multiple image canvases in monitors. Additionally, some of the previously available functionality has been updated and improved. This paper describes the recent developments of ViewDEX 3.0.
  •  
2.
  • Visanuyanont, T., et al. (författare)
  • AUTOMATED QC FOR INTERVENTIONAL SYSTEMS AND MAMMOGRAPHY SYSTEMS
  • 2021
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 195:3-4, s. 399-406
  • Tidskriftsartikel (refereegranskat)abstract
    • Quality control (QC) of X-ray equipment is an important task for patient safety. Periodic QC should not take long to perform, especially in a stressful clinical environment where downtime should be minimised. DOSESTAT-QC (R) is a new quick QC software with automatic image analysis that has been developed into a quality-assured and user-friendly tool for daily use. Trained X-ray personnel can easily perform the QC with selected image phantoms and immediately approve the results onsite before the equipment is used clinically. Image analysis includes visibility of contrast detail groups, homogeneity, signal-to-noise ratio and contrast-to-noise ratio. In the event of unapproved QC, a message is automatically sent to medical physicists and/or medical engineers. The results are stored over time and are available for trend analysis. The present paper describes the DOSESTAT-QC (R) software and its application in QC of interventional X-ray systems and mammography systems.
  •  
3.
  • Ludwigs, Karin, et al. (författare)
  • Poor inter-observer agreement in anatomical classifications of infrapopliteal arterial disease due to mandatory selection of only one target artery
  • 2023
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 64:3, s. 1298-1306
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Established anatomical classifications of infrapopliteal arterial lesion severity are based on assessment of only one target artery, not including all infrapopliteal arteries although multivessel revascularization is common. Purpose To investigate the reproducibility of one of these classifications and a new aggregated score. Material and Methods A total of 68 patients undergoing endovascular infrapopliteal revascularization at Sahlgrenska University Hospital during 2008-2016 were included. Preoperative magnetic resonance angiographies (MRA) and digital subtraction angiographies (DSA) were evaluated by three blinded observers in random order, using the infrapopliteal TransAtlantic Inter-Society Consensus (TASC) II classification. An aggregated score, the Infrapopliteal Total Atherosclerotic Burden (I-TAB) score, including all infrapopliteal arteries, was constructed and used for comparison. Results Inter-observer agreement on lesion severity for each evaluated artery was good; Krippendorff's alpha for MRA 0.64-0.79 and DSA 0.66-0.84. Inter-observer agreement on TASC II grade, based on the selected target artery as stipulated, was poor; Krippendorff's alpha 0.14 (95% confidence interval [CI]=-0.05 to 0.30) for MRA and 0.48 (95% CI=0.33-0.61) for DSA. Inter-observer agreement for the new I-TAB score was good; Krippendorff's alpha 0.76 (95% CI=0.70-0.81) for MRA and 0.79 (95% CI=0.74-0.84) for DSA. Conclusion Reproducible assessment of infrapopliteal lesion severity can be achieved for separate arteries with both MRA and DSA using the TASC II definitions. However, poor inter-observer agreement in selecting the target artery results in low reproducibility of the overall infrapopliteal TASC II grade. An aggregated score, such as I-TAB, results in less variability and may provide a more robust evaluation tool of atherosclerotic disease severity.
  •  
4.
  • Asplund, Sara, 1976, et al. (författare)
  • Learning aspects and potential pitfalls regarding detection of pulmonary nodules in chest tomosynthesis and proposed related quality criteria.
  • 2011
  • Ingår i: Acta radiologica. - : SAGE Publications. - 1600-0455 .- 0284-1851. ; 52:5, s. 503-512
  • Tidskriftsartikel (refereegranskat)abstract
    • Background In chest tomosynthesis, low-dose projections collected over a limited angular range are used for reconstruction of an arbitrary number of section images of the chest, resulting in a moderately increased radiation dose compared to chest radiography. Purpose To investigate the effects of learning with feedback on the detection of pulmonary nodules for observers with varying experience of chest tomosynthesis, to identify pitfalls regarding detection of pulmonary nodules, and present suggestions for how to avoid them, and to adapt the European quality criteria for chest radiography and computed tomography (CT) to chest tomosynthesis. Material and Methods Six observers analyzed tomosynthesis cases for presence of nodules in a jackknife alternative free-response receiver-operating characteristics (JAFROC) study. CT was used as reference. The same tomosynthesis cases were analyzed before and after learning with feedback, which included a collective learning session. The difference in performance between the two readings was calculated using the JAFROC figure of merit as principal measure of detectability. Results Significant improvement in performance after learning with feedback was found only for observers inexperienced in tomosynthesis. At the collective learning session, localization of pleural and subpleural nodules or structures was identified as the main difficulty in analyzing tomosynthesis images. Conclusion The results indicate that inexperienced observers can reach a high level of performance regarding nodule detection in tomosynthesis after learning with feedback and that the main problem with chest tomosynthesis is related to the limited depth resolution.
  •  
5.
  • Svalkvist, Angelica, et al. (författare)
  • Evaluation of an improved method of simulating lung nodules in chest tomosynthesis
  • 2012
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 53:8, s. 874-884
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Simulated pathology is a valuable complement to clinical images in studies aiming at evaluating an imaging technique. In order for a study using simulated pathology to be valid, it is important that the simulated pathology in a realistic way reflect the characteristics of real pathology. Purpose: To perform a thorough evaluation of a nodule simulation method for chest tomosynthesis, comparing the detection rate and appearance of the artificial nodules with those of real nodules in an observer performance experiment. Material and Methods: A cohort consisting of 64 patients, 38 patients with a total of 129 identified pulmonary nodules and 26 patients without identified pulmonary nodules, was used in the study. Simulated nodules, matching the real clinically found pulmonary nodules by size, attenuation, and location, were created and randomly inserted into the tomosynthesis section images of the patients. Three thoracic radiologists and one radiology resident reviewed the images in an observer performance study divided into two parts. The first part included nodule detection and the second part included rating of the visual appearance of the nodules. The results were evaluated using a modified receiver-operating characteristic (ROC) analysis. Results: The sensitivities for real and simulated nodules were comparable, as the area under the modified ROC curve (AUC) was close to 0.5 for all observers (range, 0.43-0.55). Even though the ratings of visual appearance for real and simulated nodules overlapped considerably, the statistical analysis revealed that the observers to were able to separate simulated nodules from real nodules (AUC values range 0.70-0.74). Conclusion: The simulation method can be used to create artificial lung nodules that have similar detectability as real nodules in chest tomosynthesis, although experienced thoracic radiologists may be able to distinguish them from real nodules.
  •  
6.
  • Svalkvist, Angelica, et al. (författare)
  • Comparison of different approaches of estimating effective dose from reported exposure data in 3D imaging with interventional fluoroscopy systems
  • 2014
  • Ingår i: SPIE Medical Imaging 2014, 15-20 February 2014, San Diego, California, USA. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. - : SPIE. - 1605-7422. ; 9033
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • Three-dimensional (3D) imaging with interventional fluoroscopy systems is today a common examination. The examination includes acquisition of two-dimensional projection images, used to reconstruct section images of the patient. The aim of the present study was to investigate the difference in resulting effective dose obtained using different levels of complexity in calculations of effective doses from these examinations. In the study the Siemens Artis Zeego interventional fluoroscopy system (Siemens Medical Solutions, Erlangen, Germany) was used. Images of anthropomorphic chest and pelvis phantoms were acquired. The exposure values obtained were used to calculate the resulting effective doses from the examinations, using the computer software PCXMC (STUK, Helsinki, Finland). The dose calculations were performed using three different methods: 1. using individual exposure values for each projection image, 2. using the mean tube voltage and the total DAP value, evenly distributed over the projection images, and 3. using the mean kV and the total DAP value, evenly distributed over smaller selection of projection images. The results revealed that the difference in resulting effective dose between the first two methods was smaller than 5%. When only a selection of projection images were used in the dose calculations the difference increased to over 10%. Given the uncertainties associated with the effective dose concept, the results indicate that dose calculations based on average exposure values distributed over a smaller selection of projection angles can provide reasonably accurate estimations of the radiation doses from 3D imaging using interventional fluoroscopy systems. © 2014 SPIE.
  •  
7.
  • Johnsson, Åse (Allansdotter), 1966, et al. (författare)
  • A phantom study of nodule size evaluation with chest tomosynthesis and computed tomography.
  • 2010
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 139:1-3, s. 140-143
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of the present study was to investigate nodule size measurements with chest tomosynthesis (TS) and computed tomography (CT). A 26-mm thick phantom, composed of a Polylite block with embedded spheres of different materials and sizes (4-20 mm), was scanned by both CT and TS. Six observers without prior knowledge of the true diameters of the spheres independently measured the diameter of the spheres on the CT and TS images. Four observers were allowed to change the window settings and two of the observers used predetermined fixed viewing conditions. The mean relative errors for all observers and all measured spheres compared with the known diameter of the spheres were 1.4 % (standard deviation, SD: 5.4 %) on CT images and -1.1 % (SD: 5.0 %) on TS images. With regard to the four observers where the window settings were at the discretion of the observer, the mean relative errors were 1.4 % (SD: 6.4 %) on CT images and -1.7 % (SD: 5.7 %) on TS images. Regarding the two observers using identical viewing conditions the mean relative error was 1.5 % (SD: 2.8 %) on CT images and 0.2 % (SD: 2.6 %) on TS images. In conclusion, the study suggests that nodule size measurements on chest TS might be an alternative to measurements on CT.
  •  
8.
  • Zachrisson, Sara, et al. (författare)
  • Effect of clinical experience of chest tomosynthesis on detection of pulmonary nodules.
  • 2009
  • Ingår i: Acta radiologica. - : SAGE Publications. - 1600-0455 .- 0284-1851. ; 50:8, s. 884-891
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The new technique chest tomosynthesis refers to the principle of collecting low-dose projections of the chest at different angles and using these projections to reconstruct section images of the chest at a radiation dose comparable to that of chest radiography. PURPOSE: To investigate if, for experienced thoracic radiologists, the detectability of pulmonary nodules obtained after only a short initial learning period of chest tomosynthesis improves with additional clinical experience of the new technique. MATERIAL AND METHODS: Two readings of the same clinical chest tomosynthesis cases, the first performed after 6 months of clinical experience and the second after an additional period of 1 year, were conducted. Three senior thoracic radiologists, with more than 20 years of experience of chest radiography, acted as observers, with the task of detecting pulmonary nodules in a jackknife free-response receiver operating characteristics (JAFROC1) study. The image material consisted of 42 patients with and 47 patients without pulmonary nodules examined with chest tomosynthesis. Multidetector computed tomography (MDCT) was used as a reference. The total number of nodules was 131. The JAFROC1 figure of merit (FOM) was used as the principal measure of detectability. RESULTS: The difference in the observer-averaged JAFROC1 FOM of the two readings was 0.004 (95% confidence interval: -0.11, 0.12; F-statistic: 0.01 on 1 and 2.65 df; P=0.91). Thus, no significant improvement in detectability was found after the additional clinical experience of tomosynthesis. CONCLUSION: The study indicates that experienced thoracic radiologists already within the first months of clinical use of chest tomosynthesis are able to take advantage of the new technique in the task of detecting pulmonary nodules.
  •  
9.
  • Asplund, Sara, 1976, et al. (författare)
  • Extended analysis of the effect of learning with feedback on the detectability of pulmonary nodules in chest tomosynthesis
  • 2011
  • Ingår i: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. - : SPIE. - 1605-7422. ; 7966
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • In chest tomosynthesis, low-dose projections collected over a limited angular range are used for reconstruction of section images of the chest, resulting in a reduction of disturbing anatomy at a moderate increase in radiation dose compared to chest radiography. In a previous study, we investigated the effects of learning with feedback on the detection of pulmonary nodules in chest tomosynthesis. Six observers with varying degrees of experience of chest tomosynthesis analyzed tomosynthesis cases for presence of pulmonary nodules. The cases were analyzed before and after learning with feedback. Multidetector computed tomography (MDCT) was used as reference. The differences in performance between the two readings were calculated using the jackknife alternative free-response receiver operating characteristics (JAFROC-2) as primary measure of detectability. Significant differences between the readings were found only for observers inexperienced in chest tomosynthesis. The purpose of the present study was to extend the statistical analysis of the results of the previous study, including JAFROC-1 analysis and FROC curves in the analysis. The results are consistent with the results of the previous study and, furthermore, JAFROC-1 gave lower p-values than JAFROC-2 for the observers who improved their performance after learning with feedback. © 2011 SPIE.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 72
Typ av publikation
tidskriftsartikel (37)
konferensbidrag (35)
Typ av innehåll
övrigt vetenskapligt/konstnärligt (40)
refereegranskat (32)
Författare/redaktör
Båth, Magnus, 1974 (68)
Månsson, Lars Gunnar ... (38)
Johnsson, Åse (Allan ... (36)
Vikgren, Jenny, 1957 (33)
Söderman, Christina (19)
visa fler...
Flinck, Agneta, 1953 (19)
Boijsen, Marianne, 1 ... (19)
Zachrisson, Sara (19)
Kheddache, Susanne, ... (17)
Rossi-Norrlund, Raun ... (14)
Molnar, David (13)
Håkansson, Markus (11)
Asplund, Sara, 1976 (7)
Fisichella, Valeria ... (7)
Ullman, Gustaf (7)
Svensson, Sune (7)
Rystedt, Hans, 1951 (4)
Alm Carlsson, Gudrun (4)
Ivarsson, Jonas, 197 ... (4)
Sandborg, Michael (3)
Wiksell, Åsa (3)
Hansson, Jonny (3)
Svensson, S (2)
Nordanstig, Joakim (2)
von Wrangel, Alexa, ... (2)
Falkenberg, Mårten, ... (2)
Andersson, Manne (2)
Ludwigs, Karin (2)
Rismyhr-Olsson, Heid ... (2)
Cederblad, Åke, 1947 (2)
Mattsson, Sören (1)
Arvidsson, Jonathan (1)
Gottfridsson, B (1)
Hakansson, M (1)
Chodorowski, Artur, ... (1)
Sandborg, Michael, 1 ... (1)
Baubeta, Erik (1)
Wiksell, Asa (1)
Moberg, T. (1)
Fagman, Erika (1)
Baubeta Fridh, Erik (1)
Bernhardt, Peter (1)
Ceder, Erik (1)
Båth, Magnus (1)
Michael Moores, B. (1)
Danielson, Barbro (1)
Kovàč, Peter (1)
Fogel, Hanna (1)
Dance, David (1)
visa färre...
Lärosäte
Göteborgs universitet (71)
Linköpings universitet (6)
Lunds universitet (3)
Uppsala universitet (1)
Chalmers tekniska högskola (1)
Språk
Engelska (69)
Svenska (3)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (72)
Teknik (5)
Samhällsvetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy