SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "AMNE:(MEDICIN OCH HÄLSOVETENSKAP Klinisk medicin Radiologi och bildbehandling) ;pers:(Noz Marilyn E.)"

Sökning: AMNE:(MEDICIN OCH HÄLSOVETENSKAP Klinisk medicin Radiologi och bildbehandling) > Noz Marilyn E.

  • Resultat 1-10 av 126
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Olivecrona, Henrik, et al. (författare)
  • A new computed tomography-based radiographic method to detect early loosening of total wrist implants
  • 2007
  • Ingår i: Acta Radiologica. - London, UK : Informa Healthcare. - 0284-1851 .- 1600-0455. ; 48:9, s. 997-1003
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Diagnosis of loosening of total wrist implants is usually late using routine radiographs. Switching modality to computed tomography (CT) should aid in early diagnosis. Purpose: To propose and evaluate the accuracy of a new CT method for assessing loosening of the carpal component in total wrist arthroplasty. Material and Methods: A protocol encompassing volume registration of paired CT scans of patients with unexplained pain in a prosthetically replaced wrist (used in clinical routine) is presented. Scans are acquired as a dynamic examination under torsional load. Using volume registration, the carpal component of the prosthesis is brought into spatial alignment. After registration, prosthetic loosening is diagnosed by a shift in position of the bones relative to the prosthesis. This study is a preclinical validation of this method using a human cadaverous arm with a cemented total wrist implant and tantalum markers. Seven CT scans of the arm were acquired. The scans were combined into 21 pairs of CT volumes. The carpal component was registered in each scan pair, and the residual mismatch of the surrounding tantalum markers and bone was analyzed both visually and numerically. Results: The detection limit for prosthetic movement was less than 1 mm. Conclusion: The results of this study demonstrate that CT volume registration holds promise to improve detection of movement of the carpal component at an earlier stage than is obtainable with plain radiography.
  •  
2.
  • Dewyngaert, J. Keith, et al. (författare)
  • Procedure for unmasking localization information from ProstaScint scans for prostate radiation therapy treatment planning
  • 2004
  • Ingår i: International Journal of Radiation Oncology, Biology, Physics. - : Elsevier BV. - 0360-3016 .- 1879-355X. ; 60:2, s. 654-662
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To demonstrate a method to extract the meaningful biologic information from In-111-radiolabeled capromab pendetide (ProstaScint) SPECT scans for use in radiation therapy treatment planning by removing that component of the In-111 SPECT images associated with normal structures. Methods and Materials: We examined 20 of more than 80 patients who underwent simultaneous Tc-99m/In-111 SPECT scans, which were subsequently registered to the corresponding CT/MRI scans. A thresholding algorithm was used to identify Tc-99m uptake associated with blood vessels and CT electron density associated with bone marrow. Corresponding voxels were removed from the In-111 image set. Results: No single threshold value was found to be associated with the Tc-99m uptake that corresponded to the blood vessels. Intensity values were normalized to a global maximum and, as such, were dependent upon the quantity of Tc-99m pooled in the bladder. The reduced ProstaScint volume sets were segmented by use of a thresholding feature of the planning system and superimposed on the CT/MRI scans. Conclusions: ProstaScint images are now closer to becoming a biologically and therapeutically useful and accurate image set. After known sources of normal intensity are stripped away, the remaining areas that demonstrate uptake may be segmented and superimposed on the treatment-planning CT/MRI volume.
  •  
3.
  • Ericson, Anne, et al. (författare)
  • Fusion of radio stereometric analysis data into computed tomography space : Application to the elbow joint
  • 2007
  • Ingår i: Journal of Biomechanics. - Oxford, UK : Elsevier Science Ltd. - 0021-9290 .- 1873-2380. ; 40:2, s. 296-304
  • Tidskriftsartikel (refereegranskat)abstract
    • Improvement of joint prostheses is dependent upon information concerning the biomechanical properties of the joint. Radiostereometric analysis (RSA) and electromagnetic techniques have been applied in previous cadaver and in vivo studies on the elbow joint to provide valuable information concerning joint motion axes. However, such information is limited to mathematically calculated positions of the axes according to an orthogonal coordinate system and is difficult to relate to individual skeletal anatomy. The aim of this study was to evaluate the in vivo application of a new fusion method to provide three-dimensional (31)) visualization of flexion axes according to bony landmarks. In vivo RSA data of the elbow joint's flexion axes was combined with data obtained by 3D computed tomography (CT). Results were obtained from five healthy subjects after one was excluded due to an instable RSA marker. The median error between imported and transformed RSA marker coordinates and those obtained in the CT volume was 0.22mm. Median maximal rotation error after transformation of the rigid RSA body to the CT volume was 0.003 degrees. Points of interception with a plane calculated in the RSA orthogonal coordinate system were imported into the CT volume, facilitating the 3D visualization of the flexion axes. This study demonstrates a successful fusion of RSA and CT data, without significant loss of RSA accuracy. The method could be used for relating individual motion axes to a 3D representation of relevant joint anatomy, thus providing important information for clinical applications such as the development of joint prostheses.
  •  
4.
  •  
5.
  • Olivecrona, Henrik, et al. (författare)
  • A new technique for diagnosis of acetabular cup loosening using computed tomography - Preliminary experience in 10 patients
  • 2008
  • Ingår i: Acta Orthopaedica. - New York, NY, USA : Informa Healthcare. - 1745-3674 .- 1745-3682. ; 79:3, s. 346-353
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose: Considerable migration of the acetabular cup is required for diagnosis of loosening by conventional radiography. We have developed a new clinically applicable method for assessment of cup loosening using computed tomography (CT). Patients and methods 10 patients scheduled for revision hip replacement due to suspected wear or loosening were scanned twice with CT under torsion loading of the prosthesis. Two independent examiners assessed each patient with respect to motion of the acetabular cup relative to the pelvis using CT volume registration. The CT measurements were compared to findings at revision surgery. Results The method was applicable in 8 of the 10 patients. 1 patient had a severe tremor. In 1 patient, surgery revealed that the hip was ankylotic due to massive ectopic bone formation. This left 8 patients that could be evaluated. 4 cups were loose at surgery, and 3 of these cups could be seen to be mobile by CT. 4 cups that were stable on revision were accurately diagnosed as not being mobile by CT. Movements of less than 1 millimeter between bone and prosthesis could not be distinguished from errors in CT acquisition and volume registration. There was good agreement between the two observers. Interpretation Movement of loose acetabular cups during torsion loading could be detected using CT volume registration. It was sensitive to cup movement in 3 out of 4 cases of loose cups. The method was specific and yielded no false positive results.
  •  
6.
  • Olivecrona, Henrik, et al. (författare)
  • Spatial component position in total hip arthroplasty - Accuracy and repeatability with a new CT method
  • 2003
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 44:1, s. 84-91
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: 3D detection of centerpoints of prosthetic cup and head after total hip arthroplasty (THA) using CT. Material and Methods: Two CT examinations, 10 min apart, were obtained from each of 10 patients after THA. Two independent examiners placed landmarks in images of the prosthetic cup and head. All landmarking was repeated after 1 week. Centerpoints were calculated and compared. Results: Within volumes, all measurements of centerpoints of cup and head fell, with a 95% confidence, within one CT-voxel of any other measurement of the same object. Across two volumes, the mean error of distance between center of cup and prosthetic head was 1.4 mm (SD 0.73). Intra- and interobserver 95% accuracy limit was below 2 mm within and below 3 mm across volumes. No difference between intra- and interobserver measurements occurred. A formula for converting finite sets of point landmarks in the radiolucent tread of the cup to a centerpoint was stable. The percent difference of the landmark distances from a calculated spherical surface was within one CT-voxel. This data was normally distributed and not dependent on observer or trial. Conclusion: The true 3D position of the centers of cup and prosthetic head can be detected using CT. Spatial relationship between the components can be analyzed visually and numerically.
  •  
7.
  • Olivecrona, Henrik, et al. (författare)
  • Stability of acetabular axis after total hip arthroplasty, repeatability using CT and a semiautomated program for volume fusion
  • 2003
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 44:6, s. 653-661
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To validate a CT method for detecting changes in acetabular cup orientation after THA. Material and Methods: 26 CT examinations were obtained from a pelvic model with an uncemented acetabular cup. The model position was altered between acquisitions, but the cup axis angle vis-a-vis the pelvis was maintained. Data sets were combined into 37 pairs, each containing a unique positioning error. The pelvi in different examinations were fused, creating transformed volumes. Landmarks corresponding to the cup before and after fusion were placed interactively by two independent examiners. The orientation of the acetabular axis was calculated for each volume and compared across volumes. Results: Before fusion the mean angle error between the acetabular axes was 4.17degrees (SD +/- 1.95degrees). After fusion the mean angle error was 0.36degrees (SD +/- 0.17). The 95% repeatability limits were below 0.7degrees. There was no significant interobserver difference. Analysis of the cup landmarking pattern by condition numbers and individual landmark errors showed stability. Conclusion: Non-invasive fusion of CT volumes and a stable landmarking pattern for the acetabular cup outperforms routine plain radiography in detecting changes in the orientation of the acetabular axis over time. The method delivers both visual and numerical output and could be used in clinical practice.
  •  
8.
  • Olivecrona, Lotta, et al. (författare)
  • Acetabular component migration in total hip arthroplasty using CT and a semiautomated program for volume merging
  • 2002
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 43:5, s. 517-527
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To develop a non-invasive method for detection of acetabular cup migration after total hip arthroplasty (THA) with a higher degree of accuracy than routine plain radiography. Material and Methods: Two CT examinations, 10 min apart, were obtained from each of 10 patients that had undergone THA. Using an in-house developed semiautomated program for volume merging, the pelves in the two examinations were fused and the acetabular cup was visually and numerically evaluated to test the method's accuracy in detecting migration. Results: In the visual evaluation of the best match a 1-mm translation of the cup was detectable. The numerical evaluation, comparing landmarks placed in the images of the acetabular cup and the head of the femur component in the two examinations, showed the mean difference in orientation of acetabular axes to be 2.5degrees, the mean distance between centre of cup face to be 2.5 mm and the mean distance between centre of the head of the prosthetic femoral component to be 1 mm. Conclusion: This method has a significantly higher accuracy than routine plain radiography in detecting acetabular cup migration and could be used in clinical practice. It gives both a visual and a numerical correlate to migration.
  •  
9.
  • Olivecrona, Lotta, et al. (författare)
  • Assessing wear of the acetabular cup using computed tomography : an ex vivo study
  • 2005
  • Ingår i: Acta Radiologica. - London, UK : Informa Healthcare. - 0284-1851 .- 1600-0455. ; 46:8, s. 852-857
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To validate a clinically useful method for measuring acetabular cup wear using computed tomography (CT). Material and Methods: Eight uncemented acetabular cups were scanned twice ex vivo using CT. The linear penetration depth of the femoral component head into the cup and the thickness of the remaining polyethylene liner were measured in the CT volumes using dedicated software. Two independent examiners twice assessed each volume. The CT measurements were compared to direct measurements using a coordinate measuring device and micrometer measurements. Results: Accuracy of wear measurements expressed as penetration depth was +/- 0.6 and +/- 1.0 mm for the two examiners, respectively, with no significant differences between examiners, trials, and CT scans. Accuracy of measurements of remaining polyethylene was +/- 1.3 and +/- 1.0 mm, respectively, for the two examiners. Systematic differences between examiners were found, but no significant differences between trials and CT scans. These differences were due to different interpretations of metal artifacts in the volumes. Conclusion: The proposed CT method for evaluating wear as head penetration depth allows for reliable wear detection at a clinically relevant level. Measurements of remaining polyethylene on CT volumes are not as reliable as wear measurements owing to metal artifacts.
  •  
10.
  • Olivecrona, Lotta, et al. (författare)
  • Model studies on acetabular component migration in total hip arthroplasty using CT and a semiautomated program for volume merging
  • 2003
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 44:4, s. 419-429
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Validation of a non-invasive CT method for detection of acetabular cup migration after total hip arthroplasty in a phantom study. Material and Methods: 26 CT examinations were obtained of a pelvic model while altering the position of the acetabular cup. Using a previously described program for volume merging, the pelvi in different examinations were fused and the 3D alterations of the position of the acetabular cup were evaluated visually and numerically and correlated to direct measurements on the model. Results: Visually, two independent examiners differentiated between 0, 1 and 2 to 3 mm migration with 100% specificity and sensitivity. Numerically, the mean error over all cases between model and CT measurements was 0.04 mm (SD +/- 0.33). The mean absolute error between model and CT data was 0.26 mm (SD +/- 0.19). Intra- and interobserver 95% accuracy and repeatability limits were below 0.5/0.7 mm, respectively. No significant interobserver difference occurred. The data were normally distributed and not dependent on observer. Conclusion: The accuracy of this non-invasive method out-performs routine plain radiography. The method gives both visual and numerical correlates to migration and can be used in clinical practice.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 126
Typ av publikation
tidskriftsartikel (90)
konferensbidrag (29)
bok (4)
rapport (2)
bokkapitel (1)
Typ av innehåll
refereegranskat (115)
övrigt vetenskapligt/konstnärligt (11)
Författare/redaktör
Maguire Jr., Gerald ... (114)
Zeleznik, Michael P. (42)
Kramer, Elissa L. (35)
Schimpf, James H. (25)
Olivecrona, Henrik (22)
visa fler...
Horii, Steven C. (22)
Weidenhielm, Lars (15)
Sanger, Joseph J. (14)
Olivecrona, Lotta (11)
Baxter, Brent S. (8)
Megibow, Alec J. (8)
Crafoord, Joakim (8)
Maguire, Gerald Q. J ... (7)
Birnbaum, Bernard A. (6)
Chapnick, Jeffrey V (6)
Erdman, William A. (6)
Hitchner, Lewis E. (5)
Lundblad, Henrik (5)
Reddy, David P. (4)
Mahmoud, Faaiza (4)
Jacobsson, Hans (4)
Jonsson, Cathrine (4)
Dewyngaert, J. Keith (4)
Maguire Jr., Gerald ... (4)
Moy, Linda (4)
Sundin, Anders (3)
Aitken, Candice L. (3)
Ton, Anthony (3)
Aspelin, Peter (3)
Jonson, T (3)
Weinreb, Jeffrey C. (3)
Oratz, R. (3)
Martino, J. (3)
Stahl, T. J. (3)
Stark, Andreas (3)
Farrell, Edward J. (3)
Gorniak, Richard J. (3)
Svedmark, Per (3)
Brahme, Anders (2)
Lind, Bengt K (2)
McGuinness, Georgean ... (2)
Farde, Lars (2)
Anderlind, Eva (2)
Sallnäs Pysander, Ev ... (2)
Brodén, Cyrus (2)
Karlsson-Thur, Charl ... (2)
Tokarz, R. J. (2)
Millan, Evelyn (2)
Lee, Benjamin Y. (2)
visa färre...
Lärosäte
Kungliga Tekniska Högskolan (126)
Karolinska Institutet (26)
Uppsala universitet (4)
Stockholms universitet (4)
Göteborgs universitet (1)
Språk
Engelska (126)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (126)
Naturvetenskap (19)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy