SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "AMNE:(MEDICIN OCH HÄLSOVETENSKAP Medicinsk bioteknologi Annan medicinsk bioteknologi) ;lar1:(ri)"

Sökning: AMNE:(MEDICIN OCH HÄLSOVETENSKAP Medicinsk bioteknologi Annan medicinsk bioteknologi) > RISE

  • Resultat 1-10 av 11
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Fu, Ying, 1964-, et al. (författare)
  • Endocytic pathway of vascular cell adhesion molecule 1 in human umbilical vein endothelial cell identified in vitro by using functionalized nontoxic fluorescent quantum dots
  • 2019
  • Ingår i: Sensors and actuators. B, Chemical. - : Elsevier B.V.. - 0925-4005 .- 1873-3077. ; 297
  • Tidskriftsartikel (refereegranskat)abstract
    • Studies about vascular cell adhesion molecule 1 (VCAM1) in tumor growth, metastasis, and angiogenesis suggest that targeting VCAM1 expression is an attractive strategy for diagnosis and anti-tumor therapy. However, the endocytic pathway of VCAM1 in vascular cells has not been well characterized. In this study we visualize the endocytic pathway of tumor necrosis factor α (TNFα) induced VCAM1 in human umbilical vein endothelial cell (HUVEC) in vitro using 5-carboxyfluorescein labeled VCAM1 binding peptides and fluorescent water-dispersible 3-mercaptopropionic acid (3MPA)-coated CdSe-CdS/Cd0.5Zn0.5S/ZnS core–multishell nontoxic quantum dots (3MPA-QDs) functionalized with VCAM1 binding peptides. Clear key in vitro observations are as follows: (a) 3MPA-QDs functionalized with VCAM1 binding peptides, denoted as VQDs, adhered and aggregated cumulatively to cell membrane around 2 h after VQD deposition to cell culture medium and were found in lysosomes in TNFα-treated HUVECs approximately 24 h after VQD deposition; (b) VQDs remained in TNFα-treated HUVECs for the whole 16 days of the experimental observation period; (c) quite differently, 3MPA-QDs were endocytosed then exocytosed by HUVECs via endosomes in about 24–48 h after 3MPA-QD deposition. Our study suggests that VCAM1 molecules, initially expressed on cell membrane induced by TNFα treatment, are internalized into lysosomes. This provides a novel means to deliver materials to lysosomes such as enzyme replacement therapy. Moreover, our meticulous sensing methodology of devising fluorescent nontoxic QDs advances biosensing technique for studying cellular activities in vitro and in vivo. © 2019 The Authors
  •  
2.
  • Jonsson, Amanda, et al. (författare)
  • Therapy using implanted organic bioelectronics
  • 2015
  • Ingår i: Science Advances. - : American Association for the Advancement of Science. - 2375-2548. ; 1:4
  • Tidskriftsartikel (refereegranskat)abstract
    • Many drugs provide their therapeutic action only at specific sites in the body, but are administered in ways that cause the drug’s spread throughout the organism. This can lead to serious side effects. Local delivery from an implanted device may avoid these issues, especially if the delivery rate can be tuned according to the need of the patient. We turned to electronically and ionically conducting polymers to design a device that could be implanted and used for local electrically controlled delivery of therapeutics. The conducting polymers in our device allow electronic pulses to be transduced into biological signals, in the form of ionic and molecular fluxes, which provide a way of interfacing biology with electronics. Devices based on conducting polymers and polyelectrolytes have been demonstrated in controlled substance delivery to neural tissue, biosensing, and neural recording and stimulation. While providing proof of principle of bioelectronic integration, such demonstrations have been performed in vitro or in anesthetized animals. Here, we demonstrate the efficacy of an implantable organic electronic delivery device for the treatment of neuropathic pain in an animal model. Devices were implanted onto the spinal cord of rats, and 2 days after implantation, local delivery of the inhibitory neurotransmitter g-aminobutyric acid (GABA) was initiated. Highly localized delivery resulted in a significant decrease in pain response with low dosage and no observable side effects. This demonstration of organic bioelectronics-based therapy in awake animals illustrates a viable alternative to existing pain treatments, paving the way for future implantable bioelectronic therapeutics. 2015 © The Authors.
  •  
3.
  • Joffre, Thomas, 1987-, et al. (författare)
  • Characterization of interfacial stress transfer ability in acetylation-treated wood fibre composites using X-ray microtomography
  • 2017
  • Ingår i: Industrial crops and products (Print). - : Elsevier BV. - 0926-6690 .- 1872-633X. ; 95, s. 43-49
  • Tidskriftsartikel (refereegranskat)abstract
    • The properties of the fibre/matrix interface contribute to stiffness, strength and fracture behaviour of fibre-reinforced composites. In cellulosic composites, the limited affinity between the hydrophilic fibres and the hydrophobic thermoplastic matrix remains a challenge, and the reinforcing capability of the fibres is hence not fully utilized. A direct characterisation of the stress transfer ability through pull-out tests on single fibres is extremely cumbersome due to the small dimension of the wood fibres. Here a novel approach is proposed: the length distribution of the fibres sticking out of the matrix at the fracture surface is approximated using X-ray microtomography and is used as an estimate of the adhesion between the fibres and the matrix. When a crack grows in the material, the fibres will either break or be pulled-out of the matrix depending on their adhesion to the matrix: good adhesion between the fibres and the matrix should result in more fibre breakage and less pull-out of the fibres than poor adhesion. The effect of acetylation on the adhesion between the wood fibres and the PLA matrix was evaluated at different moisture contents using the proposed method. By using an acetylation treatment of the fibres it was possible to improve the strength of the composite samples soaked in the water by more than 30%.
  •  
4.
  • An, Junxue, et al. (författare)
  • Comparison of a Brush-with-Anchor and a Train-of-Brushes Mucin on Poly(methyl methacrylate) Surfaces : Adsorption, Surface Forces, and Friction
  • 2014
  • Ingår i: Biomacromolecules. - : American Chemical Society (ACS). - 1525-7797 .- 1526-4602. ; 15:4, s. 1515-1525
  • Tidskriftsartikel (refereegranskat)abstract
    • Interfacial properties of two types of mucins have been investigated at the aqueous solution/poly(methyl methacrylate) (PMMA) interface. One is commercially available bovine submaxillary mucin, BSM, which consists of alternating glycosylated and nonglycosylated regions. The other one is a recombinant mucin-type fusion protein, PSGL-1/mIgG(2b), consisting of a glycosylated mucin part fused to the Fc part of an immunoglobulin. PSGL-1/mIgG(2b) is mainly expressed as a (timer upon production. A quartz crystal microbalance with dissipation was used to study the adsorption of the mucins to PMMA surfaces. The mass of the adsorbed mucin layers, including the adsorbed mucin and water trapped in the layer, was found to be significantly higher for PSGL-1/mIgG(2b) than for BSM. Atomic force microscopy with colloidal probe was employed to study interactions and frictional forces between mucin-coated PMMA surfaces. Purely repulsive forces of steric origin were Observed between PSGL-1/mIgG(2b) mucin layers, whereas a small adhesion was detected between BSM layers and attributed to bridging. Both mucin layers reduced the friction force between PMMA surfaces in aqueous solution. The reduction was, however, significantly more pronounced for PSGL-1/mIgG(2b). The effective friction coefficient between PSGL-1/mIgG(2b)-coated PMMA surfaces is as low as 0.02 at low loads, increasing to 0.24 at the highest load explored, 50 nN. In contrast, a friction coefficient of around 0.7 was obtained between BSM-coated PMMA surfaces. The large differences in interfacial properties for the two mucins are discussed in relation to their structural differences.
  •  
5.
  • Sepehri, Sobhan, 1986, et al. (författare)
  • Homogeneous Differential Magnetic Assay
  • 2019
  • Ingår i: Acs Sensors. - : American Chemical Society (ACS). - 2379-3694. ; 4:9, s. 2381-2388
  • Tidskriftsartikel (refereegranskat)abstract
    • Assays are widely used for detection of various targets, including pathogens, drugs, and toxins. Homogeneous assays are promising for the realization of point-of-care diagnostics as they do not require separation, immobilization, or washing steps. For low concentrations of target molecules, the speed and sensitivity of homogeneous assays have hitherto been limited by slow binding kinetics, time-consuming amplification steps, and the presence of a high background signal. Here, we present a homogeneous differential magnetic assay that utilizes a differential magnetic readout that eliminates previous limitations of homogeneous assays. The assay uses a gradiometer sensor configuration combined with precise microfluidic sample handling. This enables simultaneous differential measurement sample containing a synthesized Vibrio cholerae target and a negative control sample, which reduces the background signal and increases the readout speed. Very low concentrations of targets down to femtomolar levels are thus detectable without any additional amplification of the number of targets. Our homogeneous differential magnetic assay method opens new possibilities for rapid and highly sensitive diagnostics at the point of care.
  •  
6.
  • Chow, Joyce A, et al. (författare)
  • A design study investigating augmented reality and photograph annotation in a digitalized grossing workstation
  • 2017
  • Ingår i: Journal of Pathology Informatics. - : Medknow Publications. - 2229-5089 .- 2153-3539. ; 8
  • Tidskriftsartikel (refereegranskat)abstract
    • Context: Within digital pathology, digitalization of the grossing procedure has been relatively underexplored in comparison to digitalization of pathology slides. Aims: Our investigation focuses on the interaction design of an augmented reality gross pathology workstation and refining the interface so that information and visualizations are easily recorded and displayed in a thoughtful view. Settings and Design: The work in this project occurred in two phases: the first phase focused on implementation of an augmented reality grossing workstation prototype while the second phase focused on the implementation of an incremental prototype in parallel with a deeper design study. Subjects and Methods: Our research institute focused on an experimental and “designerly” approach to create a digital gross pathology prototype as opposed to focusing on developing a system for immediate clinical deployment. Statistical Analysis Used: Evaluation has not been limited to user tests and interviews, but rather key insights were uncovered through design methods such as “rapid ethnography” and “conversation with materials”. Results: We developed an augmented reality enhanced digital grossing station prototype to assist pathology technicians in capturing data during examination. The prototype uses a magnetically tracked scalpel to annotate planned cuts and dimensions onto photographs taken of the work surface. This article focuses on the use of qualitative design methods to evaluate and refine the prototype. Our aims were to build on the strengths of the prototype's technology, improve the ergonomics of the digital/physical workstation by considering numerous alternative design directions, and to consider the effects of digitalization on personnel and the pathology diagnostics information flow from a wider perspective. A proposed interface design allows the pathology technician to place images in relation to its orientation, annotate directly on the image, and create linked information. Conclusions: The augmented reality magnetically tracked scalpel reduces tool switching though limitations in today's augmented reality technology fall short of creating an ideal immersive workflow by requiring the use of a monitor. While this technology catches up, we recommend focusing efforts on enabling the easy creation of layered, complex reports, linking, and viewing information across systems. Reflecting upon our results, we argue for digitalization to focus not only on how to record increasing amounts of data but also how these data can be accessed in a more thoughtful way that draws upon the expertise and creativity of pathology professionals using the systems.
  •  
7.
  • He, Hans, et al. (författare)
  • Accurate graphene quantum Hall arrays for the new International System of Units
  • 2022
  • Ingår i: Nature Communications. - : Nature Research. - 2041-1723. ; 13:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Graphene quantum Hall effect (QHE) resistance standards have the potential to provide superior realizations of three key units in the new International System of Units (SI): the ohm, the ampere, and the kilogram (Kibble Balance). However, these prospects require different resistance values than practically achievable in single graphene devices (~12.9 kΩ), and they need bias currents two orders of magnitude higher than typical breakdown currents IC ~ 100 μA. Here we present experiments on quantization accuracy of a 236-element quantum Hall array (QHA), demonstrating RK/236 ≈ 109 Ω with 0.2 part-per-billion (nΩ/Ω) accuracy with IC ≥ 5 mA (~1 nΩ/Ω accuracy for IC = 8.5 mA), using epitaxial graphene on silicon carbide (epigraphene). The array accuracy, comparable to the most precise universality tests of QHE, together with the scalability and reliability of this approach, pave the road for wider use of graphene in the new SI and beyond. © 2022, The Author(s).
  •  
8.
  • Kjellin, Per, et al. (författare)
  • Biomechanical and histomorphometric evaluation of skin integration on titanium and PEEK implants with different surface treatments
  • 2022
  • Ingår i: Journal of materials science. Materials in medicine. - : Springer. - 0957-4530 .- 1573-4838. ; 33:10
  • Tidskriftsartikel (refereegranskat)abstract
    • Percutaneous implants are frequently affected by bacterial growth at the skin-implant interface. Integration between implant and surrounding skin is important to prevent bacteria from spreading to the underlying tissue. The standard method to evaluate skin-implant integration is by histomorphometry on samples which have been placed in tissue grown in vivo or ex vivo. In this study, a biomechanical method was developed and evaluated. The integration of implants into porcine skin was studied in an ex vivo model, where pig skin samples were cultivated in a nutrient solution. Cylindrical shaped implants, consisting of polyether ether ketone (PEEK) and titanium (Ti) with different surface treatments, were implanted in the skin tissue and the skin was grown in nutrient solution for 2 weeks. The implants were then extracted from the implantation site and the mechanical force during extraction was measured as a quantitative assessment of skin-implant integration. Implants from each group were also processed for histomorphometry and the degree of epidermal downgrowth (ED) and tissue to implant contact (TIC) was measured. A higher mean pullout force was observed for the PEEK implants compared to the Ti implants. Applying nanosized hydroxyapatite (HA) on Ti and PEEK increased the pullout force compared to uncoated controls, 24% for machined and 70% for blasted Ti, and 51% for machined PEEK. Treatment of Ti and PEEK with nanosized zirconium phosphate (ZrP) did not increase the pullout force. The histomorphometry analysis showed correlation between ED and pullout force, where the pullout force was inversely proportional to ED. For TIC, no significant differences were observed between the groups of same material (i.e. Ti, Ti+HA, Ti+ZrP, and PEEK, PEEK + HA, PEEK + ZrP), but it was significantly higher for PEEK compared to Ti. Scanning electron microscopy analysis was done on samples before and after the pullout tests, showing that the ZrP coating was unaffected by the 2 week ex vivo implantation and pullout procedure, no dissolution or detachment of the coating was observed. For the HA coating, a loss of coating was seen on approximately 5% of the total surface area of the implant. [Figure not available: see fulltext.] © 2022, The Author(s).
  •  
9.
  • Skedung, Lisa, et al. (författare)
  • Feeling small : Exploring the Tactile Perception Limits
  • 2013
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 3, s. 2617-
  • Tidskriftsartikel (refereegranskat)abstract
    • The human finger is exquisitely sensitive in perceiving different materials, but the question remains as to what length scales are capable of being distinguished in active touch. We combine material science with psychophysics to manufacture and haptically explore a series of topographically patterned surfaces of controlled wavelength, but identical chemistry. Strain-induced surface wrinkling and subsequent templating produced 16 surfaces with wrinkle wavelengths ranging from 300 nm to 90 mu m and amplitudes between 7 nm and 4.5 mu m. Perceived similarities of these surfaces (and two blanks) were pairwise scaled by participants, and interdistances among all stimuli were determined by individual differences scaling (INDSCAL). The tactile space thus generated and its two perceptual dimensions were directly linked to surface physical properties - the finger friction coefficient and the wrinkle wavelength. Finally, the lowest amplitude of the wrinkles so distinguished was approximately 10 nm, demonstrating that human tactile discrimination extends to the nanoscale.
  •  
10.
  • Shah, Furqan A., et al. (författare)
  • Long-term osseointegration of 3D printed CoCr constructs with an interconnected open-pore architecture prepared by electron beam melting.
  • 2016
  • Ingår i: Acta Biomaterialia. - : Elsevier BV. - 1878-7568 .- 1742-7061. ; 36:May, s. 296-309
  • Tidskriftsartikel (refereegranskat)abstract
    • In orthopaedic surgery, cobalt chromium (CoCr) based alloys are used extensively for their high strength and wear properties, but with concerns over stress shielding and bone resorption due to the high stiffness of CoCr. The structural stiffness, principally related to the bulk and the elastic modulus of the material, may be lowered by appropriate design modifications, to reduce the stiffness mismatch between metal/alloy implants and the adjacent bone. Here, 3D printed CoCr and Ti6Al4V implants of similar macro-geometry and interconnected open-pore architecture prepared by electron beam melting (EBM) were evaluated following 26week implantation in adult sheep femora. Despite higher total bone-implant contact for Ti6Al4V (39±4%) than CoCr (27±4%), bone formation patterns were similar, e.g., densification around the implant, and gradual ingrowth into the porous network, with more bone in the outer half (periphery) than the inner half (centre). Raman spectroscopy revealed no major differences in mineral crystallinity, the apatite-to-collagen ratio, or the carbonate-to-phosphate ratio. Energy dispersive X-ray spectroscopy showed similar Ca/P ratio of the interfacial tissue adjacent to both materials. Osteocytes made direct contact with CoCr and Ti6Al4V. While osteocyte density and distribution in the new-formed bone were largely similar for the two alloys, higher osteocyte density was observed at the periphery of the porous network for CoCr, attributable to slower remodelling and a different biomechanical environment. The results demonstrate the possibility to achieve bone ingrowth into open-pore CoCr constructs, and attest to the potential for fabricating customised osseointegrated CoCr implants for load-bearing applications.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 11
Typ av publikation
tidskriftsartikel (11)
Typ av innehåll
refereegranskat (11)
Författare/redaktör
Albert, J. (1)
Kurti, Arianit, 1977 ... (1)
Nilsson, Mats (1)
Berggren, Magnus (1)
Nilsson, David (1)
Holgersson, Jan (1)
visa fler...
Claesson, Per M. (1)
Brismar, Hjalmar (1)
Larsson, Anette, 196 ... (1)
Wang, Qin (1)
Omar, Omar (1)
Lara Avila, Samuel, ... (1)
Song, Z. (1)
Kubatkin, Sergey, 19 ... (1)
Thomsen, Peter, 1953 (1)
Strømme, Maria, 1970 ... (1)
Andersson, Therese (1)
Matic, Aleksandar, 1 ... (1)
Jesorka, Aldo, 1967 (1)
Nilsson, Anki (1)
Bergsten, Tobias (1)
Stading, Mats, 1962 (1)
Zardán Gómez de la T ... (1)
Blomgren, Jakob (1)
Sepehri, Sobhan, 198 ... (1)
Kalaboukhov, Alexei, ... (1)
Winkler, Dag, 1957 (1)
Schneiderman, Justin ... (1)
Persson, Cecilia (1)
Palmquist, Anders, 1 ... (1)
Skedung, Lisa (1)
Lausmaa, Jukka (1)
Rutland, Mark (1)
An, Junxue (1)
Dédinaité, Andra (1)
Bardage, Stig (1)
Eklund, Gunnar (1)
Andersson, Helene, 1 ... (1)
Hjärtstam, Johan, 19 ... (1)
von Corswant, Christ ... (1)
Häbel, Henrike, 1987 (1)
Olsson, Anna, 1985 (1)
Sandhagen, Sofie (1)
Persson, Michael, 19 ... (1)
Suska, Felicia, 1974 (1)
Emanuelsson, Lena, 1 ... (1)
Håkansson, Joakim (1)
Snis, Anders (1)
Jonsson, Amanda (1)
Linderoth, B (1)
visa färre...
Lärosäte
Göteborgs universitet (6)
Kungliga Tekniska Högskolan (4)
Chalmers tekniska högskola (4)
Karolinska Institutet (4)
Uppsala universitet (2)
visa fler...
Stockholms universitet (2)
Linköpings universitet (2)
Linnéuniversitetet (1)
visa färre...
Språk
Engelska (11)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (11)
Naturvetenskap (7)
Teknik (6)
Lantbruksvetenskap (1)
Samhällsvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy