SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0360 3016 ;lar1:(uu)"

Sökning: L773:0360 3016 > Uppsala universitet

  • Resultat 1-10 av 39
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  • Johanson, J, et al. (författare)
  • In regard to Zurlo et al., IJROBP 2000;48:277-288
  • 2001
  • Ingår i: International journal of radiation oncology, biology, physics. - 0360-3016. ; 50, s. 279-
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
  •  
7.
  • Adjeiwaah, Mary, et al. (författare)
  • Quantifying the Effect of 3T Magnetic Resonance Imaging Residual System Distortions and Patient-Induced Susceptibility Distortions on Radiation Therapy Treatment Planning for Prostate Cancer
  • 2018
  • Ingår i: International Journal of Radiation Oncology, Biology, Physics. - : Elsevier. - 0360-3016 .- 1879-355X. ; 100:2, s. 317-324
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To investigate the effect of magnetic resonance system- and patient-induced susceptibility distortions from a 3T scanner on dose distributions for prostate cancers.Methods and Materials: Combined displacement fields from the residual system and patient-induced susceptibility distortions were used to distort 17 prostate patient CT images. VMAT dose plans were initially optimized on distorted CT images and the plan parameters transferred to the original patient CT images to calculate a new dose distribution.Results: Maximum residual mean distortions of 3.19 mm at a radial distance of 25 cm and maximum mean patient-induced susceptibility shifts of 5.8 mm were found using the lowest bandwidth of 122 Hz per pixel. There was a dose difference of <0.5% between distorted and undistorted treatment plans. The 90% confidence intervals of the mean difference between the dCT and CT treatment plans were all within an equivalence interval of (−0.5, 0.5) for all investigated plan quality measures.Conclusions: Patient-induced susceptibility distortions at high field strengths in closed bore magnetic resonance scanners are larger than residual system distortions after using vendor-supplied 3-dimensional correction for the delineated regions studied. However, errors in dose due to disturbed patient outline and shifts caused by patient-induced susceptibility effects are below 0.5%.
  •  
8.
  •  
9.
  • Bosco, Cecilia, et al. (författare)
  • Prostate Cancer Radiation Therapy and Risk of Thromboembolic Events
  • 2017
  • Ingår i: International Journal of Radiation Oncology, Biology, Physics. - : ELSEVIER SCIENCE INC. - 0360-3016 .- 1879-355X. ; 97:5, s. 1026-1031
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To investigate the risk of thromboembolic disease (TED) after radiation therapy (RT) with curative intent for prostate cancer (PCa).Patients and Methods: We identified all men who received RT as curative treatment (n=9410) and grouped according to external beam RT (EBRT) or brachytherapy (BT). By comparing with an age-and county-matched comparison cohort of PCa-free men (n = 46,826), we investigated risk of TED after RT using Cox proportional hazard regression models. The model was adjusted for tumor characteristics, demographics, comorbidities, PCa treatments, and known risk factors of TED, such as recent surgery and disease progression.Results: Between 2006 and 2013, 6232 men with PCa received EBRT, and 3178 underwent BT. A statistically significant association was found between EBRT and BT and risk of pulmonary embolism in the crude analysis. However, upon adjusting for known TED risk factors these associations disappeared. No significant associations were found between BT or EBRT and deep venous thrombosis.Conclusion: Curative RT for prostate cancer using contemporary methodologies was not associated with an increased risk of TED.
  •  
10.
  • Brændengen, Morten, et al. (författare)
  • Delineation of gross tumor volume (GTV) for radiation treatment planning of locally advanced rectal cancer using information from MRI or FDG-PET/CT : a prospective study
  • 2011
  • Ingår i: International Journal of Radiation Oncology, Biology, Physics. - : Elsevier BV. - 0360-3016 .- 1879-355X. ; 81:4, s. e439-e445
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE:Accurate delineation of target volumes is important to maximize radiation dose to the tumor and minimize it to nontumor tissue. Computed tomography (CT) and magnetic resonance imaging (MRI) are standard imaging modalities in rectal cancer. The aim was to explore whether functional imaging with F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET), combined with CT (FDG-PET/CT) gives additional information to standard pretreatment evaluation and changes the shape and size of the gross tumor volume (GTV).METHODS AND MATERIALS:From 2007 to 2009, 77 consecutive patients with locally advanced rectal cancer were prospectively screened for inclusion in the study at two university hospitals in Sweden, and 68 patients were eligible. Standard GTV was delineated using information from clinical examination, CT, and MRI (GTV-MRI). Thereafter, a GTV-PET was defined in the fused PET-CT, and the target volume delineations were compared for total volume, overlap, and mismatch. Pathologic uptake suspect of metastases was also registered.RESULTS:The median volume of GTV-MRI was larger than that of GTV-PET: 111 cm3 vs. 87 cm3 (p < 0.001). In many cases, the GTV-MRI contained the GTV defined on the PET/CT images as subvolumes, but when a GTV total was calculated after the addition of GTV-PET to GTV-MRI, the volume increased, with median 11% (range, 0.5–72%). New lesions were seen in 15% of the patients for whom PET/CT was used.CONCLUSIONS:FDG-PET/CT facilitates and adds important information to the standard delineation procedure of locally advanced rectal cancer, mostly resulting in a smaller GTV, but a larger total GTV using the union of GTV-MRI and GTV-PET. New lesions were sometimes seen, potentially changing the treatment strategy.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 39
Typ av publikation
tidskriftsartikel (38)
forskningsöversikt (1)
Typ av innehåll
refereegranskat (32)
övrigt vetenskapligt/konstnärligt (7)
Författare/redaktör
Glimelius, Bengt (10)
Dasu, Alexandru (7)
Toma-Daşu, Iuliana (4)
Glimelius, B (3)
Nilsson, Per (3)
Nilsson, Kristina, 1 ... (3)
visa fler...
Goldstein, D (3)
Huguet, F (3)
Nilsson, Per J. (2)
Holmberg, Lars (2)
Nyholm, Tufve (2)
Widmark, Anders (2)
Nilsson, Kristina (2)
Alcorn, Sara (2)
Rao, Avani D. (2)
Ladra, Matthew M. (2)
Villar, Rosangela C. (2)
Chen, Michael J. (2)
Kobyzeva, Daria (2)
Dieckmann, Karin (2)
Terezakis, Stephanie ... (2)
Ford, Eric C. (2)
MacDonald, Shannon M ... (2)
Nechesnyuk, Alexey (2)
Winey, Brian A. (2)
Dieckmann, K. (2)
MacDonald, S. (2)
Nechesnyuk, A. (2)
Winey, B. (2)
Terezakis, S. A. (2)
Carlsson, J (2)
Hartman, T (2)
Blomqvist, Lennart (2)
Lundqvist, H (2)
Turesson, Ingela (2)
Van Houtte, Paul (2)
Goldstein, David (2)
Pahlman, L (2)
Gunnlaugsson, Adalst ... (2)
Gubanski, M (2)
Spry, N (2)
Van Laethem, Jean Lu ... (2)
Hammel, Pascal (2)
Bonnetain, F (2)
Brændengen, Morten (2)
Kortmann, Rolf-Diete ... (2)
Chen, Qinyu (2)
Denekamp, Juliana (2)
Vernerey, Dewi (2)
Huguet, Florence (2)
visa färre...
Lärosäte
Karolinska Institutet (17)
Umeå universitet (6)
Linköpings universitet (5)
Lunds universitet (5)
Stockholms universitet (4)
visa fler...
Örebro universitet (1)
visa färre...
Språk
Engelska (39)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (23)
Samhällsvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy