SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0882 2786 ;pers:(De Bruyn Hugo)"

Sökning: L773:0882 2786 > De Bruyn Hugo

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Braian, Michael, et al. (författare)
  • Tolerance Measurements on Internal- and External-Hexagon Implants
  • 2014
  • Ingår i: International Journal of Oral & Maxillofacial Implants. - : Quintessence. - 0882-2786 .- 1942-4434. ; 29:4, s. 846-852
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To measure the horizontal machining tolerances of the interface between internal-and external-hexagon implants and analogs with corresponding components after delivery from the manufacturer. These values may be a valuable tool for evaluating increasing misfit caused by fabrication, processing, and wear. Materials and Methods: Seven implants and seven analogs with external-and internal-hexagon connections (Biomet 3i) with corresponding prefabricated gold cylinders and gold screws, prefabricated cylindric plastic cylinders, and laboratory screws were studied. One set of components from the external and internal groups was measured manually and digitally. Measurements from the test subjects were compared with identical measurements from the virtual model to obtain threshold values. The virtual model was then used to obtain optimally oriented cuts. Results: The horizontal machining tolerances for castable plastic abutments on external implants were 12 +/- 89 mu m, and for internal implants they were 86 +/- 47 mu m. Tolerance measurements on prefabricated gold abutments for external implants were 44 +/- 9 mu m, and for internal implants they were 58 +/- 28 mu m. Conclusion: The groups with metallic components showed the smallest tolerance at < 50 mu m for the external group and < 90 mu m for the internal group. The prefabricated plastic cylinder groups ranged from < 100 mu m for external and < 130 mu m for internal connection.
  •  
2.
  • Cooper, Lyndon F., et al. (författare)
  • Immediate Provisionalization of Dental Implants Placed in Healed Alveolar Ridges and Extraction Sockets : A 5-year Prospective Evaluation
  • 2014
  • Ingår i: International Journal of Oral & Maxillofacial Implants. - : Quintessence. - 0882-2786 .- 1942-4434. ; 29:3, s. 709-717
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: This 5-year prospective multicenter study compared implant survival and success, peri-implant health and soft tissue responses, crestal bone level stability, and complication rates following immediate loading of single OsseoSpeed implants placed in anterior maxillary healed ridges or extraction sockets. Materials and Methods: Individuals requiring anterior tooth replacement with single implants were treated and immediately provisionalized. Definitive all-ceramic crowns were placed at 12 weeks. Implant survival, bone levels, soft tissue levels, and peri-implant health were monitored for 5 years. Results: One hundred thirteen patients received implants in fresh sockets (55) and healed ridges (58). After 5 years, 45 and 49 patients remained for evaluation, respectively. During the first year, three implants failed in the extraction socket group (94.6% survival) and one implant failed in the healed ridge group (98.3% survival); this difference was not significant. No further implant failures were recorded. After 5 years, the interproximal crestal bone levels were located a mean of 0.43 +/- 0.63 mm and 0.38 +/- 0.62 mm from the reference points of implants in sockets and healed ridges (not a significant difference). In both groups, papillae increased over time and peri-implant mucosal zenith positions were stable from the time of definitive crown placement in sockets and healed ridges. Compared to flap surgery for implants in healed ridges, flapless surgery resulted in increased peri-implant mucosal tissue dimension (average, 0.78 +/- 1.34 mm vs 0.19 +/- 0.79 mm). Conclusion: After 5 years, the bone and soft tissue parameters that characterize implant success and contribute to dental implant esthetics were similar following the immediate provisionalization of implants in sockets and healed ridges. The overall tissue responses and reported implant survival support the immediate provisionalization of dental implants in situations involving healed ridges and, under ideal circumstances, extraction sockets.
  •  
3.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy