SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0095 1137 ;pers:(Rubin Carl Johan)"

Sökning: L773:0095 1137 > Rubin Carl Johan

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Herrmann, Björn, et al. (författare)
  • Comparison of a duplex quantitative real-time PCR assay and the COBAS Amplicor CMV Monitor test for detection of cytomegalovirus
  • 2004
  • Ingår i: Journal of Clinical Microbiology. - 0095-1137 .- 1098-660X. ; 42:5, s. 1909-14
  • Tidskriftsartikel (refereegranskat)abstract
    • A duplex quantitative real-time PCR (qPCR) assay was designed to detect both the polymerase gene (pol) and the glycoprotein gene (gB) of cytomegalovirus (CMV). The detection limit of the qPCR was determined to be 1 to 3 copies/reaction and the linear measure interval was 10(3) to 10(8) copies/ml. The qPCR system was compared to the COBAS Amplicor CMV Monitor test (COBAS) by an analysis of 138 plasma samples. Both systems detected CMV in 71 cases and had negative results for 33 samples. In addition, 34 samples were positive by qPCR and negative by the COBAS assay, but in no case was the COBAS result positive and the qPCR result negative. Thus, qPCR detected 48% more positive cases than the COBAS method. For samples with > or = 10(5) copies/ml by qPCR, a saturation effect was seen in the COBAS assay and quantification required dilution. Copy numbers for pol and gB by qPCR generally agreed. However, the reproducibility of qPCR assays and the need for an international standard are discussed. Discrepant copy numbers for pol and gB by qPCR were found for samples from two patients, and sequence analysis revealed that the corresponding CMV strains were mismatched at four nucleotide positions compared with the gB fragment primer sequences. In conclusion, a duplex qPCR assay in a real-time format facilitates quantitative measurements and minimizes the risk of false-negative results.
  •  
2.
  • Innings, Åsa, et al. (författare)
  • Multiplex real-time PCR targeting the RNase P RNA gene for detection and identification of Candida species in blood
  • 2007
  • Ingår i: Journal of Clinical Microbiology. - 0095-1137 .- 1098-660X. ; 45:3, s. 874-880
  • Tidskriftsartikel (refereegranskat)abstract
    • We have developed a single-tube multiplex real-time PCR method for the detection of the eight most common Candida species causing septicemia: Candida albicans, C. dubliniensis, C. famata, C. glabrata, C. guilliermondii, C. krusei, C. parapsilosis, and C. tropicalis. The method developed targets the RNase P RNA gene RPR1. Sequences of this geiie were determined for seven of the Candida species and showed surprisiRgly large sequence variation. C. glabrata was found to have a gene that was five times longer gene than those of the other species, and the nucleotide sequence similarity between C. krusei and C. albicans was as low as 55%. The multiplex PCR contained three probes that enabled the specific detection of C. albicans, C. glabrata, and C. krusei and a fourth probe that allowed the general detection of the remaining species. The method was able to detect 1 to 10 genome copies when the detection limit was tested repeatedly for the four species C. albicans, C. glabrata, C. krusei, and C. guilliermondii. No significant difference in the detection limit was seen when the multiplex format was compared with single-species PCR, i.e., two primers and one probe. The method detected eight clinically relevant Candida species and did not react with other tested non-Candida species or human DNA. The assay was applied to 20 blood samples from nine patients and showed a sensitivity similar to that of culture.
  •  
3.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy