1.
  • Alagic, Z., et al. (författare)
  • Ultra-low-dose CT for extremities in an acute setting : initial experience with 203 subjects
  • 2020
  • Ingår i: Skeletal Radiology. - : Springer Nature. - 0364-2348 .- 1432-2161. ; 49:4, s. 531-539
  • Tidskriftsartikel (refereegranskat)abstract
    • ObjectiveThe purpose of this study was to assess if ultra-low-dose CT is a useful clinical alternative to digital radiographs in the evaluation of acute wrist and ankle fractures.Materials and methodsAn ultra-low-dose protocol was designed on a 256-slice multi-detector CT. Patients from the emergency department were evaluated prospectively. After initial digital radiographs, an ultra-low-dose CT was performed. Two readers independently analyzed the images. Also, the radiation dose, examination time, and time to preliminary report was compared between digital radiographs and CT.ResultsIn 207 extremities, digital radiography and ultra-low-dose CT detected 73 and 109 fractures, respectively (p < 0.001). The odds ratio for fracture detection with ultra-low-dose CT vs. digital radiography was 2.0 (95% CI, 1.4–3.0). CT detected additional fracture-related findings in 33 cases (15.9%) and confirmed or ruled out suspected fractures in 19 cases (9.2%). The mean effective dose was comparable between ultra-low-dose CT and digital radiography (0.59 ± 0.33 μSv, 95% CI 0.47–0.59 vs. 0.53 ± 0.43 μSv, 95% CI 0.54–0.64). The mean combined examination time plus time to preliminary report was shorter for ultra-low-dose CT compared to digital radiography (7.6 ± 2.5 min, 95% CI 7.1–8.1 vs. 9.8 ± 4.7 min, 95% CI 8.8–10.7) (p = 0.002). The recommended treatment changed in 34 (16.4%) extremities.ConclusionsUltra-low-dose CT is a useful alternative to digital radiography for imaging the peripheral skeleton in the acute setting as it detects significantly more fractures and provides additional clinically important information, at a comparable radiation dose. It also provides faster combined examination and reporting times.
  •  
2.
  • Edlund, R, et al. (författare)
  • Cone-Beam CT in diagnosis of scaphoid fractures
  • 2016
  • Ingår i: Skeletal radiology. - : Springer Science and Business Media LLC. - 1432-2161 .- 0364-2348. ; 45:2, s. 197-204
  • Tidskriftsartikel (refereegranskat)
  •  
3.
  •  
4.
  • Gärdin, Anna, et al. (författare)
  • The long-term clinical and MRI results following eccentric calf muscle training in chronic Achilles tendinosis
  • 2010
  • Ingår i: Skeletal Radiology. - : Springer Science and Business Media LLC. - 0364-2348 .- 1432-2161. ; 39:5, s. 435-442
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To evaluate the long-term results following eccentric calf-muscle training in patients with chronic Achilles tendinopathy.MATERIALS AND METHODS: A total of 24 patients with chronic Achilles tendinopathy were included in a study evaluating MRI findings and clinical symptoms before and after 3 months of daily eccentric calf-muscle strength training. Median duration of symptoms was 18 months (range 6-120). Four of the patients did not perform the prescribed treatment for different reasons and were followed for 14 months. The resulting 20 treated patients completed 4.2-year (range 29-58 months) follow up. Tendon volume was evaluated by using 3D seed growing technique and signal abnormalities were visually semi-quantitatively graded. Level of pain and performance was categorized using a questionnaire completed by the patient.RESULTS: In the symptomatic treated patients, median intensity level of pain decreased from moderate/severe at time of inclusion to mild at follow up (p < 0.05). Median level of performance increased from severe impairment at time of inclusion to normal at follow up (p < 0.05). 12 out of 20 patients had raised intratendinous signal at time of inclusion compared to 2 out of 20 patients at follow up (p < 0.001). Mean tendon-volume measured 6.7 cm(3) (SD 2.0) at time of inclusion and 6.4 cm(3) (SD 2.0) at follow up (p = 0.18). The four symptomatic non-treated tendons did not improve regarding pain, performance, intratendinous signal or tendon volume.CONCLUSION: We found decreased pain, improved performance and decreased intratendinous signal both compared to index examination and immediately after the 3 months training regimen in a 4.2-year clinical and MRI follow up, in a group of patients treated with heavy loaded eccentric calf-muscle training for chronic Achilles tendinopathy. The improvements were greater at 4.2-year follow up, despite no further active treatment, than immediately after the treatment. This may indicate a good long-term prognosis for Achilles tendinosis patients.
  •  
5.
  •  
6.
  • Kjellberg, Martin, et al. (författare)
  • Measurement of leg length discrepancy after total hip arthroplasty : the reliability of a plain radiographic method compared to CT-scanogram
  • 2012
  • Ingår i: Skeletal Radiology. - : Springer London. - 0364-2348 .- 1432-2161. ; 41:2, s. 187-191
  • Tidskriftsartikel (refereegranskat)abstract
    • To measure the interobserver reliability and intraobserver reproducibility of post total hip arthroplasty (THA) leg length discrepancy (LLD) measurement on radiographs as well as to evaluate its accuracy by comparing it with LLD measurement on computed tomographic scanogram (CT-scanogram). In this prospective study, postoperative LLD measurements in ten THA patients were made by four observers on anteroposterior radiographs of the pelvis (inter-teardrop line to the tip of lesser trochanter) and compared to LLD measurements made on CT-scanogram scout views of the lower limb. Two observers repeated the LLD measurements on radiographs 8 weeks after the first measurements. The interobserver reliability of the LLD measurement on plain radiographs was evaluated by comparing the measurements of the four observers and the intraobserver reproducibility by comparing the two repeated measurements made by the two observers. We found excellent interobserver reliability (mean ICC 0.83) and intraobserver reproducibility (ICC 0.90 and 0.88) of the LLD measurements on plain radiographs. There was a moderate to excellent agreement, but with wide variation of measurements among the four observers, when plain radiographic measurement was compared with CT-scanogram (ICC 0.58, 0.60, 0.71, and 0.82). Despite the excellent interobserver reliability and intraobserver reproducibility of LLD measurement on radiographs, clinicians should be aware of its limited accuracy when compared to CT-scanogram.
  •  
7.
  • Klintström, Eva, et al. (författare)
  • Trabecular bone structure parameters from 3D image processing of clinical multi-slice and cone-beam computed tomography data
  • 2014
  • Ingår i: Skeletal Radiology. - : Springer. - 0364-2348 .- 1432-2161. ; 43:2, s. 197-204
  • Tidskriftsartikel (refereegranskat)abstract
    • ObjectiveBone strength depends on both mineral content and bone structure. The aim of this in vitro study was to develop a method of quantitatively assessing trabecular bone structure by applying three-dimensional image processing to data acquired with multi-slice and cone-beam computed tomography using micro-computed tomography as a reference.Materials and MethodsFifteen bone samples from the radius were examined. After segmentation, quantitative measures of bone volume, trabecular thickness, trabecular separation, trabecular number, trabecular nodes, and trabecular termini were obtained.ResultsThe clinical machines overestimated bone volume and trabecular thickness and underestimated trabecular nodes and number, but cone-beam CT to a lesser extent. Parameters obtained from cone beam CT were strongly correlated with μCT, with correlation coefficients between 0.93 and 0.98 for all parameters except trabecular termini.ConclusionsThe high correlation between cone-beam CT and micro-CT suggest the possibility of quantifying and monitoring changes of trabecular bone microarchitecture in vivo using cone beam CT.
  •  
8.
  • Mahmood, Sarwar S, 1975-, et al. (författare)
  • Validity, reliability and reproducibility of plain radiographic measurements after total hip arthroplasty
  • 2015
  • Ingår i: Skeletal Radiology. - : Springer. - 0364-2348 .- 1432-2161. ; 44:3, s. 345-351
  • Tidskriftsartikel (refereegranskat)abstract
    • In total hip arthroplasty (THA), radiographic preoperative planning and postoperative evaluation of acetabular component, femoral offset (FO) and leg length discrepancy (LLD) require good validity, interobserver reliability and intraobserver reproducibility. In this study, we evaluated the validity of the Sundsvall method of FO measurement and the interobserver reliability and intraobserver reproducibility of measurement of FO, LLD, acetabular cup inclination and anteversion. Ninety patients with primary unilateral osteoarthritis (OA) were included in this prospective study. On postoperative radiographs FO by the Sundsvall method (femoral axis-pelvic midline), FO by a standard method (femoral axis-hip rotational centre-teardrop point), LLD (inter-teardrop line-lesser trochanter), acetabular cup inclination (on AP view the angle between the cup rim and transischial line) and anteversion (on lateral view the angle between the face of acetabulum and a line perpendicular to the horizontal plane) were measured. The interobserver reliability and intraobserver reproducibility were calculated for three independent observers. The concurrent validity and degree of prediction of the Sundsvall method are measured by comparing its results with the standard method. The interobserver reliability of all measurements was excellent (ICC > 0.80), except for LLD, which was substantial (ICC = 0.79). The intraobserver reproducibility of all measurements was excellent (ICC > 0.80). The concurrent validity of the Sundsvall method compared to the standard method was good with a positive correlation. The Sundsvall method is as reliable as the standard method. The evaluated radiographic measurement methods have the required validity and reliability to be used in clinical practice.
  •  
9.
  •  
10.
  •  