SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0390 6078 OR L773:1592 8721 ;pers:(Stilgenbauer S.)"

Sökning: L773:0390 6078 OR L773:1592 8721 > Stilgenbauer S.

  • Resultat 1-10 av 14
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  • Jaramillo, S, et al. (författare)
  • Prognostic impact of prevalent chronic lymphocytic leukemia stereotyped subsets: analysis within prospective clinical trials of the German CLL Study Group (GCLLSG)
  • 2020
  • Ingår i: Haematologica. - : Ferrata Storti Foundation (Haematologica). - 1592-8721 .- 0390-6078. ; 105:11, s. 2598-2607
  • Tidskriftsartikel (refereegranskat)abstract
    • Almost one-third of all patients with chronic lymphocytic leukemia (CLL) express stereotyped B cell receptor immunoglobulins (BcR IG) and can be assigned to distinct subsets, each with a particular BcR IG. The largest stereotyped subsets are #1, #2, #4 and #8, associated with specific clinicobiological characteristics and outcomes in retrospective studies. We assessed the associations and prognostic value of these BcR IG in prospective multicenter clinical trials reflective of two different clinical situations: i) early-stage patients (watch-and-wait arm of the CLL1 trial) (n=592); ii) patients in need of treatment, enrolled in 3 phase III trials (CLL8, CLL10, CLL11), treated with different chemo-immunotherapies (n=1861). Subset #1 was associated with del(11q), higher CLL international prognostic index (CLL-IPI) scores and similar clinical course to CLL with unmutated immunoglobulin heavy variable (IGHV) genes (U-CLL) in both early and advanced stage groups. IGHV-mutated (M-CLL) subset #2 cases had shorter time-to-first-treatment (TTFT) versus other M-CLL cases in the early-stage cohort (HR: 4.2, CI: 2-8.6, p<0.001), and shorter time-to-next-treatment (TTNT) in the advanced-stage cohort (HR: 2, CI: 1.2-3.3, p=0.005). M-CLL subset #4 was associated with lower CLL-IPI scores and younger age at diagnosis; in both cohorts, these patients showed a trend towards better outcomes versus other M-CLL. U-CLL subset #8 was associated with trisomy 12. Overall, this study shows that major stereotyped subsets have distinctive characteristics. For the first time in prospective multicenter clinical trials, subset # 2 appeared as an independent prognostic factor for earlier TTFT and TTNT and should be proposed for risk stratification of patients.
  •  
6.
  •  
7.
  •  
8.
  •  
9.
  • Sutton, LA, et al. (författare)
  • Comparative analysis of targeted next-generation sequencing panels for the detection of gene mutations in chronic lymphocytic leukemia: an ERIC multi-center study
  • 2021
  • Ingår i: Haematologica. - : Ferrata Storti Foundation (Haematologica). - 1592-8721 .- 0390-6078. ; 106:3, s. 682-691
  • Tidskriftsartikel (refereegranskat)abstract
    • Next-generation sequencing (NGS) has transitioned from research to clinical routine, yet the comparability of different technologies for mutation profiling remains an open question. We performed a European multicenter (n=6) evaluation of three amplicon-based NGS assays targeting 11 genes recurrently mutated in chronic lymphocytic leukemia. Each assay was assessed by two centers using 48 pre-characterized chronic lymphocytic leukemia samples; libraries were sequenced on the Illumina MiSeq instrument and bioinformatics analyses were centralized. Across all centers the median percentage of target reads ≥100x ranged from 94.2-99.8%. To rule out assay-specific technical variability, we first assessed variant calling at the individual assay level i.e. pairwise analysis of variants detected amongst partner centers. After filtering for variants present in the paired normal sample and removal of PCR/sequencing artefacts, the panels achieved 96.2% (Multiplicom), 97.7% (TruSeq) and 90% (HaloPlex) concordance at a VAF >0.5%. Reproducibility was assessed by looking at the inter-laboratory variation in detecting mutations and 107/115 (93% concordance) of mutations were detected by all 6 centers, while the remaining 8/115 (7%) variants were undetected by a single center and 6/8 of these variants concerned minor subclonal mutations (VAF <5%). We sought to investigate low-frequency mutations further by using a high-sensitivity assay containing unique molecular identifiers, which confirmed the presence of several minor subclonal mutations. Thus, while amplicon-based approaches can be adopted for somatic mutation detection with VAFs >5%, after rigorous validation, the use of unique molecular identifiers may be necessary to reach a higher sensitivity and ensure consistent and accurate detection of low-frequency variants.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 14

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy