SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

AND är defaultoperator och kan utelämnas

Träfflista för sökning "AMNE:(MEDICAL AND HEALTH SCIENCES Medical Biotechnology Other Medical Biotechnology) ;pers:(Jurvelin Jukka)"

Sökning: AMNE:(MEDICAL AND HEALTH SCIENCES Medical Biotechnology Other Medical Biotechnology) > Jurvelin Jukka

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Rieppo, Lassi, et al. (författare)
  • Quantitative analysis of spatial proteoglycan content in articular cartilage with Fourier transform infrared imaging spectroscopy : Critical evaluation of analysis methods and specificity of the parameters.
  • 2010
  • Ingår i: Microscopy research and technique (Print). - : John Wiley & Sons. - 1059-910X .- 1097-0029. ; 73:5, s. 503-512
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To evaluate the specificity of the current Fourier transform infrared imaging spectroscopy (FT-IRIS) methods for the determination of depthwise proteoglycan (PG) content in articular cartilage (AC). In addition, curve fitting was applied to study whether the specificity of FT-IRIS parameters for PG determination could be improved.METHODS: Two sample groups from the steer AC were prepared for the study (n = 8 samples/group). In the first group, chondroitinase ABC enzyme was used to degrade the PGs from the superficial cartilage, while the samples in the second group served as the controls. Samples were examined with FT-IRIS and analyzed using previously reported direct absorption spectrum techniques and multivariate methods and, in comparison, by curve fitting. Safranin O-stained sections were measured with digital densitometry to obtain a reference for depthwise PG distribution.RESULTS: Carbohydrate region-based absorption spectrum methods showed a statistically weaker correlation with the PG reference distributions than the results of the curve fitting (subpeak located approximately at 1,060 cm(-1)). Furthermore, the shape of the depthwise profiles obtained using the curve fitting was more similar to the reference profiles than with the direct absorption spectrum analysis.CONCLUSIONS: Results suggest that the current FT-IRIS methods for PG analysis lack the specificity for quantitative measurement of PGs in AC. The curve fitting approach demonstrated that it is possible to improve the specificity of the PG analysis. However, the findings of the present study suggest that further development of the FT-IRIS analysis techniques is still needed.
  •  
2.
  • Sierpowska, Joanna, et al. (författare)
  • Effect of human trabecular bone composition on its electrical properties.
  • 2007
  • Ingår i: Medical Engineering and Physics. - : Elsevier. - 1350-4533 .- 1873-4030. ; 29:8, s. 845-852
  • Tidskriftsartikel (refereegranskat)abstract
    • Mechanical properties of bone are determined not only by bone mineral density (BMD), but also by tissue trabecular structure and organic composition. Impedance spectroscopy has shown potential to diagnose trabecular bone BMD and strength, however, the relationships between organic composition and electrical and dielectric properties have not been systematically investigated. To investigate these issues organic composition of 26 human trabecular bone samples harvested from the distal femur and proximal tibia was determined and compared with relative permittivity, loss factor, conductivity, phase angle, specific impedance and dissipation factor measured at wide range (50 Hz to 5 MHz) of frequencies. A strong linear correlation was found between the relative permittivity at 1.2 MHz and trabecular bone fat content (r = -0.85, p<0.01, n=26). On the other hand, relative permittivity measured at 200 Hz served as a good predictor of water content (r = 0.83). Phase angle, specific impedance and especially conductivity were strongly related to the trabecular bone dry density and water content (|r| > or = 0.69). Variation in bone tissue collagen content was strongly related to the relative permittivity measured at 1.2 MHz (r = 0.64), but only moderately to other parameters. Glycosaminoglycan content showed no significant relations with any investigated electrical parameters. The present study indicates that if the trabecular bone composition is known, the relationships presented in this study could facilitate calculation of current field distribution, e.g. during electrical stimulation of osteogenesis. On the other hand, our results suggest that permittivity measured at low (<1 kHz) or high (>100 kHz) frequencies could be used, e.g. during implant surgery, for prediction of trabecular bone water or fat contents, respectively.
  •  
3.
  • Honkanen, Juuso, et al. (författare)
  • Cationic contrast agent diffusion differs between cartilage and meniscus
  • 2016
  • Ingår i: Annals of Biomedical Engineering. - : Springer. - 0090-6964 .- 1573-9686. ; 44:10, s. 2913-2921
  • Tidskriftsartikel (refereegranskat)abstract
    • Contrast enhanced computed tomography (CECT) is a non-destructive imaging technique used for the assessment of composition and structure of articular cartilage and meniscus. Due to structural and compositional differences between these tissues, diffusion and distribution of contrast agents may differ in cartilage and meniscus. The aim of this study is to determine the diffusion kinematics of a novel iodine based cationic contrast agent (CA(2+)) in cartilage and meniscus. Cylindrical cartilage and meniscus samples (d = 6 mm, h ≈ 2 mm) were harvested from healthy bovine knee joints (n = 10), immersed in isotonic cationic contrast agent (20 mgI/mL), and imaged using a micro-CT scanner at 26 time points up to 48 h. Subsequently, normalized X-ray attenuation and contrast agent diffusion flux, as well as water, collagen and proteoglycan (PG) contents in the tissues were determined. The contrast agent distributions within cartilage and meniscus were different. In addition, the normalized attenuation and diffusion flux were higher (p < 0.05) in cartilage. Based on these results, diffusion kinematics vary between cartilage and meniscus. These tissue specific variations can affect the interpretation of CECT images and should be considered when cartilage and meniscus are assessed simultaneously.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy