SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0041 1132 ;lar1:(uu)"

Sökning: L773:0041 1132 > Uppsala universitet

  • Resultat 1-10 av 26
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Auvinen, Marja-Kaisa, et al. (författare)
  • Patterns of blood use in Sweden from 2008 to 2017: A nationwide cohort study
  • 2020
  • Ingår i: Transfusion. - : WILEY. - 0041-1132 .- 1537-2995. ; 60:11, s. 2529-2536
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Transfusion patterns in Sweden have not been characterized on a nationwide level. Study Design and Methods We conducted a nationwide descriptive cohort study in Sweden from 2008 to 2017. Data on blood donors, donations, component manufacture, transfusions, and transfused patients were extracted from Swedish portion of the Scandinavian Donations and Transfusions (SCANDAT3-S) database. Results A total of 708 436 patients received 5 587 684 red cell, plasma, or platelet transfusions during the study period. The age-standardized transfusion rate decreased markedly during the study period for red cell units (from 53 to 39 units/1000 persons) and plasma units (from 11 to 4.9 units/1000 persons), but remained relatively constant for platelet concentrates. The transfusion rate was 30%-40% higher in males than in females in the first year of life, and higher in males over 45 years than in females. Between age 20 and 45, the majority of red cells were transfused to female patients with obstetric indications, whereas trauma was the predominant indication for male contemporaries. In females over 80 years, the largest proportion of red cells were administered due to trauma. Overall, hematological patients received 36% of all platelet units. There were large regional differences in transfusion rates for red cell units, ranging from less than 30 to greater than 60/1000 persons. Conclusion Transfusion rates in Sweden remain high but have decreased strikingly during the study period - with the exception of platelet transfusions. Based on the available data, it is difficult to draw firm conclusions about whether transfusion rates can be further reduced.
  •  
3.
  • Barro, Lassina, et al. (författare)
  • A double-virally-inactivated (Intercept-solvent/detergent) human platelet lysate for in vitro expansion of human mesenchymal stromal cells
  • 2019
  • Ingår i: Transfusion. - : John Wiley & Sons. - 0041-1132 .- 1537-2995. ; 59:6, s. 2061-2073
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND Pooled human platelet lysate (HPL) can replace fetal bovine serum (FBS) as xeno-free supplement for ex vivo expansion of mesenchymal stromal cells (MSCs). We evaluate here whether a double-virally-inactivated HPL (DVI-HPL) prepared from expired Intercept-treated platelet concentrates (PCs) and treated by solvent/detergent (S/D) can be used for MSC expansion. STUDY DESIGN AND METHODS Expired Intercept-treated PCs in 65% platelet (PLT) additive solution were pooled and subjected to a 1% tri-n-butyl phosphate/1% Triton X-45 treatment followed by soybean oil, hydrophobic interaction chromatography purification, and sterile filtration. Bone marrow-derived MSCs (BM-MSCs) were expanded for four passages in growth medium containing 10% DVI-HPL, I-HPL (from Intercept-PC only), untreated HPL, and FBS. MSC morphology, doubling time, immunophenotype, immunosuppressive activity, and differentiation capacity were compared. RESULTS Expanded cells had typical spindle morphology and showed higher viability in all HPL conditions than in FBS. The DVI-HPL and FBS-expanded cells were morphologically larger than in I-HPL and HPL supplements. The cumulative population doubling was lower using DVI-HPL than with HPL and I-HPL, but significantly higher than using FBS. Immunophenotype was not affected by the supplements used. Immunosuppressive activity was maintained with all supplements. Differentiation capacity into chondrocytes and osteocytes was more effective in DVI-HPL but less toward adipocytes compared to other supplements. CONCLUSIONS Human PLT lysate made from Intercept-PCs subjected to S/D treatment may be an alternative to untreated HPL and to I-HPL for BM-MSC expansion. This finding reinforces the potential of HPL as a virally safe alternative to FBS for clinical grade MSC expansion protocols.
  •  
4.
  • Berglund, David, et al. (författare)
  • Green plasma
  • 2015
  • Ingår i: Transfusion. - : Wiley. - 0041-1132 .- 1537-2995. ; 55:2, s. 245-245
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
  •  
5.
  • Edgren, Gustaf, et al. (författare)
  • Improving health profile of blood donors as a consequence of transfusion safety efforts
  • 2007
  • Ingår i: Transfusion. - : Wiley. - 0041-1132 .- 1537-2995. ; 47:11, s. 2017-2024
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Transfusion safety rests heavily on the health of blood donors. Although they are perceived as being healthier than average, little is known about their long-term disease patterns and to which extent the blood banks' continuous efforts to optimize donor selection has resulted in improvements. Mortality and cancer incidence among blood donors in Sweden and Denmark was investigated. Study Design and Methods: All computerized blood bank databases were compiled into one database, which was linked to national population and health data registers. With a retrospective cohort study design, 1,110,329 blood donors were followed for up to 35 years from first computer-registered blood donation to death, emigration, or December 31, 2002. Standardized mortality and incidence ratios expressed relative risk of death and cancer comparing blood donors to the general population. Results: Blood donors had an overall mortality 30 percent lower (99% confidence interval [CI] 29%-31%) and cancer incidence 4 percent lower (99% CI 2%-5%) than the background population. Mortality rates and cancer incidence were lowest for outcomes that are recognized as being related to lifestyle factors such as smoking or to the selection criteria for blood donation. Blood donors recruited in more recent years exhibited a lower relative mortality than those who started earlier. Conclusion: Blood donors enjoy better than average health. Explicit and informal requirements for blood donation in Scandinavia, although mostly of a simple nature, have successfully refined the selection of a particularly healthy subpopulation.
  •  
6.
  • Edgren, Gustaf, et al. (författare)
  • The new Scandinavian Donations and Transfusions database (SCANDAT2) : a blood safety resource with added versatility
  • 2015
  • Ingår i: Transfusion. - : Wiley. - 0041-1132 .- 1537-2995. ; 55:7, s. 1600-1606
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundRisks of transfusion-transmitted disease are currently at a record low in the developed world. Still, available methods for blood surveillance might not be sufficient to detect transmission of diseases with unknown etiologies or with very long incubation periods. Study Design and MethodsWe have previously created the anonymized Scandinavian Donations and Transfusions (SCANDAT) database, containing data on blood donors, blood transfusions, and transfused patients, with complete follow-up of donors and patients for a range of health outcomes. Here we describe the re-creation of SCANDAT with updated, identifiable data. We collected computerized data on blood donations and transfusions from blood banks covering all of Sweden and Denmark. After data cleaning, two structurally identical databases were created and the entire database was linked with nationwide health outcomes registers to attain complete follow-up for up to 47 years regarding hospital care, cancer, and death. ResultsAfter removal of erroneous records, the database contained 25,523,334 donation records, 21,318,794 transfusion records, and 3,692,653 unique persons with valid identification, presently followed over 40 million person-years, with possibility for future extension. Data quality is generally high with 96% of all transfusions being traceable to their respective donation(s) and a very high (>97%) concordance with official statistics on annual number of blood donations and transfusions. ConclusionsIt is possible to create a binational, nationwide database with almost 50 years of follow-up of blood donors and transfused patients for a range of health outcomes. We aim to use this database for further studies of donor health, transfusion-associated risks, and transfusion-transmitted disease.
  •  
7.
  •  
8.
  • Grau, Katrine, et al. (författare)
  • No association between frequent apheresis donation and risk of fractures : a retrospective cohort analysis from Sweden
  • 2017
  • Ingår i: Transfusion. - : Wiley. - 0041-1132 .- 1537-2995. ; 57:2, s. 390-396
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Citrate anticoagulation during apheresis induces transient alterations in calcium homeostasis. It is unknown whether the repeated, transient alterations in calcium homeostasis experienced by repeated apheresis donors affects bone turnover to increase fracture risk. Our aim was to investigate the risk of osteoporotic and nonosteoporotic fracture among voluntary, frequent apheresis donors. STUDY DESIGN AND METHODS: All apheresis donors were identified from the Scandinavian Donations and Transfusions database (SCANDAT2), which includes information on over 1.6 million blood donors from Sweden and Denmark from the years 1968 and 1981, respectively. Only data from Sweden were used for these analyses. Information on fractures was obtained by linking SCANDAT2 to hospital registers. Poisson regression was used to compute incidence rate ratios of fractures in relation to the cumulative number of apheresis donations, both overall and in fixed time windows. RESULTS: In total, 140,289 apheresis donors (67,970 women and 72,319 men) were identified from the SCANDAT2 database and were followed for up to 23 years. We observed no association between the frequency of apheresis donation and the risk of fracture either in the overall study period or during fixed-length time windows. The incidence rate ratio of fractures in donors who had made 100 or more cumulative apheresis donations was 0.99(95% confidence interval, 0.92-1.06) compared with donors who had made from 9 to 24 donations. The results were similar in analyses stratified by sex and restricted to postmenopausal women. CONCLUSIONS: The absence of an association between repeated apheresis donation and fracture risk indicates that apheresis collection is safe with regard to bone health.
  •  
9.
  •  
10.
  • Högman, Claes F., et al. (författare)
  • Storage of red blood cells with improved maintenance of 2,3-bisphosphoglycerate
  • 2006
  • Ingår i: Transfusion. - : Wiley. - 0041-1132 .- 1537-2995. ; 46:9, s. 1543-1552
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: During storage, red blood cells (RBCs) rapidly lose 2,3-bisphosphoglycerate (2,3-DPG) leading to an increase in the affinity for O-2 and a temporary impairment of O-2 transport. Recent clinical evaluations indicate that the quality of transfused RBCs may be more important for patient survival than previously recognized. STUDY DESIGN AND METHODS: Glucose-free additive solutions (ASs) were prepared with sodium citrate, sodium gluconate, adenine, mannitol, and phosphates at high pH, a solution that can be heat-sterilized. CP2D was used as an anticoagulant. Additional CP2D was added to the AS to supply glucose. RBCs were stored at 4 degrees C and assayed periodically for intracellular pH (pHi), extracellular pH, glucose, lactate, phosphate, ATP, 2,3-DPG, hemolysis, and morphology. RESULTS: Storage in 175 mL of the chloride-free, hypotonic medium at a hematocrit (Hct) level of 59 to 60 percent resulted in an elevated pHi and the maintenance of 2,3-DPG at or above the initial value for 2 weeks without loss of ATP. The addition of 400 mL of storage solution followed by centrifugation and removal of 300 mL of excess solution to a Hct level of 60 to 66 percent further reduced the chloride concentration, resulting in the maintenance of 2,3-DPG for 4 weeks. Hemolysis was at 0.1 percent at 6 weeks. CONCLUSION: Improvements in the maintenance of 2,3-DPG were achieved with 175 mL of a chloride-free storage solution with familiar additives at nontoxic concentrations to increase pHi. Adding, instead, 400 mL of storage solution followed by the removal of 300 mL reduced the chloride concentration, increasing the pHi and extending the maintenance of 2,3-DPG to 4 weeks.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 26

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy