SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0034 6748 OR L773:1089 7623 ;pers:(Vogt Ulrich)"

Sökning: L773:0034 6748 OR L773:1089 7623 > Vogt Ulrich

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bertilsson, Michael, et al. (författare)
  • Laboratory arrangement for soft x-ray zone-plate efficiency measurements
  • 2007
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 78:2, s. 026103-
  • Tidskriftsartikel (refereegranskat)abstract
    • We demonstrate a laboratory-scale arrangement for rapid and accurate measurements of the absolute and local efficiency of soft x-ray micro zone plates in the water window. This in-house instrument is based on a single-line lambda=2.88 nm liquid-jet laser-plasma source. Measurements are performed by a simultaneous comparison of first diffraction-order photon flux with the flux in a calibrated reference signal. This arrangement eliminates existing source emission fluctuations. The performance of the method is demonstrated by the result from measurements of two similar to 55 mu m diameter nickel micro zone plates, showing a groove efficiency of 12.9%+/- 1.1% and 11.7%+/- 1.0%. Furthermore, we show that spatially resolved efficiency mapping is an effective tool for a detailed characterization of local zone plate properties. Thus, this laboratory-scale instrument allows rapid feedback to the fabrication process which is important for future improvements.
  •  
2.
  • Kördel, Mikael, et al. (författare)
  • Stability investigation of a cryo soft x-ray microscope by fiber interferometry
  • 2020
  • Ingår i: Review of Scientific Instruments. - : American Institute of Physics (AIP). - 0034-6748 .- 1089-7623. ; 91:2
  • Tidskriftsartikel (refereegranskat)abstract
    • We present a stability investigation of the Stockholm laboratory cryo soft x-ray microscope. The microscope operates at a wavelength of 2.48 nm and can image biological samples at liquid-nitrogen temperatures in order to mitigate radiation damage. We measured the stability of the two most critical components, sample holder and optics holder, in vacuo and at cryo temperatures at both short and long time scales with a fiber interferometer. Results revealed vibrations in the kHz range, originating mainly from a turbo pump, as well as long term drifts in connection with temperature fluctuations. With improvements in the microscope, earlier stability issues vanished and close-to diffraction-limited imaging could be achieved. Moreover, our investigation shows that fiber interferometers are a powerful tool in order to investigate position-sensitive setups at the nanometer level.
  •  
3.
  • Legall, H., et al. (författare)
  • Spatial and spectral characterization of a laser produced plasma source for extreme ultraviolet metrology
  • 2004
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 75:11, s. 4981-4988
  • Tidskriftsartikel (refereegranskat)abstract
    • We present a laser produced plasma (LPP) source optimized for metrology and the results of its radiometric characterization. The presented (LPP) source can be used for reflectometry and spectroscopy in the soft x-ray range. For these applications, stable operation with high spectral photon yields high reliability in continuous operation and, to reach high spectral resolution, a small source size and high source point stability is necessary. For the characterization of the source, special instruments have been designed and calibrated using the soft x-ray radiometry beamline of the Physikalisch-Technische-Bundesanstalt at BESSY. These instruments are an imaging spectrometer, a double multilayer tool for in-band power measurements, a transmission slit grating spectrograph, and a pinhole camera. From the measurements a source size of 30 mumx55 mum (2sigma, horizontal by vertical) and a stability of better than 5 mum horizontally and 9 mum vertically were obtained. The source provides a flat continuous emission in the extreme ultraviolet (EUV) range around 13.4 nm and a spectral photon flux of up to 1*10(14)/(s sr 0.1 nm) at a pump laser pulse energy of 650 mJ. The shot-to-shot stability of the source is about 5% (1sigma) for laser pulse energies above 200 mJ. It is shown that an Au-LPP source provides spectrally reproducible emission with sufficient power at low debris conditions for the operation of a laboratory based EUV reflectometer and for spectroscopy.
  •  
4.
  • Otendal, Mikael, et al. (författare)
  • A 9 keV electron-impact liquid-gallium-jet x-ray source
  • 2008
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 79:1, s. 016102-
  • Tidskriftsartikel (refereegranskat)abstract
    • We demonstrate a high-brightness compact 9 keV electron-impact microfocus x-ray source based on a liquid-gallium-jet anode. A similar to 30 W, 50 kV electron gun is focused onto the similar to 20 m/s, 30 mu m diameter liquid-gallium-jet anode to produce an similar to 10 mu m full width at half maximum x-ray spot. The peak spectral brightness is >2 x 10(10) photons/(s mm(2) mrad(2) x 0.1% BW). Calculation and experiments show potential for increasing this brightness by approximately three orders of magnitude, making the source suitable for laboratory-scale x-ray crystallography and hard x-ray microscopy.
  •  
5.
  • Stankevic, Tomas, et al. (författare)
  • Interferometric characterization of rotation stages for X-ray nanotomography
  • 2017
  • Ingår i: Review of Scientific Instruments. - : American Institute of Physics (AIP). - 0034-6748 .- 1089-7623. ; 88:5
  • Tidskriftsartikel (refereegranskat)abstract
    • The field of three-dimensional multi-modal X-ray nanoimaging relies not only on high-brilliance X-rays but also on high-precision mechanics and position metrology. Currently available state-of-the-art linear and rotary drives can provide 3D position accuracy within tens to hundreds of nm, which is often insufficient for high resolution imaging with nanofocused X-ray beams. Motion errors are especially troublesome in the case of rotation drives and their correction is more complicated and relies on the metrology grade reference objects. Here we present a method which allows the characterisation and correction of the radial and angular errors of the rotary drives without the need for a highly accurate metrology object. The method is based on multi-probe error separation using fiber-laser interferometry and uses a standard cylindrical sample holder as a reference. The obtained runout and shape measurements are then used to perform the position corrections using additional drives. We demonstrate the results of the characterization for a piezo-driven small rotation stage. The error separation allowed us to measure the axis runout to be approximately +/-1.25 mu m, and with active runout compensation this could be reduced down to +/-42 nm.
  •  
6.
  • Vogt, Ulrich, et al. (författare)
  • Design and application of a zone plate monochromator for laboratory soft x-ray sources
  • 2001
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 72:1, s. 53-57
  • Tidskriftsartikel (refereegranskat)abstract
    • In this article we describe the test of a zone plate monochromator for a laboratory soft x-ray source which is a laser produced plasma on a liquid jet target. The monochromator consists of a zone plate and a pinhole. Due to the special zone plate used (condensor zone plate KZP7) the monochromator is particularly suitable for laboratory sources since it collects a relatively large solid angle in the present setup. Depending upon the diameter of the pinhole a monochromaticity of up to lambda/Delta lambda =600 can be achieved. The usefulness of the linear monochromator was proven on the basis of a filter transmission measurement. The monochromator can be used for several applications. In particular it is suitable for time-resolved x-ray absorption spectroscopy and pump and probe experiments. The use for such investigations is discussed.
  •  
7.
  • Vogt, Ulrich, et al. (författare)
  • High resolution x-ray absorption spectroscopy using a laser plasma radiation source
  • 2004
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 75:11, s. 4606-4609
  • Tidskriftsartikel (refereegranskat)abstract
    • In this article we present a setup of a spectrometer for near edge x-ray absorption spectroscopy at the carbon K-edge (284 eV). The spectrometer works with a laser produced plasma as x-ray source and a single x-ray optical element in grazing incidence configuration called off-axis reflection zone plate. Using different sample foils we were able to demonstrate a spectral resolution of E/DeltaEapproximate to600. The positions of specific absorption peaks are in agreement with data measured at synchrotron sources. Since the off-axis zone plate is a focusing system, the x-ray flux in the detector plane is high enough to record an absorption spectrum on a charge-coupled device detector with a single shot. In the single shot modus a spectrum can be recorded before a sample degradation takes place. This will enable time-resolved experiments using pump-probe techniques.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy