SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L4X0:0345 0082 ;srt2:(1975-1979);spr:eng"

Sökning: L4X0:0345 0082 > (1975-1979) > Engelska

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ask, Per, 1950- (författare)
  • Oesophageal manometry : design and evaluation of measurement systems
  • 1978
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • The aim of this study was to investigate the technical characteristics of oesophageal manometry systems and to improve the performance of these systems.The investigation of the characteristics of oesophageal manometry systems with non-perfused catheters or catheters perfused with a flow generated by a syringe pump did not show properties which fullfilled the requirements for accurate pressure measurements. The bandwidth of the pressure mesurement system was limited by the high compliance of the syringe perfusion pump. The characteristics of perfused systems were improved by the design of a low-compliance perfusion pump. The frequency characteristics of a pressure measurement system utilizing the low-compliance perfusion pump seemed to be determined by the properties of the cathetermanometer system. The frequency content of oesophageal peristaltic pressure was studied by use of a measurement system including the low-compliance perfusion pump. This investigation showed that a bandwidth of about 8 Hz or more is necessary for accurate measurements, which bandwidth can only be obtained with a low-compliance system. In a clinical study a non-perfused system and a system perfused with a syringe pump were compared simultaneously to a system with the low-compliance perfusion pump. The non-perfused system and the system perfused with the syringe pump gave lower peristaltic and sphincter pressure amplitudes than the system with the low-compliance perfusion pump. Since the oesophageal sphincter pressure varies in different radial directions, a pressure transducer has been devised, the mechanical design of which gives an integration of a radial pressure profile. The transducer has a linear static and dynamic transfer function.
  •  
2.
  •  
3.
  • Nilsson, Gert, 1947- (författare)
  • On the measurement of evaporative water loss : methods and clinical applications
  • 1977
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • The new method for measurement of water loss by evaporation from the skin described in paper I, offers a high degree of accuracy and improved sensitivity in comparison with devices reported previously. Rapid recordings can be made by technically untrained persons both in clinical departments and in the laboratory.Using this method, the average insensible perspiration from the skin of healthy adult subjects at rest was found to be 381, 526 and 695 gr per day at ambient temperatures of 22°, 27° and 30°C, respectively. On the head, hands and feet the evaporation rate was high, while on other body surface areas more moderate values were recorded,In a clinical study on newborn infants, a linear relationship between the evaporative water loss from the skin and the ambient humidity was found. At an ambient temperature of 34.5°c and an ambient relative humidity of 50% the average transepidermal water loss was calculated to be 8.1 g/m2h.In burned patients high evaporation rates from about 140 g/m2h to over 220 g/m2h were recorded on the injured skin surfaces. Biological dressings were only slightly permeable to water vapour, while the permeability of the artificial dressings tested was generally high.By recording the rate of increase in vapour concentration in a closed measurement chamber placed over the exposed abdominal cavity during surgery, the water loss by evaporation from wounds and exteriorized viscera was determined. At incisions of minor extent the evaporative water loss was low, while at larger incisions with exteriorized viscera the water loss by evaporation from the wound exceeded the basal cutaneous perspiration of healthy adult subjects.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3
Typ av publikation
doktorsavhandling (3)
Typ av innehåll
övrigt vetenskapligt/konstnärligt (3)
Författare/redaktör
Ask, Per, 1950- (1)
Nilsson, Gert, 1947- (1)
Magnusson, Karl-Eric ... (1)
Lärosäte
Linköpings universitet (3)
Språk
Forskningsämne (UKÄ/SCB)
Naturvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy