SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0001 5385 OR L773:1784 973X ;pers:(Budts Werner)"

Sökning: L773:0001 5385 OR L773:1784 973X > Budts Werner

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Stassen, Jan, et al. (författare)
  • Covered stent placement for treatment of coarctation of the aorta: immediate and long-term results.
  • 2021
  • Ingår i: Acta cardiologica. - : Informa UK Limited. - 1784-973X .- 0001-5385 .- 0373-7934. ; 76:5, s. 464-472
  • Tidskriftsartikel (refereegranskat)abstract
    • This study aimed to describe the safety and efficacy of covered stents in patients with coarctation of aorta (CoA) for immediate and long-term follow-up.Covered stents are increasingly being used in (re)CoA, mainly to reduce the risk of aortic wall injuries (AWI). However, limited data are available on intermediate and long-term outcome.In 89 patients (67.4% male) with a mean age of 23.9 ± 15.8 (min max range 5.1-71.6) years were 102 covered stents implanted (January 2003 - December 2017). Short-term pre/post-implant hemodynamics and angiographic data were reported. Changes in blood pressure, the use of antihypertensive drugs and complications were recorded during follow-up.The procedural success rate was 100%. The mean invasive ascending-to-descending aorta systolic gradient under general anaesthesia decreased from 25 ± 16 mmHg to 4 ± 7 mmHg (p < 0.001). After a mean follow-up time of 6.6 ± 3.7 years, there was a persistent improvement of the mean systolic blood pressure gradient between right arm and leg (-7 ± 18 vs 38 ± 24 mmHg; p < 0.001). A larger proportion of patients required antihypertensive medication (33.7% vs 50.0%, p = 0.017) and needed ≥ 2 drugs (20.2% vs 27.4%, p = 0.066) to control blood pressure. Long-term adverse events were found in 4.5% of patients [covered stent fracture (n = 3), aneurysm formation (n = 2)].Covered stent implantation for CoA is highly successful, safe and results in a persistent hemodynamic improvement in the immediate and long-term outcome. Lifelong follow-up with additional antihypertensive drug treatment is mandatory to maintain favourable hemodynamic results after stenting.Long-term follow-up data on covered stents in patients with coarctation of the aorta are scarce. A cohort of 89 patients was reviewed. The procedural implantation success rate was 100%. The invasive gradient decreased from 25 ± 16 mmHg to 4 ± 7 mmHg (p < 0.001). After follow-up of 6.6 ± 3.7 years, there was a persistent improvement of the clinical systolic blood pressure gradient (-7 ± 18 vs 38 ± 24 mmHg; p < 0.001). However, a larger proportion of patients required antihypertensive medication (33.7% vs 50.0%, p = 0.017). Covered stent implantation results in favourable hemodynamic effects, but lifelong follow-up with additional antihypertensive drug treatment is mandatory to maintain these results.
  •  
2.
  • Erard, Margot, et al. (författare)
  • Left atrial strain in patients after arterial switch operation for transposition of the great arteries
  • 2023
  • Ingår i: Acta Cardiologica. - 0001-5385 .- 0373-7934.
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Left atrial (LA) strain, comprising LA reservoir, conduit and contractile function could add mechanistic information of patients after arterial switch operation (ASO) for transposition of the great arteries (TGA). ASO patients might have abnormal ventriculoarterial coupling, which makes them vulnerable to left ventricle (LV) dysfunction and results in reduced exercise capacity. This explorative study aimed to evaluate the relation between LA strain, atrial size, ventricular function, and exercise data obtained by cardiopulmonary exercise testing (CPET). Methods: In a cohort of 44 patients (71% male, mean age 25 ± 4 years) LA strain was measured using transthoracic speckle-tracking echocardiography. Further assessment involved standard echocardiography, CPET evaluation, and blood sampling. LA strain values were compared to normal values. Correlations were calculated. Regression analysis with all strain variables to the CPET data was performed. Results: LA reservoir, conduit and contractile strain were normal in 30%, 89% and 50% of the patients, respectively. LA reservoir/contractile strain correlated to LV ejection fraction (ρ 0.310/−0.159, respectively) and LA reservoir/conduit strain correlated to the LA volume index (ρ 0.336/−0.357, respectively). None of the individual LA strain parameters were associated with the CPET variables. In multivariate regression analysis, LA contractile strain was significantly associated with the percentage of predicted maximal heart rate (β − 2.555). Conclusions: These data suggest that in TGA patients after ASO repair LA strain is impaired and correlates with LA size and LV function. However, impaired LA strain wasn’t associated with the standard CPET parameters. As such, clinical significance needs to be further unravelled.
  •  
3.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy