SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0364 2348 OR L773:1432 2161
 

Sökning: L773:0364 2348 OR L773:1432 2161 > Lydersen Stian > Long-term in-vitro ...

Long-term in-vitro precision of direct digital X-ray radiogrammetry

Dhainaut, Alvilde (författare)
Hoff, Mari (författare)
Kalvesten, Johan (författare)
visa fler...
Lydersen, Stian (författare)
Forslind, Kristina (författare)
Lund University,Lunds universitet,Kliniska Vetenskaper, Helsingborg,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Sciences, Helsingborg,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
Haugeberg, Glenn (författare)
visa färre...
 (creator_code:org_t)
2011-05-11
2011
Engelska.
Ingår i: Skeletal Radiology. - : Springer Science and Business Media LLC. - 1432-2161 .- 0364-2348. ; 40:12, s. 1575-1579
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Digital X-ray radiogrammetry (DXR) calculates peripheral bone mineral density (BMD) from hand radiographs. The short-term precision for direct DXR has been reported to be highly satisfactory. However, long-term precision for this method has not been examined. Thus, the aim of this study was to examine the long-term in-vitro precision for the new direct digital version of DXR. The in-vitro precision for direct DXR was tested with cadaver phantoms on four different X-ray systems at baseline, 3 months, 6 months, and in one machine also at 12 months. At each time point, 31 measurements were performed. The in-vitro longitudinal precision for the four radiographic systems ranged from 0.22 to 0.43% expressed as coefficient of variation (CV%). The smallest detectable difference (SDD) ranged from 0.0034 to 0.0054 g/cm(2). The in vitro long-term precision for direct DXR was comparable to the previous reported short-term in-vitro precision for all tested X-ray systems. These data show that DXR is a stable method for detecting small changes in bone density during 6-12 months of follow-up.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Digital X-ray radiogrammetry
Precision
Rheumatoid arthritis
Osteoporosis
Bone mineral density

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy