1.
  • Abat, Ferran, et al. (författare)
  • Ultrasound-guided versus blind interventions in patellar tendon lesions : a cadaveric study
  • 2021
  • Ingår i: Skeletal Radiology. - : Springer. - 0364-2348 .- 1432-2161. ; 50:5, s. 967-972
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The present study aims to analyze the accuracy of injections aimed to hit the proximal and depth part of the patellar tendon "target point" in patellar tendinopathy, comparing ultrasound-guided or non-ultrasound-guided (blind) injections.Methods: A cadaver randomized study was carried out. Injections were performed under ultrasound control, as well as blinded. There were 26 knees from fresh cadavers and injections were placed by 26 practitioners with experience in the use of musculoskeletal ultrasound and injection treatment. Each participant performed 6 ultrasound-guided and 6 blind punctures in different cadaveric specimens. This provided 312 injections that were analyzed in 2 different anatomical cuts, thus providing a database of 624 measurements for statistical analysis.Results: Statistically significant differences were observed (p < 0.0001) in the distance from the target point between the ultrasound-guided and the non-guided infiltrations. The "unguided" injections were considered to have been performed on average 10 mm away from the target point compared to the "ultrasound-guided" injections. The ultrasound-guided injections obtained an accuracy of 74.36% while the "non-ultrasound-guided" injections obtained an accuracy of 11.54% (p < 0.0001).Conclusion: The use of ultrasound to guide the positioning of injections on the dorsal side of the proximal patellar tendon had a significantly higher accuracy compared to blind injections. The finding provides knowledge of importance for injection treatment.
  •  
2.
  • Kjellberg, Martin, et al. (författare)
  • Measurement of leg length discrepancy after total hip arthroplasty : the reliability of a plain radiographic method compared to CT-scanogram
  • 2012
  • Ingår i: Skeletal Radiology. - : Springer London. - 0364-2348 .- 1432-2161. ; 41:2, s. 187-191
  • Tidskriftsartikel (refereegranskat)abstract
    • To measure the interobserver reliability and intraobserver reproducibility of post total hip arthroplasty (THA) leg length discrepancy (LLD) measurement on radiographs as well as to evaluate its accuracy by comparing it with LLD measurement on computed tomographic scanogram (CT-scanogram). In this prospective study, postoperative LLD measurements in ten THA patients were made by four observers on anteroposterior radiographs of the pelvis (inter-teardrop line to the tip of lesser trochanter) and compared to LLD measurements made on CT-scanogram scout views of the lower limb. Two observers repeated the LLD measurements on radiographs 8 weeks after the first measurements. The interobserver reliability of the LLD measurement on plain radiographs was evaluated by comparing the measurements of the four observers and the intraobserver reproducibility by comparing the two repeated measurements made by the two observers. We found excellent interobserver reliability (mean ICC 0.83) and intraobserver reproducibility (ICC 0.90 and 0.88) of the LLD measurements on plain radiographs. There was a moderate to excellent agreement, but with wide variation of measurements among the four observers, when plain radiographic measurement was compared with CT-scanogram (ICC 0.58, 0.60, 0.71, and 0.82). Despite the excellent interobserver reliability and intraobserver reproducibility of LLD measurement on radiographs, clinicians should be aware of its limited accuracy when compared to CT-scanogram.
  •  
3.
  • Mahmood, Sarwar S, 1975-, et al. (författare)
  • Validity, reliability and reproducibility of plain radiographic measurements after total hip arthroplasty
  • 2015
  • Ingår i: Skeletal Radiology. - : Springer. - 0364-2348 .- 1432-2161. ; 44:3, s. 345-351
  • Tidskriftsartikel (refereegranskat)abstract
    • In total hip arthroplasty (THA), radiographic preoperative planning and postoperative evaluation of acetabular component, femoral offset (FO) and leg length discrepancy (LLD) require good validity, interobserver reliability and intraobserver reproducibility. In this study, we evaluated the validity of the Sundsvall method of FO measurement and the interobserver reliability and intraobserver reproducibility of measurement of FO, LLD, acetabular cup inclination and anteversion. Ninety patients with primary unilateral osteoarthritis (OA) were included in this prospective study. On postoperative radiographs FO by the Sundsvall method (femoral axis-pelvic midline), FO by a standard method (femoral axis-hip rotational centre-teardrop point), LLD (inter-teardrop line-lesser trochanter), acetabular cup inclination (on AP view the angle between the cup rim and transischial line) and anteversion (on lateral view the angle between the face of acetabulum and a line perpendicular to the horizontal plane) were measured. The interobserver reliability and intraobserver reproducibility were calculated for three independent observers. The concurrent validity and degree of prediction of the Sundsvall method are measured by comparing its results with the standard method. The interobserver reliability of all measurements was excellent (ICC > 0.80), except for LLD, which was substantial (ICC = 0.79). The intraobserver reproducibility of all measurements was excellent (ICC > 0.80). The concurrent validity of the Sundsvall method compared to the standard method was good with a positive correlation. The Sundsvall method is as reliable as the standard method. The evaluated radiographic measurement methods have the required validity and reliability to be used in clinical practice.
  •  