SwePub
Sök i SwePub databas

  Utökad sökning

AND är defaultoperator och kan utelämnas

Träfflista för sökning "AMNE:(MEDICAL AND HEALTH SCIENCES Medical Biotechnology Other Medical Biotechnology) ;lar1:(hig)"

Sökning: AMNE:(MEDICAL AND HEALTH SCIENCES Medical Biotechnology Other Medical Biotechnology) > Högskolan i Gävle

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Hadrevi, Jenny, et al. (författare)
  • Myosin light chain and calcium regulating protein differences in chronic musculoskeletal neck and shoulder pain
  • 2016
  • Ingår i: Journal of Integrated Omnics. - : Proteomass Scientific Society. - 2182-0287. ; 6:1, s. 1-8
  • Tidskriftsartikel (refereegranskat)abstract
    • Proteomic screening analysis has detected myosin light chain (MLC) as a protein implied to be involved in chronic musculoskeletal neck and shoulder pain. Several analyses of MLC proteins have stated a difference in phosphorylation being the determining factor for protein activation hence altered contrability of the muscle in i.e. senescence. In continuation of a previous publication, this study is an attempt to analyze the different MLC isoforms by mass spectrometry and immune-analyses in myalgic and healthy trapezius muscle. In the present study no differences in phosphorylation level between the corresponding individual proteins were detected using LC-MSMS and immunoblotting; instead we assigned different isoforms of regulatory MLCs. To further elucidate the contrability: calcium (Ca2+) regulatory proteins, sarco(endo)plasmic reticulum Ca2+ ATPase 1 (SERCA-1) and calsequestrine (CSQ) were analyzed by western blot. The analysis revealed a significantly increased abundance of SERCA-1 protein in the myalgic muscle and a significantly increased abundance of CSQ in healthy muscle. Myalgic muscle contraction patterns have in previous studies shown to differ from healthy muscle which may be connected to the Ca2+ availability in the muscle. Here we present the proteomic characterization of differences in Ca2+ regulating proteins and particularly regulatory MLCs in trapezius muscle of women with chronic musculoskeletal neck and shoulder pain.
  •  
2.
  • Hellström, Fredrik, et al. (författare)
  • Association between plasma concentrations of linoleic acid-derived oxylipins and the perceived pain scores in an exploratory study in women with chronic neck pain
  • 2016
  • Ingår i: BMC Musculoskeletal Disorders. - : Springer Science and Business Media LLC. - 1471-2474. ; 17
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Chronic musculoskeletal pain may be associated with changes in the balance of algogenic and anti-nociceptive compounds, and such changes may be visible in plasma samples. We have undertaken an exploratory study to measure the levels of endocannabinoids, related N-acylethanolamines and oxylipins (primarily those derived from linoleic acid) in plasma samples from women with chronic neck pain (NP) and chronic widespread pain (CWP), and to investigate whether the observed levels are associated with the pain experienced by these women.Methods: Blood samples from 35 women with NP, 15 with CWP and 27 age-matched controls were analysed for the lipids using ultra performance liquid chromatography coupled to tandem mass spectrometry. Current pain (“NRSday”) and the average pain during the last week (“NRSweek”) were rated by the participants using a numerical rating scale.Results: There were no significant differences in the plasma concentrations of the fifteen lipids investigated between the women with pain and the controls. However, significant correlations were seen for the NP group between the NRSday scores and the plasma concentrations of the linoleic acid derivatives 9- and 13-hydroxy-octadecadienoic acid (Spearman’s rho values 0.51 [P = 0.0016]) and 0.53 [P = 0.0011], respectively).Conclusions: The data obtained in this exploratory study indicate that although no group differences are seen in plasma lipid concentrations, there is an association between the NRSday scores and the 9- and 13-hydroxy-octadecadienoic acid levels. Whether or not the association reflects a causality (i.e. that the circulating lipids contribute to the perceived pain of the pain participants), requires further investigation.
  •  
3.
  • Chang, Keke, et al. (författare)
  • Considerations on Circuit Design and Data Acquisition of a Portable Surface Plasmon Resonance Biosensing System
  • 2015
  • Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 15:8, s. 20511-20523
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to develop a circuit for an inexpensive portable biosensing system based on surface plasmon resonance spectroscopy. This portable biosensing system designed for field use is characterized by a special structure which consists of a microfluidic cell incorporating a right angle prism functionalized with a biomolecular identification membrane, a laser line generator and a data acquisition circuit board. The data structure, data memory capacity and a line charge-coupled device (CCD) array with a driving circuit for collecting the photoelectric signals are intensively focused on and the high performance analog-to-digital (A/D) converter is comprehensively evaluated. The interface circuit and the photoelectric signal amplifier circuit are first studied to obtain the weak signals from the line CCD array in this experiment. Quantitative measurements for validating the sensitivity of the biosensing system were implemented using ethanol solutions of various concentrations indicated by volume fractions of 5%, 8%, 15%, 20%, 25%, and 30%, respectively, without a biomembrane immobilized on the surface of the SPR sensor. The experiments demonstrated that it is possible to detect a change in the refractive index of an ethanol solution with a sensitivity of 4.99838 × 10(5) ΔRU/RI in terms of the changes in delta response unit with refractive index using this SPR biosensing system, whereby the theoretical limit of detection of 3.3537 × 10(-5) refractive index unit (RIU) and a high linearity at the correlation coefficient of 0.98065. The results obtained from a series of tests confirmed the practicality of this cost-effective portable SPR biosensing system.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy