SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0095 1137 ;pers:(Staum Kaltoft Margit)"

Sökning: L773:0095 1137 > Staum Kaltoft Margit

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Strålin, Kristoffer, 1969-, et al. (författare)
  • Comparison of two urinary antigen tests for establishment of pneumococcal etiology of adult community-acquired pneumonia
  • 2004
  • Ingår i: Journal of Clinical Microbiology. - 0095-1137 .- 1098-660X. ; 42:8, s. 3620-3625
  • Tidskriftsartikel (refereegranskat)abstract
    • The Binax NOW immunochromatographic test (ICT) detecting the pneumococcal C polysaccharide and a serotype-specific latex agglutination (LA) test detecting 23 pneumococcal capsular antigens were evaluated for establishing pneumococcal etiology in community-acquired pneumonia (CAP) by use of nonconcentrated urine. ICT was considered to be strongly positive for result lines at least as intense as the control line and weakly positive for less intense result lines. When 215 adult CAP patients were tested, strong ICT, weak ICT, and LA positivity were found in 28, 24, and 16 patients, respectively; of these patients, 13 (46%), 6 (25%), and 13 (81%), respectively, had pneumococcal bacteremia and 27 (96%), 17 (71%), and 15 (94%), respectively, had Streptococcus pneumoniae isolated from blood, sputum, and/or nasopharynx. Among 108 controls tested, 2 (1.9%) were weakly ICT positive. When weak positivity was considered negative, the sensitivity of ICT decreased from 79% (19 of 24) to 54% (13 of 24), while the specificity increased from 83% (158 of 191) to 92% (176 of 191); no controls were false positive. The sensitivity and specificity of LA were 54% (13 of 24) and 98% (188 of 191), respectively. Eight of nine LA serotypes corresponded to culture serotypes. In conclusion, using nonconcentrated urine and dividing ICT-positive results into strongly and weakly positive results is a suitable way of performing ICT. While weak ICT positivity should be interpreted with caution, strong ICT positivity and LA positivity should be considered supportive of pneumococcal etiology in adult CAP. As such, these assays might have implications for antibiotic use in CAP. LA has promising potential for pneumococcal serotyping, although further evaluation is required.
  •  
2.
  • Strålin, Kristoffer, 1969-, et al. (författare)
  • Etiologic diagnosis of adult bacterial pneumonia by culture and PCR applied to respiratory tract samples
  • 2006
  • Ingår i: Journal of Clinical Microbiology. - 0095-1137 .- 1098-660X. ; 44:2, s. 643-645
  • Tidskriftsartikel (refereegranskat)abstract
    • Respiratory culture and multiplex PCR for Streptococcus pneumoniae, Haemophilus influenzae, Mycoplasma pneumoniae, and Chlamydophila pneumoniae were applied to sputum, nasopharyngeal swabs, and nasopharyngeal aspirates from 235 adult patients with community-acquired pneumonia and 113 controls. Both culture and multiplex PCR performed well with the different samples and appear to be useful as diagnostic tools.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Holmberg, Hans (2)
Olcén, Per, 1943- (2)
Strålin, Kristoffer, ... (2)
Törnqvist, Eva (1)
Bossen Konradsen, He ... (1)
Lärosäte
Linköpings universitet (2)
Språk
Engelska (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy