SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0168 9002 OR L773:1872 9576 ;lar1:(oru)"

Sökning: L773:0168 9002 OR L773:1872 9576 > Örebro universitet

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Billnert, Robert, 1981, et al. (författare)
  • New information on the characteristics of 1 in. x 1 in. cerium bromide scintillation detectors
  • 2011
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 647:1, s. 94-99
  • Tidskriftsartikel (refereegranskat)abstract
    • In view of highly demanded new and accurate data on prompt gamma-ray emission in nuclear fission a major part of investigations is directed towards the selection of suitable detector systems. Here we have studied a new type of crystal scintillation detectors made from cerium bromide (CeBr(3)). For the first time a full characterization of such a detector is presented in terms of energy resolution, pulse-height linearity, intrinsic activity and intrinsic timing resolution. In particular the latter one is very important for prompt fission gamma-ray studies, because the presence of fast neutrons, emitted in fission too, requires the time-of-flight method for their discrimination. The energy resolution has been found to be comparable to that of cerium-doped LaCl(3):Ce detectors at an efficiency comparable to the one of a LaBr(3):Ce detector of the same size. The intrinsic activity of the CeBr(3) crystal was observed to be much lower compared to lanthanum halide crystals. The intrinsic timing resolution of a coaxial 1 in. x 1 in. sized detector was measured relative to that of a previously characterized LaCl(3):Ce detector and found to be (326 +/- 7) Ps at (60)Co energies, which is in between those of a LaBr(3):Ce and a LaCl(3):Ce detector of same size.
  •  
2.
  • Göök, A., et al. (författare)
  • Application of the ShockleyRamo theorem on the grid inefficiency of Frisch grid ionization chambers
  • 2012
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 664:1, s. 289-293
  • Tidskriftsartikel (refereegranskat)abstract
    • The concept of grid inefficiency in Frisch grid ionization chambers and its influence on the anode pulse shape is explained in terms of the ShockleyRamo theorem for induced charges. The grid inefficiency correction is deduced from numerically calculated weighting potentials. A method to determine the correction factor experimentally is also presented. Experimental and calculated values of the correction factor are shown to be in good agreement. 
  •  
3.
  • Göök, A., et al. (författare)
  • Particle emission angle determination in Frisch grid ionization chambers by electron drift-time measurements
  • 2010
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 621:1-3, s. 401-405
  • Tidskriftsartikel (refereegranskat)abstract
    • The double kinetic energy measurement of fission fragments with a double-sided Frisch grid ionization chamber allows a careful determination of the emission angle, which is essential in order to apply appropriate energy-loss corrections. We present a drift-time method, which uses the time that free electrons need to drift from the location of their creation, e.g. by a fission fragment in the counting gas, to the grid, before inducing a signal on the anode. Such a measurement leaves energy and angular information fully decoupled. We demonstrate the applicability of the drift-time method for the example of the 234,238U (γ,f) reactions performed at the superconducting Darmstadt electron linear accelerator. The angular resolutions achieved with this method are comparable to those obtained with other methods.
  •  
4.
  • Oberstedt, Andreas, et al. (författare)
  • Energy degrader technique for light-charged particle spectroscopy at LOHENGRIN
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - Amsterdam : Elsevier. - 0168-9002 .- 1872-9576. ; 570:1, s. 51-54
  • Tidskriftsartikel (refereegranskat)abstract
    • The recoil mass-separator LOHENGRIN at Institute Laue-Langevin was originally designed for the spectrometry of binary fission fragments. Nevertheless, it was also used in the past for measuring light-charged particles from ternary fission. However, due to the electric field settings the energy distribution of the lightest particles was not completely accessible, which made the determination of mean kinetic energies, widths and, hence, emission yields difficult. In this paper we present an energy degrader technique that allows for the measurement of the entire energy spectrum of even the lightest ternary particles with LOHENGRIN.
  •  
5.
  • Oberstedt, Andreas, 1960-, et al. (författare)
  • Identification of prompt fission gamma-rays with lanthanum-chloride scintillation detectors
  • 2012
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 668, s. 14-20
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper we demonstrate the employment of LaCl3 : Ce scintillation detectors for the identification of prompt fission gamma-rays from gamma-radiation in contrast to other reactions. We present the properties of cylindrical 1.5 in. x 1.5 in. detectors in terms of intrinsic activity, energy resolution, intrinsic full peak efficiency and intrinsic timing resolution. In addition, we show results from the measurement of gamma-rays emitted in coincidence with the spontaneous fission of Cf-252, which lead us to the conclusion that the properties of the detectors used in this work, in particular the good timing resolution and a reasonably good energy resolution, are more than just sufficient for the assessment of prompt gamma-heat in future nuclear reactors as requested by the OECD. Hence, in our opinion, LaCl3 : Ce detectors, compared to those made out of LaBr3 : Ce crystals, represent an appropriate and quasi low-cost choice for the above mentioned applications.
  •  
6.
  • Oberstedt, Andreas, et al. (författare)
  • Neutron measurements with lanthanum-bromide scintillation detectors : a first approach
  • 2013
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 708, s. 7-14
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper we report on the measurement of gamma-rays using a 2 in. x 2 in. LaBr3:Ce scintillation detector. The gamma-rays were emitted in the spontaneous fission of Cf-252 and detected in coincidence with fission fragments. After presenting some of the properties of the detector, we show how well gamma-rays produced in different reactions may easily be distinguished by their characteristic time-of-flight. Then we focus on the analysis of gamma-rays from inelastically scattered neutrons in the scintillation crystal and demonstrate how this information may be used for neutron spectroscopy. We determine the neutron detection efficiency and compare it to the result of calculations based on existing reaction cross-sections. Finally, we discuss the detection performance in relation to other detector systems commonly used for neutron monitoring.
  •  
7.
  • Oberstedt, S., et al. (författare)
  • Artificial diamonds as radiation-hard detectors for ultra-fast fission-fragment timing
  • 2013
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 714, s. 31-37
  • Tidskriftsartikel (refereegranskat)abstract
    • In the framework of the construction of the double time-of-flight spectrometer VERDI, where we aim at measuring pre- and post-neutron masses directly and simultaneously, ultra-fast time pick-up detectors based on artificial diamond material were investigated for the first time with fission fragments from Cf-252 (0.5 MeV/u < E/A < 2 MeV/u). Signal stability under a high radiation fluence was determined up to at least 10(9) fission-fragments/cm(2) together with more than 3.5 x 10(9) neutrons/cm(2) and 3 x 10(10) alpha-particles/cm(2). This fluence is characteristic for fission experiments. The pre-requisite for the observed signal stability is the application of priming of the diamond material with a strong beta-source for about 48 h. The intrinsic timing resolution of a 100 mu m thick polycrystalline CVD diamond detector with a size of 1 x 1 cm(2) was determined to sigma(int) = (283 +/- 41) ps by comparison with Monte-Carlo simulations. Using broadband pre-amplifiers, 4-fold segmented detectors of same total size and with a thickness of 180 mu m show an intrinsic timing resolution of sigma(int) = (106 +/- 21) ps. This is highly competitive with the best micro-channel plate detectors. Due to the limited and batch-dependent charge collection efficiency of poly-crystalline diamond material, the detection efficiency for fission fragments may be smaller than 100%.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy