SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0168 9002 OR L773:1872 9576 ;lar1:(lnu)"

Sökning: L773:0168 9002 OR L773:1872 9576 > Linnéuniversitetet

  • Resultat 1-10 av 27
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Adiels, Lars, et al. (författare)
  • A π0 and η spectrometer of lead glass and BGO for momenta up to 1 GeV/c
  • 1986
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 244:3, s. 380-390
  • Tidskriftsartikel (refereegranskat)abstract
    • A spectrometer consisting of two sets of bismuth germanium oxide (BGO) crystals and a lead-glass array has been used to measure the [pi]0 and [eta] momentum spectra produced from proton-antiproton annihilations at rest. We describe the test of the BGO sets in electron beams of energies from 50 to 450 MeV. We discuss the method of construction and calibration of the lead-glass array, as well as procedures to extract the energy and position resolutions for detected photons. A momentum resolution ([sigma]) for [pi]0’s and [eta]’s of 4% and 3%, respectively has been achieved at momenta below 1 GeV/c.
  •  
2.
  • Ambrosio, M, et al. (författare)
  • Muon energy estimate through multiple scattering with the MACRO detector
  • 2002
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 492:3, s. 376-386
  • Tidskriftsartikel (refereegranskat)abstract
    • Muon energy measurement represents an important issue for any experiment addressing neutrino-induced up-going muon studies. Since the neutrino oscillation probability depends on the neutrino energy, a measurement of the muon energy adds an important piece of information concerning the neutrino system. We show in this paper how the MACRO limited streamer tube system can be operated in drift mode by using the TDCs included in the QTPs, an electronics designed for magnetic monopole search. An improvement of the space resolution is obtained, through an analysis of the multiple scattering of muon tracks as they pass through our detector. This information can be used further to obtain an estimate of the energy of muons crossing the detector. Here we present the results of two dedicated tests, performed at CERN PS-T9 and SPS-X7 beam lines, to provide a full check of the electronics and to exploit the feasibility of such a multiple scattering analysis. We show that by using a neural network approach, we are able to reconstruct the muon energy for E-mu < 40 GeV. The test beam data provide an absolute energy calibration, which allows us to apply this method to MACRO data. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
3.
  • Ambrosio, M, et al. (författare)
  • The MACRO detector at Gran Sasso
  • 2002
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 486:3, s. 663-707
  • Tidskriftsartikel (refereegranskat)abstract
    • MACRO was an experiment that ran in the Laboratori Nazionali del Gran Sasso from 1988 to 2000. Its principal goal was to observe magnetic monopoles or set significantly lower experimental flux limits than had been previously available in the velocity range from about beta = 10(-4) to unity. In addition it made a variety of other observations. Examples are: setting flux limits on other so far unobserved particles such as nuclearites and lightly ionizing particles, searching for WIMP annihilations in the Earth and the Sun and for neutrino bursts from stellar collapses in or near our Galaxy, and making measurements relevant to high energy muon and neutrino astronomy and of the flux of up-going muons as a function of nadir angle showing evidence for neutrino oscillations. The apparatus consisted of three principal types of detectors: liquid scintillator counters, limited streamer tubes, and nuclear track etch detectors. In addition, over part of its area it contained a transition radiation detector. The general design philosophy emphasized redundancy and complementarity. This paper describes the technical aspects of the complete MACRO detector, its operational performance, and the techniques used to calibrate it and verify its proper operation. It supplements a previously published paper which described the first portion of the detector that was built and operated. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
4.
  • Armijo, V., et al. (författare)
  • A fast MWPC with cathode strips and utilizing CF4-isobutane
  • 1991
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 303:2, s. 298-308
  • Tidskriftsartikel (refereegranskat)abstract
    • A planar wire chamber has been developed at LAMPF as a prototype for wire chambers of cylindrical configuration for electron detection in the MEGA experiment. Results form tests with the planar chamber have been used to set the geometrical parameters and predict the performance characteristics of the cylindrical chambers. The behavior of the planar chamber with CF4-isobutane gas demonstrates that 15 μm wire of 1 mm pitch is practical, that lifetimes greater than 0.045 C/cm are achievable and that gate widths of 25 ns are possible. © 1991.
  •  
5.
  • Calén, H., et al. (författare)
  • Detector setup for a storage ring with an internal target
  • 1996
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 379:1, s. 57-75
  • Tidskriftsartikel (refereegranskat)abstract
    • A detector setup for the cooler storage ring CELSIUS is described. The setup detects particles produced in interactions between the internal beam and a cluster-jet target. Particles emitted in the forward direction are measured by means of arrays of plastic scintillators and proportional counters. Particles, particularly photons, emitted more isotropically are measured by means of two calorimeters containing CsI(Na) crystals. The performance of the setup is given for neutral meson production in proton-proton and proton-deuteron interactions in the energy range 290-1360 MeV.
  •  
6.
  • Cooper, M. D., et al. (författare)
  • Construction and performance of MEGA's low-mass, high-rate cylindrical MWPCs
  • 1998
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 417:1, s. 24-49
  • Tidskriftsartikel (refereegranskat)abstract
    • A design for extremely low mass, high-resolution multiwire proportional chambers (MWPC) was achieved by the MEGA collaboration in its experiment to search for the lepton family number violating decay μ → eγ. To extend the present branching ratio limit by over an order of magnitude, these MWPCs were operated in high particle fluxes. They showed minimal effects of aging, and evidenced spatial and energy resolutions for the orbiting positrons from muon decay which were consistent with our design parameters. The unique features of these chambers, their assembly into the MEGA positron spectrometer, and their performance during the experiment are described in this paper.
  •  
7.
  • Stanislaus, S., et al. (författare)
  • Results from beam tests of MEGA's low-mass, high-rate cylindrical MWPCs
  • 1992
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 323:1-2, s. 198-202
  • Tidskriftsartikel (refereegranskat)abstract
    • One of the leading experimental projects at LAMPF has been the MEGA experiment. This is an experiment to search for the rare decay μ → eγ with a sensitivity of 10-13. A prime component of this project has been the design and construction of high-rate, low-mass MWPCs for the tracking of positrons from muon decay. With rate capabilities of 2 × 104 e+/mm2/s and a thickness of 3 × 10-4 radiation lengths, these chambers are state-of-the-art cylindrical MWPCs. Cylindrical chambers of this size (0.9 m2) and thinness have never been previously constructed. The MEGA project at LAMPF has recently succeeded in building chambers with these necessary performance characteristics as demonstrated by data taken from muon decays, cosmic rays, and sources. © 1992.
  •  
8.
  • Abbasi, R., et al. (författare)
  • Calibration and characterization of the IceCube photomultiplier tube
  • 2010
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 618:1-3, s. 139-152
  • Tidskriftsartikel (refereegranskat)abstract
    • Over 5000 PMTs are being deployed at the South Pole to compose the IceCube neutrino observatory. Many are placed deep in the ice to detect Cherenkov light emitted by the products of high-energy neutrino interactions, and others are frozen into tanks on the surface to detect particles from atmospheric cosmic ray showers. IceCube is using the 10-in. diameter R7081-02 made by Hamamatsu Photonics. This paper describes the laboratory characterization and calibration of these PMTs before deployment. PMTs were illuminated with pulses ranging from single photons to saturation level. Parameterizations are given for the single photoelectron charge spectrum and the saturation behavior. Time resolution, late pulses and afterpulses are characterized. Because the PMTs are relatively large, the cathode sensitivity uniformity was measured. The absolute photon detection efficiency was calibrated using Rayleigh-scattered photons from a nitrogen laser. Measured characteristics are discussed in the context of their relevance to IceCube event reconstruction and simulation efforts. (C) 2010 Elsevier B.V. All rights reserved.
  •  
9.
  • Abbasi, R., et al. (författare)
  • The IceCube data acquisition system : Signal capture, digitization, and timestamping
  • 2009
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 601:3, s. 294-316
  • Tidskriftsartikel (refereegranskat)abstract
    • IceCube is a km-scale neutrino observatory under construction at the South Pole with sensors both in the deep ice (InIce) and on the surface (IceTop). The sensors, called Digital Optical Modules (DOMs). detect, digitize and timestamp the signals from optical Cherenkov-radiation photons. The DOM Main Board (MB) data acquisition subsystem is connected to the central DAQ in the IceCube Laboratory (ICL) by a single twisted copper wire-pair and transmits packetized data on demand. Time calibration is maintained throughout the array by regular transmission to the DOMs of precisely timed analog signals, synchronized to a central GPS-disciplined clock. The design goals and consequent features, functional capabilities, and initial performance of the DOM MB, and the operation of a combined array of DOMs as a system, are described here. Experience with the first InIce strings and the IceTop stations indicates that the system design and performance goals have been achieved. (c) 2009 Elsevier B.V. All rights reserved.
  •  
10.
  • Ageron, M., et al. (författare)
  • ANTARES : The first undersea neutrino telescope
  • 2011
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 656:1, s. 11-38
  • Tidskriftsartikel (refereegranskat)abstract
    • The ANTARES Neutrino Telescope was completed in May 2008 and is the first operational Neutrino Telescope in the Mediterranean Sea. The main purpose of the detector is to perform neutrino astronomy and the apparatus also offers facilities for marine and Earth sciences. This paper describes the design, the construction and the installation of the telescope in the deep sea, offshore from Toulon in France. An illustration of the detector performance is given. (C) 2011 Elsevier B.V. All rights reserved.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 27

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy