SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0882 2786 ;pers:(Friberg Bertil 1950)"

Sökning: L773:0882 2786 > Friberg Bertil 1950

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Friberg, Bertil, 1950, et al. (författare)
  • A new self-tapping Brånemark implant: clinical and radiographic evaluation.
  • 1992
  • Ingår i: The International journal of oral & maxillofacial implants. - 0882-2786. ; 7:1, s. 80-5
  • Tidskriftsartikel (refereegranskat)abstract
    • A new self-tapping Brånemark implant designed for denser bone qualities was evaluated with regard to insertion technique, complications, marginal bone remodeling, and survival rate. Thirty patients, representing 21 mandibles and 9 maxillae, participated in the study. In each patient both standard and self-tapping implants were placed, and a total of 179 implants, 88 self-tapping and 91 standard, were inserted. Thirteen of 62 mandibular self-tapping implants reached their correct positions only after using the screw tap or the cylinder wrench for manual insertion. No such problems were noted when using standard fixtures after bone pre-tapping. In the maxillae, neither of the two implant designs presented any problems. One standard and one self-tapping fixture failed to osseointegrate. Radiolucencies were seen in the bone around the apical portion of two fixtures, one of each design. The mean marginal bone resorption after 1 year of follow-up was 0.5 to 0.6 mm for the two fixture types.
  •  
2.
  • Friberg, Bertil, 1950, et al. (författare)
  • Clinical outcome of Brånemark System implants of various diameters: a retrospective study.
  • 2002
  • Ingår i: The International journal of oral & maxillofacial implants. - 0882-2786. ; 17:5, s. 671-7
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: The purpose of this study was to evaluate the outcome of the 3 different diameters of Brånemark System implants, with special focus on the 5.0-mm-diameter implant. MATERIALS AND METHODS: Ninety-eight patients (99 jaws) with a mean age of 62 years were included in this retrospective report. The mean follow-up period was 2 years and 8 months. A total of 379 Brånemark System implants (3.75 mm diameter, n = 146; 4.0 mm diameter, n = 76; 5.0 mm diameter, n = 157) were placed in 29 edentulous and 70 partially edentulous jaws. RESULTS: Eight of the 146 implants in the 3.75-mm-diameter group failed (5.5%). The corresponding figures for the 4.0- and 5.0-mm-diameter implants were 3 of 76 (3.9%) and 7 of 157 (4.5%), respectively. DISCUSSION: All failures were recorded in maxillae, ie, 18 of the 298 placed, and the majority of these were found in bone quantity group B and quality group 2. Only 3 implants of 131 failed in bone judged as quality 4. The marginal bone loss was low for the 3 implant diameter groups. CONCLUSION: The favorable outcome in bone of poor quality is ascribed partly to the use of an adapted preparation technique and extended healing periods for achievement of the best primary and secondary implant stability possible.
  •  
3.
  • Friberg, Bertil, 1950, et al. (författare)
  • Early failures in 4,641 consecutively placed Brånemark dental implants: a study from stage 1 surgery to the connection of completed prostheses.
  • 1991
  • Ingår i: The International journal of oral & maxillofacial implants. - 0882-2786. ; 6:2, s. 142-6
  • Tidskriftsartikel (refereegranskat)abstract
    • This study comprised 4,641 Brånemark dental implants, which were retrospectively followed from stage 1 surgery to completion of the prosthetic restorations. The implants were placed during a 3-year period (1986 to 1988) in 943 jaws, representing 889 patients with complete and partial edentulism. The jaw and sex distribution revealed a predominance of mandibles (564/943) and females (534/943). The mean age of the patients was 57.5 years (range 13 to 88 years) at implant placement. Only 69 (1.5%) fixtures failed to integrate, and most losses were seen in completely edentulous maxillae (46/69), in which the jaw bone exhibited soft quality and severe resorption. A preponderance of failures could also be seen among the shortest fixtures (7 mm). A majority of the mobile implants were recorded at the abutment connection (stage 2) operation (48/69).
  •  
4.
  • Olsson, M, et al. (författare)
  • MkII--a modified self-tapping Brånemark implant: 3-year results of a controlled prospective pilot study.
  • 1995
  • Ingår i: The International journal of oral & maxillofacial implants. - 0882-2786. ; 10:1, s. 15-21
  • Tidskriftsartikel (refereegranskat)abstract
    • A modified self-tapping implant (MkII) with improved cutting characteristics has been designed for use in both maxillae and mandibles. Four sequential studies were conducted to evaluate the outcome of the MkII implant compared to the standard implant. The results presented here are from the extended pilot study that has been conducted as an intra-individual study of 103 patients; ie, each patient received both test (MkII) and control (standard Brånemark System) implants. Seventy patients were treated in the mandible and 33 in the maxilla. The cumulative survival rates and marginal bone resorption showed equivalent results for both test and control implants. Three-year cumulative survival rates were 87.9% and 86.8% for test and control implants in maxilla, respectively, and 99.5% and 100% in mandibles, respectively. The mean marginal bone resorption was approximately 0.5 (control) to (MK II) 0.6 mm after 3 years of function. A total of 288 test implants and 275 control implants were placed. All implants, both test and control, could be placed in an appropriate implant position, but 21.2% of the implants were not fully seated by machine power only; the use of a manual cylinder wrench for the final turns was necessary. During the last phase of the study, however, with an increase in twist-drill diameter from 3.0 to 3.15 mm and an increased motor torque, the prerequisites of successful implant placement into final position were met.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy