SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0094 2405 OR L773:2473 4209 ;hsvcat:1"

Sökning: L773:0094 2405 OR L773:2473 4209 > Naturvetenskap

  • Resultat 1-10 av 91
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Giantsoudi, D., et al. (författare)
  • A gEUD-based inverse planning technique for HDR prostate brachytherapy : Feasibility study
  • 2013
  • Ingår i: Medical physics (Lancaster). - : Wiley. - 0094-2405 .- 2473-4209. ; 40:4, s. 041704-
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The purpose of this work was to study the feasibility of a new inverse planning technique based on the generalized equivalent uniform dose for image-guided high dose rate (HDR) prostate cancer brachytherapy in comparison to conventional dose-volume based optimization. Methods: The quality of 12 clinical HDR brachytherapy implants for prostate utilizing HIPO (Hybrid Inverse Planning Optimization) is compared with alternative plans, which were produced through inverse planning using the generalized equivalent uniform dose (gEUD). All the common dose-volume indices for the prostate and the organs at risk were considered together with radiobiological measures. The clinical effectiveness of the different dose distributions was investigated by comparing dose volume histogram and gEUD evaluators. Results: Our results demonstrate the feasibility of gEUD-based inverse planning in HDR brachytherapy implants for prostate. A statistically significant decrease in D-10 or/and final gEUD values for the organs at risk (urethra, bladder, and rectum) was found while improving dose homogeneity or dose conformity of the target volume. Conclusions: Following the promising results of gEUD-based optimization in intensity modulated radiation therapy treatment optimization, as reported in the literature, the implementation of a similar model in HDR brachytherapy treatment plan optimization is suggested by this study. The potential of improved sparing of organs at risk was shown for various gEUD-based optimization parameter protocols, which indicates the ability of this method to adapt to the user's preferences.
  •  
2.
  • Kjellsson Lindblom, Emely, et al. (författare)
  • Impact of SBRT fractionation in hypoxia dose painting - accounting for heterogeneous and dynamic tumour oxygenation
  • 2019
  • Ingår i: Medical physics (Lancaster). - : Wiley. - 0094-2405 .- 2473-4209. ; 46:5, s. 2512-2521
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeTumor hypoxia, often found in nonsmall cell lung cancer (NSCLC), implies an increased resistance to radiotherapy. Pretreatment assessment of tumor oxygenation is, therefore, warranted in these patients, as functional imaging of hypoxia could be used as a basis for dose painting. This study aimed at investigating the feasibility of using a method for calculating the dose required in hypoxic subvolumes segmented on 18F‐HX4 positron emission tomography (PET) imaging of NSCLC.MethodsPositron emission tomography imaging data based on the hypoxia tracer 18F‐HX4 of 19 NSCLC patients were included in the study. Normalized tracer uptake was converted to oxygen partial pressure (pO2) and hypoxic target volumes (HTVs) were segmented using a threshold of 10 mmHg. Uniform doses required to overcome the hypoxic resistance in the target volumes were calculated based on a previously proposed method taking into account the effect of interfraction reoxygenation, for fractionation schedules ranging from extremely hypofractionated stereotactic body radiotherapy (SBRT) to conventionally fractionated radiotherapy.ResultsGross target volumes ranged between 6.2 and 859.6 cm3, and the hypoxic fraction < 10 mmHg between 1.2% and 72.4%. The calculated doses for overcoming the resistance of cells in the HTVs were comparable to those currently prescribed in clinical practice as well as those previously tested in feasibility studies on dose escalation in NSCLC. Depending on the size of the HTV and the distribution of pO2, HTV doses were calculated as 43.6–48.4 Gy for a three‐fraction schedule, 51.7–57.6 Gy for five fractions, and 59.5–66.4 Gy for eight fractions. For patients in whom the HTV pO2 distribution was more favorable, a lower dose was required despite a bigger volume. Tumor control probability was lower for single‐fraction schedules, while higher levels of tumor control probability were found for schedules employing several fractions.ConclusionsThe method to account for heterogeneous and dynamic hypoxia in target volume segmentation and dose prescription based on 18F‐HX4‐PET imaging appears feasible in NSCLC patients. The distribution of oxygen partial pressure within HTV could impact the required prescribed dose more than the size of the volume.
  •  
3.
  • Liamsuwan, Thiansin, et al. (författare)
  • Microdosimetry of proton and carbon ions
  • 2014
  • Ingår i: Medical physics (Lancaster). - : Wiley. - 0094-2405 .- 2473-4209. ; 41:8, s. 239-250
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To investigate microdosimetry properties of 160 MeV/u protons and 290 MeV/u C-12 ion beams in small volumes of diameters 10-100 nm. Methods: Energy distributions of primary particles and nuclear fragments in the beams were calculated from simulations with the general purpose code SHIELD-HIT, while energy depositions by monoenergetic ions in nanometer volumes were obtained from the event-by-event Monte Carlo track structure ion code PITS99 coupled with the electron track structure code KURBUC. Results: The results are presented for frequencies of energy depositions in cylindrical targets of diameters 10-100 nm, dose distributions (y) over bar (D) in lineal energy y, and dose-mean lineal energies YD For monoenergetic ions, the hp was found to increase with an increasing target size for high-linear energy transfer (LET) ions, but decrease with an increasing target size for low-LET ions. Compared to the depth dose profile of the ion beams, the maximum of the hp depth profile for the 160 MeV proton beam was located at similar to 0.5 cm behind the Bragg peak maximum, while the PD peak of the 290 MeV/u C-12 beam coincided well with the peak of the absorbed dose profile. Differences between the (y) over bar (D) and dose-averaged linear energy transfer (LETD) were large in the proton beam for both target volumes studied, and in the C-12 beam for the 10 nm diameter cylindrical volumes. The (y) over bar (D) determined for 100 run diameter cylindrical volumes in the C-12 beam was approximately equal to the LETD. The contributions from secondary particles to the (y) over bar (D) of the beams are presented, including the contributions from secondary protons in the proton beam and from fragments with atomic number Z = 1-6 in the C-12 beam. Conclusions: The present investigation provides an insight into differences in energy depositions in subcellular-size volumes when irradiated by proton and carbon ion beams. The results are useful for characterizing ion beams of practical importance for biophysical modeling of radiation-induced DNA damage response and repair in the depth profiles of protons and carbon ions used in radiotherapy.
  •  
4.
  • Näsmark, Torbjörn, 1986-, et al. (författare)
  • Proton stopping power prediction based on dual-energy CT-generated virtual mono-energetic images
  • 2021
  • Ingår i: Medical physics (Lancaster). - : John Wiley & Sons. - 0094-2405 .- 2473-4209. ; 48:9, s. 5232-5243
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The purpose of this work was to assess a proof of concept for a novel method for predicting proton stopping power ratios (SPRs) based on a pair of dual-energy CT generated virtual monoenergetic (VM) images.Materials and methods: A rapid kV-switching dual-energy CT scanner was used to acquire Gemstone Spectral Imaging (GSI) and 120 kV conventional single-energy CT (SECT) image data of the CIRS 062M phantom. The proposed method was applied to every possible pairing of VM images between 40 and 140 keV to find the optimal energy pairs for SPR prediction in lung tissue, soft tissue, and bone. The predicted SPRs were compared against SPRs predicted from the SECT data using the conventional SECT-based method. The impact of different scan and reconstruction parameters was also investigated.Results: The SPR residual root mean square errors (RMSE) yielded by the optimal pairs were 7.2% for lung tissue, 0.4% for soft tissue, and 0.8% for bone. While no direct comparison could be made to other DECT-based methods for SPR prediction, as these methods could not be directly implemented on a fast kV-switching system, the SPR RMSEs for soft tissue and bone in Table 4 are comparable to RMSEs reported in the literature. For the conventional SECT-based method, the SPR RMSEs were 5.9% for lung tissue, 0.9% for soft tissue, and 5.1% for bone.Conclusions: The proposed method is a valid alternative to, and has the potential to improve upon, the conventional SECT-based method for predicting SPRs. The formalism used in the method is applied directly, with no approximations made on our part, and requires neither prior knowledge of the spectra nor calibration with a phantom. This work presents a way of optimizing the proposed method for a specific scanner by determining the optimal energy pairs to use as input and demonstrates the method's robustness to different levels of ASiR-V, reconstruction kernels, and dose levels.
  •  
5.
  • Ödén, Jakob, et al. (författare)
  • Inclusion of a variable RBE into proton and photon plan comparison for various fractionation schedules in prostate radiation therapy
  • 2017
  • Ingår i: Medical physics (Lancaster). - : Wiley. - 0094-2405 .- 2473-4209. ; 44:3, s. 810-822
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: A constant relative biological effectiveness (RBE) of 1.1 is currently used in proton radiation therapy to account for the increased biological effectiveness compared to photon therapy. However, there is increasing evidence that proton RBE vary with the linear energy transfer (LET), the dose per fraction and the type of the tissue. Therefore, this study aims to evaluate the impact of disregarding variations in RBE when comparing proton and photon dose plans for prostate treatments for various fractionation schedules using published RBE models and several α/β assumptions.Methods: Photon and proton dose plans were created for three generic prostate cancer cases. Three BED3Gy equivalent schedules were studied, 78, 57.2 and 42.8 Gy in 39, 15 and 7 fractions, respectively. The proton plans were optimized assuming a constant RBE of 1.1. By using the Monte Carlo calculated dose-averaged LET (LETd) distribution and assuming α/β values on voxel level, three variable RBE models were applied to the proton dose plans. The impact of the variable RBE was studied in the plan comparison, which was based on the dose distribution, DVHs and normal tissue complication probabilities (NTCP) for the rectum. Subsequently, the physical proton dose was re-optimized for each proton plan based on the LETd distribution, to achieve a homogeneous RBE weighted target dose when applying a specific RBE model and still fulfil the clinical goals for the rectum and bladder.Results: All the photon and proton plans assuming RBE=1.1 met the clinical goals with similar target coverage. The proton plans fulfilled the robustness criteria in terms of range and setup uncertainty. Applying the variable RBE models generally resulted in higher target doses and rectum NTCP compared to the photon plans. The increase was most pronounced for the fractionation dose of 2 Gy(RBE) whereas it was of less magnitude and more dependent on model and α/β assumption for the hypofractionated schedules. The re-optimized proton plans proved to be robust and showed similar target coverage and doses to the organs at risk as the proton plans optimized with a constant RBE.Conclusions: Model predicted RBE values may differ substantially from 1.1. This is most pronounced for fractionation doses of around 2 Gy(RBE) with higher doses to the target and the OARs, whereas the effect seems to be of less importance for the hypofractionated schedules. This could result in misleading conclusions when comparing proton plans to photon plans. By accounting for a variable RBE in the optimization process, robust and clinically acceptable dose plans, with the potential of lowering rectal NTCP, may be generated by re-optimizing the physical dose. However, the direction and magnitude of the changes in the physical proton dose to the prostate are dependent on RBE model and α/β assumptions and should therefore be used conservatively.
  •  
6.
  • Bayisa, Fekadu, et al. (författare)
  • Statistical learning in computed tomography image estimation
  • 2018
  • Ingår i: Medical physics (Lancaster). - : John Wiley & Sons. - 0094-2405 .- 2473-4209. ; 45:12, s. 5450-5460
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: There is increasing interest in computed tomography (CT) image estimations from magneticresonance (MR) images. The estimated CT images can be utilized for attenuation correction, patientpositioning, and dose planning in diagnostic and radiotherapy workflows. This study aims to introducea novel statistical learning approach for improving CT estimation from MR images and to compare theperformance of our method with the existing model-based CT image estimation methods.Methods: The statistical learning approach proposed here consists of two stages. At the trainingstage, prior knowledge about tissue types from CT images was used together with a Gaussian mixturemodel (GMM) to explore CT image estimations from MR images. Since the prior knowledge is notavailable at the prediction stage, a classifier based on RUSBoost algorithm was trained to estimatethe tissue types from MR images. For a new patient, the trained classifier and GMMs were used topredict CT image from MR images. The classifier and GMMs were validated by using voxel-leveltenfold cross-validation and patient-level leave-one-out cross-validation, respectively.Results: The proposed approach has outperformance in CT estimation quality in comparison withthe existing model-based methods, especially on bone tissues. Our method improved CT image estimationby 5% and 23% on the whole brain and bone tissues, respectively.Conclusions: Evaluation of our method shows that it is a promising method to generate CTimage substitutes for the implementation of fully MR-based radiotherapy and PET/MRI applications
  •  
7.
  • Eriksson, O., et al. (författare)
  • Robust automated radiation therapy treatment planning using scenario-specific dose prediction and robust dose mimicking
  • 2022
  • Ingår i: Medical physics (Lancaster). - : Wiley. - 0094-2405 .- 2473-4209. ; 49:6, s. 3564-3573
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: We present a framework for robust automated treatment planning using machine learning, comprising scenario-specific dose prediction and robust dose mimicking. Methods: The scenario dose prediction pipeline is divided into the prediction of nominal dose from input image and the prediction of scenario dose from nominal dose, each using a deep learning model with U-net architecture. By using a specially developed dose–volume histogram–based loss function, the predicted scenario doses are ensured sufficient target coverage despite the possibility of the training data being non-robust. Deliverable plans may then be created by solving a robust dose mimicking problem with the predictions as scenario-specific reference doses. Results: Numerical experiments are performed using a data set of 52 intensity-modulated proton therapy plans for prostate patients. We show that the predicted scenario doses resemble their respective ground truth well, in particular while having target coverage comparable to that of the nominal scenario. The deliverable plans produced by the subsequent robust dose mimicking were showed to be robust against the same scenario set considered for prediction. Conclusions: We demonstrate the feasibility and merits of the proposed methodology for incorporating robustness into automated treatment planning algorithms. 
  •  
8.
  • Gotz, Malte, et al. (författare)
  • Correction for volume recombination in liquid ionization chambers at high dose-per-pulse
  • 2019
  • Ingår i: Medical physics (Lancaster). - : WILEY. - 0094-2405 .- 2473-4209. ; 46:8, s. 3692-3699
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose To determine the volume recombination at high dose-per-pulse in liquid ionization chambers (LIC) and to ascertain whether existing calculation methods verified in air-filled chambers may be used to calculate a correction factor. Methods Two LICs, one filled with 2,2,4-trimethylpentane (isooctane) the other with tetramethylsilane (TMS), were irradiated in a pulsed, 20 MeV electron beam. Via reference measurements with a Faraday cup, the saturation correction for volume recombination was determined for dose-per-pulse values ranging from about 5 mGy to 1 Gy for both chambers at a pulse duration of 693 ns. In addition, the isooctane chamber was irradiated with pulses of varying duration, ranging from 5 ps to 10 ms, at a dose-per-pulse of about 76.5 mGy. The dose-per-pulse-dependent measurements were compared to calculations based on Boag's models (with and without a free electron fraction), the two-dose-rate method, and a numerical calculation. The pulse duration dependent measurements were compared only to a numerical calculation that iteratively calculates the charge transport and loss in a 1D model of an ionization chamber. Results In TMS only Boag's model with a free electron fraction and the numerical calculation are in good agreement with the experimental data. However, in isooctane, good agreement is observed between the experimental data, the numerical calculation as well as the two-dose-rate method, and Boag's model including a free electron fraction. Only Boag's model without a free electron fraction shows a good agreement with lesser extend. Furthermore, the pulse duration-dependent data for isooctane are well described by the numerical model. Conclusion With isooctane as an active medium, a LIC could be directly used in a field with high dose-per-pulse utilizing the well-established two-dose-rate method to correct the volume recombination. In addition, pulsed fields with variable pulse duration are easily modeled for this medium using a numerical calculation. Other media, as exemplified by the TMS-filled chamber, might require additional considerations, such as including a fraction of free electrons in the consideration of volume recombination.
  •  
9.
  • Larsson, Daniel H., et al. (författare)
  • First application of liquid-metal-jet sources for small-animal imaging : High-resolution CT and phase-contrast tumor demarcation
  • 2013
  • Ingår i: Medical physics (Lancaster). - : Wiley. - 0094-2405 .- 2473-4209. ; 40:2, s. 021909-
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Small-animal studies require images with high spatial resolution and high contrast due to the small scale of the structures. X-ray imaging systems for small animals are often limited by the microfocus source. Here, the authors investigate the applicability of liquid-metal-jet x-ray sources for such high-resolution small-animal imaging, both in tomography based on absorption and in soft-tissue tumor imaging based on in-line phase contrast. Methods: The experimental arrangement consists of a liquid-metal-jet x-ray source, the small-animal object on a rotating stage, and an imaging detector. The source-to-object and object-to-detector distances are adjusted for the preferred contrast mechanism. Two different liquid-metal-jet sources are used, one circulating a Ga/In/Sn alloy and the other an In/Ga alloy for higher penetration through thick tissue. Both sources are operated at 40-50 W electron-beam power with similar to 7 mu m x-ray spots, providing high spatial resolution in absorption imaging and high spatial coherence for the phase-contrast imaging. Results: High-resolution absorption imaging is demonstrated on mice with CT, showing 50 mu m bone details in the reconstructed slices. High-resolution phase-contrast soft-tissue imaging shows clear demarcation of mm-sized tumors at much lower dose than is required in absorption. Conclusions: This is the first application of liquid-metal-jet x-ray sources for whole-body small-animal x-ray imaging. In absorption, the method allows high-resolution tomographic skeletal imaging with potential for significantly shorter exposure times due to the power scalability of liquid-metal-jet sources. In phase contrast, the authors use a simple in-line arrangement to show distinct tumor demarcation of few-mm-sized tumors. This is, to their knowledge, the first small-animal tumor visualization with a laboratory phase-contrast system.
  •  
10.
  • Morén, Björn, 1987-, et al. (författare)
  • An extended dose-volume model in high dose-rate brachytherapy : Using mean-tail-dose to reduce tumor underdosage
  • 2019
  • Ingår i: Medical physics (Lancaster). - : Wiley-Blackwell Publishing Inc.. - 0094-2405 .- 2473-4209. ; 46:6, s. 2556-2566
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose High dose-rate brachytherapy is a method of radiotherapy for cancer treatment in which the radiation source is placed within the body. In addition to give a high enough dose to a tumor, it is also important to spare nearby healthy organs [organs at risk (OAR)]. Dose plans are commonly evaluated using the so-called dosimetric indices; for the tumor, the portion of the structure that receives a sufficiently high dose is calculated, while for OAR it is instead the portion of the structure that receives a sufficiently low dose that is of interest. Models that include dosimetric indices are referred to as dose-volume models (DVMs) and have received much interest recently. Such models do not take the dose to the coldest (least irradiated) volume of the tumor into account, which is a distinct weakness since research indicates that the treatment effect can be largely impaired by tumor underdosage even to small volumes. Therefore, our aim is to extend a DVM to also consider the dose to the coldest volume. Methods An improved DVM for dose planning is proposed. In addition to optimizing with respect to dosimetric indices, this model also takes mean dose to the coldest volume of the tumor into account. Results Our extended model has been evaluated against a standard DVM in ten prostate geometries. Our results show that the dose to the coldest volume could be increased, while also computing times for the dose planning were improved. Conclusion While the proposed model yields dose plans similar to other models in most aspects, it fulfils its purpose of increasing the dose to cold tumor volumes. An additional benefit is shorter solution times, and especially for clinically relevant times (of minutes) we show major improvements in tumour dosimetric indices.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 91
Typ av publikation
tidskriftsartikel (89)
doktorsavhandling (1)
forskningsöversikt (1)
Typ av innehåll
refereegranskat (84)
övrigt vetenskapligt/konstnärligt (7)
Författare/redaktör
Knöös, Tommy (10)
Ceberg, Crister (9)
Ahnesjö, Anders (6)
Nilsson, Per (5)
Ljungberg, Michael (5)
Forsgren, Anders (5)
visa fler...
Carlsson Tedgren, Ås ... (4)
Strand, Sven-Erik (4)
Weber, Lars (4)
Traneus, Erik (4)
Andersson, Jonas, 19 ... (4)
Mavroidis, Panayioti ... (3)
Petersson, Kristoffe ... (3)
Maguire Jr., Gerald ... (3)
Noz, Marilyn E. (3)
Toma-Daşu, Iuliana (3)
Engström, Per (3)
Tingberg, Anders (3)
Andersson, Ingvar (3)
Timberg, Pontus (3)
Tölli, Heikki (3)
Bjärngard, Bengt E (3)
Bokrantz, Rasmus (3)
Ceberg, Sofie (2)
Andersson-Engels, St ... (2)
Karlsson, Mikael (2)
Garpebring, Anders (2)
Mattsson, Sören (2)
Carlsson Tedgren, Ås ... (2)
Saxner, Mikael (2)
Kügele, Malin (2)
Danielsson, Mats (2)
Båth, Magnus, 1974 (2)
Carlsson, Fredrik (2)
Dasu, Alexandru (2)
Carlsson, F. (2)
Asklund, Thomas (2)
Maki, Atsuto (2)
Yu, Jun, 1962- (2)
Fredriksson, Albin (2)
Sjögreen Gleisner, K ... (2)
Cederström, Björn (2)
Gustafsson, Helen (2)
Hult, Henrik, 1975- (2)
Dalaryd, Mårten (2)
De Wagter, C (2)
Nordström, Marcus (2)
Johnsson, Stefan (2)
Åslund, Magnus (2)
Georg, Dietmar (2)
visa färre...
Lärosäte
Lunds universitet (41)
Kungliga Tekniska Högskolan (21)
Karolinska Institutet (14)
Stockholms universitet (10)
Umeå universitet (9)
Uppsala universitet (7)
visa fler...
Linköpings universitet (7)
Göteborgs universitet (4)
Chalmers tekniska högskola (1)
Sveriges Lantbruksuniversitet (1)
visa färre...
Språk
Engelska (91)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (32)
Teknik (7)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy