1.
  • Forsström, Anna (författare)
  • Ground freezing with the use of thermosyphons : field tests from an installation at Dundret, Sweden
  • 2002
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • Thermopiles and thermosyphons are sometimes used in permafrost areas in preventing permafrost thawing and, in some cases, to reduce frost heaving. The system is used to maintain permafrost as well as to stabilise weak unfrozen soils. Thermosyphons might also be used in a slightly different way, i.e. to create permafrost in non-permafrost areas, but at locations where relative severe winters occur. Ski resorts in Sweden and the rest of Scandinavia are interested in extending their ski seasons in the autumn and spring and therefore want to have a continuous snow cover as early as possible. For this reason a thermosyphon was installed at Dundret, Gällivare in November 2000. The aim was to investigate if thermosyphons could be used to make the ground cool enough to create permafrost, or so that initial snowfalls would not melt in early winter. If it is possible to create permafrost in areas without natural permafrost, this could be utilised to cool the ground. A substantial snow cover would then be easier to form earlier in the season. Early snowfall often melts from bottom and up, i.e. due to the non-frozen and warm ground. If the ground is cooled, melting is thus reduced. The area tested had a width of 3.75 m and a length of 20 m. Loggers measured the ground temperature continuously with 72 thermocouples, where 132 thermocouples were available for manual measurements. The temperature measurements at the artificially cooled area were compared with the temperature measurements at the undisturbed ground. In this report ground temperature measurements for November 2000 to May 2001 and November 2001 have been analysed. In general, the temperatures are lower within and closer to the installation than when compared to the undisturbed ground.
  •  
2.
  • Forsström, Anna (författare)
  • Ground thermal analysis of thermosyphon installations
  • 2002
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • Thermosyphons have been used to stabilise ground in permafrost areas since the 60's. On-grade foundations over ice rich permafrost require insulation below the floor to retard heat flow and a cooling system below the insulation to prevent thermal degradation of the underlying permafrost. Heat transfer in the ground and at thermosyphon installations are explained and discussed in this report. Further, methods for designing thermosyphon installations at buildings and roadways are described. Illustrated, as examples, are the case with a varying surface temperature, a roadway and a cross-country ski track.
  •  
3.
  • Forsström, Anna, et al. (författare)
  • Thermosyphon cooling of Chena Hot Springs Road
  • 2002
  • Ingår i: Cold Regions Engineering Cold Regions Impacts on Transportation and Infrastructure.. - New York : American Society of Civil Engineers (ASCE). - 784406219 ; , s. 645-655
  • Konferensbidrag (refereegranskat)abstract
    • Thermosyphons have been used to maintain permafrost below structures for over forty years. The Chena Hot Springs Road Test Section became operational during the fall of 1998 and includes three test sections underlain with different types of thermosyphons plus a control section. The test section overlays high-moisture-content permafrost. After two seasons, the thaw depth decreased and the freezing depth increased in all sections, including the control. Pavement edge temperatures showed a decided cooling trend which was slight for the control, more pronounced for the UAF/CRREL units and AFI flat loop evaporator units, and highest for the AFI buried units section. The centerline thermal conditions relate to the condenser size, while the pavement edge or shoulder conditions relate to the type of installation. During the winter season, the AFI buried condenser thermosyphons show surface warming and sublimation of snow closer to that of the control section, while the other two test sections are colder at the surface during the winter season.
  •  
4.
  • Forsström, Anna (författare)
  • Use of thermosyphons in a subarctic climate
  • 2002
  • Licentiatavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • In frozen ground, climatic changes and thermal disturbance might cause thawing and degradation of ground previously frozen. Foundations built on frozen ground might be destroyed in a matter of a few seasons. These problems are mostly pronounced in permafrost regions, but also exist in regions with more moderate climates. If thawing takes place the strength of the ground may be greatly reduced. Settlement and stability problems may therefore arise. Insulation, ventilation, or refrigeration systems are used to maintain permafrost locally around foundations. Another possible method to achieve this objective is the use of two-phase thermosyphons. By using this technique heat is transferred from the ground into the air at a higher rate than what would be the case for natural freezing only. A frozen area created in the ground will then increase in size year after year. Ski resorts in Sweden are interested in extending their ski seasons, thereby resulting in a considerable profit for them. In the autumn, the interest is mostly pronounced for cross-country skiing areas. If the ground beneath the ski track could be frozen earlier in the season, the first cover of natural or man-made snow would not easily melt away. In the spring, snow melts earlier in the ski-lift area compared to the ski slopes. If the ground could be kept frozen longer by artificial means and solar radiation is prevented, then the snow would not thaw easily and the ski-lifts could be kept open longer. The aim of this project was two-fold: to examine how well thermosyphons work in Scandinavia and other parts of the world with similar subarctic climates, and to get an insight into the design methods for thermosyphons and their installations. Installations of thermosyphons were done in the autumn of 2000 at two sites in northern Sweden. One thermosyphon was installed in Dundret, Gällivare, which is a ski resort at approximately N67° where the ground temperature as well as the climatic data has been studied. Air and ground temperatures were measured at the second installation at the university campus in Luleå, approximately N66°. This licentiate thesis consists of three parts. A technical report entitled "Ground Freezing with the use of Thermosyphons, Field Tests from an Installation at Dundret, Sweden" is devoted as "Part A", published at Luleå University of Technology, May 2002. In this report the thermosyphon installation in Dundret, Gällivare, Sweden is described. Further, ground temperature measurements for November 2000 to May 2001 and November 2001 have been analysed. In general, temperatures are lower within and closer to the installation than those in the undisturbed ground. A ground temperature difference of -6°C inside the installation area compared to the undisturbed area was observed at certain places throughout the year 2000/2001. The significant artificial cooling was noted at the beginning of February 2001. The conclusions of the study were that thermosyphons work in the climate of northern Sweden. Moreover, "Part B" is a conference paper entitled "Cooling of the Chena Hot Springs Road with thermosyphons", which was submitted and accepted to the 11th International Conference on Cold Regions Engineering in Anchorage, Alaska, May 2002. The Chena Hot Springs Road test section became operational during the autumn of 1998 and includes three test sections underlain with different types of thermosyphons plus a control section. The paper includes a description of the test site and analysis of the ground temperature measurements. It was concluded that thermosyphons could be used to cool the sub-base of the road in order to stabilise the constructions in permafrost areas. The most effective thermosyphon for the middle of the roadway was the AFI Flat unit, and the AFI Buried unit for the edge of the pavement. Lastly, a research report entitled "Ground Thermal Analysis of Thermosyphon Installations", published at Luleå University of Technology, May 2002, is devoted as "Part C" in the thesis. Heat transfer in the ground and at thermosyphon installations are explained in this report. Further, methods for dimensioning thermosyphon installations at buildings and roadways are described. A roadway and a cross-country ski track are both exemplified. In conclusion further work should be performed on developing a thermal analysis program for thermosyphon installations at roadways.
  •  
5.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5
Typ av publikation
rapport (2)
konferensbidrag (1)
tidskriftsartikel (1)
licentiatavhandling (1)
Typ av innehåll
övrigt vetenskapligt/konstnärligt (3)
populärvet., debatt m.m. (1)
refereegranskat (1)
Författare/redaktör
Forsström, Anna (5)
Knutsson, Sven (2)
Long, Erwin L. (1)
Zarling, John P. (1)
Lärosäte
Luleå tekniska universitet (5)
Språk
Engelska (4)
Svenska (1)
Forskningsämne (UKÄ/SCB)
Teknik (5)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy