SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1078 5884 OR L773:1532 2165 ;pers:(Ivancev Krassi)"

Sökning: L773:1078 5884 OR L773:1532 2165 > Ivancev Krassi

  • Resultat 1-10 av 30
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Alhadad, Alaa, et al. (författare)
  • Percutaneous transluminal renal angioplasty (PTRA) and surgical revascularisation in renovascular disease - A retrospective comparison of results, complications, and mortality
  • 2004
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; 27:2, s. 151-156
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective. To evaluate results, complications and mortality following percutaneous transluminal renal angioplasty (PTRA) and open surgical revascularisation for renovascular disease. Methods. A retrospective evaluation of 381 renovascular patients (median age 64, range 9-99 years, 152 women) treated at Malmo University Hospital during 1987-1996. Two hundred and sixty-two (69%) of the patients were treated with PTRA, 106 (28%) with open revascularisation. Results. Thirty-day mortality was 2% in the PTRA group and 9% after open surgery (p < 0.001). There were no differences between groups concerning the number of re-do procedures, but first re-do was performed after seven (IQR 3-14) months in the PTRA group, and after 15 (IQR 10-44) months after open revascularisation (p < 0.0001). After a median follow-up of 4 months (IQR 0-13) systolic and diastolic blood pressure (BP) had decreased (p < 0.0001) in both groups. The number of antihypertensive drugs was reduced (p < 0.0001) and S-creatinine levels were unchanged in both groups. Longtime survival assessed with log-rank analysis was better (p < 0.01) in the PTRA group. The risk ratio for death with open revascularisation was 1.69 (p < 0.01). Conclusions. In this retrospective comparison, PTRA was as effective as open revascularisation, with lower complication rate and lower early and long-time mortality, but with shorter time to first re-do.
  •  
2.
  • Björses, Katarina, et al. (författare)
  • Kissingstents in the Aortic Bifurcation - a Valid Reconstruction for Aorto-iliac Occlusive Disease.
  • 2008
  • Ingår i: European journal of vascular and endovascular surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; Aug 7, s. 424-431
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To evaluate outcome and patency predicting factors of kissingstent treatment for aorto iliac occlusive disease (AIOD). METHODS: Patients treated with kissingstents for AOID between 1995 and 2004 at a tertiary referral center were identified through local databases. Chart review and preoperative images were used for TASC and Fontaine classification. Follow-up consisted of clinical exams, ABI and/or duplex. Patency rates were estimated by Kaplan-Meier analysis, and Cox multivariate regression was used to determine factors associated with patency. RESULTS: 173 consecutive patients (46% male, mean 64 years) were identified. TASC distribution was: A 15%, B 34%, C 10%, D 41%. Mean follow-up was 36 months (range: 1-144). 30-day mortality was 1% (2 patients), and 1-year survival was 91% (157 patients). 2 patients underwent late, open conversion and 13 patients suffered minor puncture site complications. Primary, assisted primary and secondary patency was: 97%, 99% and 100%, and 83%, 90% and 95% at twelve and 36 months respectively. There was no significant difference in patency between the TASC groups. Patency was significantly worse for patients in Fontaine class III. CONCLUSIONS: Aortoiliac kissing stents is a valid alternative to open repair for TASC A-D lesions. The procedure has low mortality and morbidity and good patency at 3 years.
  •  
3.
  • Dias, Nuno, et al. (författare)
  • Commentary: "Aneurysm Sac Pressure after EVAR"
  • 2007
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; 34:4, s. 41-432
  • Tidskriftsartikel (refereegranskat)abstract
    • Abstract is not available
  •  
4.
  •  
5.
  • Dias, Nuno, et al. (författare)
  • EVAR of Aortoiliac Aneurysms with Branched Stent-grafts.
  • 2008
  • Ingår i: European journal of vascular and endovascular surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; 35, s. 677-684
  • Tidskriftsartikel (refereegranskat)abstract
    • INTRODUCTION: Branched iliac stent-grafts (bSG) have recently been developed in order to preserve internal iliac artery (IIA) flow in patients with aneurysmal or short common iliac arteries. The aim of this study is to evaluate a single-center experience with bSG for the IIA. METHODS: Twenty-two male patients (70 (IQR 65-79) years old) underwent EVAR with 23 bSG (1 bilateral repair) between September 2002 and August 2007. Median AAA diameter was 52 (37-60) mm while common iliac diameter on the side of the bSG was 34 (27-41) mm. Two in-house modified Zenith SG and subsequently 21 commercially available bSG (18 Zenith Iliac Side and 3 Helical Branches) were used. Follow-up (FU) included CT at one month and yearly thereafter. Data was prospectively entered in a database. RESULTS: Primary technical success was 91% (21 bSG). Median FU duration was 20 (8-31) months. One patient (5 %) died after discharge from acute myocardial infarction on day 13. Another patient died 30 months after EVAR of an unrelated cause. The overall bSG patency was 74% due to 6 branch occlusions (2 intraoperative and 4 late). All patients with patent bSG were asymptomatic. Three occlusions were asymptomatic findings on CT, while the other three developed claudication (two patients with contralateral IIA occlusion and one with simultaneous occlusion of the external iliac). One patient (5%) developed an asymptomatic type III endoleak at 1 month and was successfully treated with a bridging SG. Overall, four patients (18%) required reinterventions (1 bilateral stenting of the external iliac arteries, 1 external and 1 internal SG extensions and 1 femoro-femoral cross-over bypass). Nine out of 16 patients (56%) with CT-FU>/=1 year had shrinking aneurysms. There were no postoperative aneurysm expansions. CONCLUSIONS: EVAR of aortoiliac aneurysms with IIA bSG is a good alternative to occlusion of the IIA in patients with challenging distal anatomy.
  •  
6.
  • Dias, Nuno, et al. (författare)
  • Intra-aneurysm Sac Pressure in Patients with Unchanged AAA Diameter after EVAR.
  • 2010
  • Ingår i: European journal of vascular and endovascular surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; 39, s. 35-41
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To study intra-aneurysm sac pressure and subsequent abdominal aortic aneurysm (AAA) diameter changes in patients without endoleaks that remain unchanged in AAA diameter more than 1 year after endovascular aneurysm repair (EVAR). METHODS: A total of 23 patients underwent direct intra-aneurysm sac pressure (DISP) measurements 16 months (IQR: 14-35 months) after EVAR. Tip-pressure sensors were used through translumbar AAA puncture. Mean pressure index (MPI) was calculated as the percentage of mean intra-aneurysm pressure relative to the simultaneous mean intra-aortic pressure. Aneurysm expansion or shrinkage was assumed whenever the diameter change was >/=5mm. Values are presented as median and interquartile range. RESULTS: In 18 patients, no fluid was obtained upon AAA puncture (group A). In five patients, fluid was obtained (group B). In group A, follow-up continued for 29 months (IQR: 15-35 months) after DISP; five AAAs shrank, 10 remained unchanged and three expanded (MPIs of 26% (IQR: 18-42%), 28% (IQR: 20-48%) and 63% (IQR: 47-83%) and intra-sac pulse pressures of 3mmHg (IQR: 0-5mmHg), 4mmHg (IQR: 2-8mm Hg) and 12mmHg (IQR: 6-20mmHg), respectively, for the three subgroups). MPI and intra-sac pulse pressures were higher in AAAs that subsequently expanded (P=0.073 and 0.017, respectively). MPI and pulse pressure correlated with total diameter change (r=0.49, P=0.039 and r =0.39, P=0.109, respectively). Pulse pressure had a greater influence than MPI on diameter change (R(2)=0.346, P=0.041, beta standardised coefficient of 0.121 for MPI and 0.502 for pulse pressure). Similar results with stronger, and significant correlation to pulse pressure were obtained when relative diameter changes were used (r=0.55, P=0.017). In group B, MPI and AAA pulse pressure were 32% (IQR: 18-37%) and 1mmHg (IQR: 0-6mmHg), respectively. After 36 months (IQR: 21-38 months), one AAA shrank, three continued unchanged while one expanded. CONCLUSIONS: AAAs without endoleak and unchanged diameter more than 1 year after EVAR will often continue unchanged. Expansion can eventually occur in the absence of intra-sac fluid accumulation and is associated with higher and more pulsatile intra-sac pressure. However, in patients with intra-sac fluid, expansion can occur with low intra-sac pressures.
  •  
7.
  • Dias, Nuno, et al. (författare)
  • Is There a Benefit of Frequent CT Follow-up After EVAR?
  • 2009
  • Ingår i: European journal of vascular and endovascular surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; Feb 20, s. 425-430
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: Imaging follow-up (FU) after endovascular aneurysm repair (EVAR) is usually performed by periodic contrast-enhanced computed tomography (CT) scans. This study aims to evaluate the effectiveness of CT-FU after EVAR. METHODS: In this study, 279 of 304 consecutive patients (261 male, aged 74 years (interquartile range (IQR): 70-79 years) with a median abdominal aortic aneurysm (AAA) diameter of 58mm (IQR: 53-67mm)) underwent at least one of the yearly CT scans and plain abdominal films after EVAR. All patients received Zenith stent-grafts for non-ruptured AAAs at a single institution. Patients were considered asymptomatic when a re-intervention was done solely due to an imaging FU finding. The data were prospectively entered in a computer database and retrospectively analysed. RESULTS: As a follow-up, 1167 CT scans were performed at a median of 54 months (IQR: 34-74 months) after EVAR. Twenty-seven patients exhibited postoperative AAA expansion (a 5-year expansion-free rate of 88+/-2%), and 57 patients underwent 78 postoperative re-interventions with a 5-year secondary success rate of 91+/-2%. Of the 279 patients, 26 (9.3%) undergoing imaging FU benefitted from the yearly CT scans, since they had re-interventions based on asymptomatic imaging findings: AAA diameter expansion with or without endoleaks (n=18), kink in the stent-graft limbs (n=4), endoleak type III due to stent-graft limb separation without simultaneous AAA expansion (n=2), isolated common iliac artery expansion (n=1) and superior mesenteric artery malperfusion due to partial coverage by the stent-graft fabric (n=1). CONCLUSIONS: Less than 10% of the patients benefit from the yearly CT-FU after EVAR. Only one re-intervention due to partial coverage of a branch by the stent-graft would have been delayed if routine FU had been based on simple diameter measurements and plain abdominal radiograph. This suggests that less-frequent CT is sufficient in the majority of patients, which may simplify the FU protocol, reduce radiation exposure and the total costs of EVAR. Contrast-enhanced CT scans continue, nevertheless, to be critical when re-interventions are planned.
  •  
8.
  •  
9.
  • Hinchliffe, R J, et al. (författare)
  • Observations on the Failure of Stent-Grafts in the Aortic Arch.
  • 2007
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; 34:4, s. 6-451
  • Tidskriftsartikel (refereegranskat)abstract
    • Abstract INTRODUCTION: The results of endovascular stent-grafts in the abdominal aorta and descending thoracic aorta have been encouraging. Expanding the use of thoracic stent-grafts in to the aortic arch has been associated with increasing numbers of complications. Recently isolated cases of stent-graft collapse have been reported. METHODS: This was a multi-centre European case series. Data was collected retrospectively on seven patients from five experienced endovascular centres with thoracic stent-graft collapse. RESULTS: Of the seven patients four were treated for traumatic aortic rupture. Six were male, median age 33 (range 17-54) years. During the ensuing 2 months all patients suffered stent-graft collapse. This was symptomatic in 3 patients and the rest were identified on CT. Endovascular management was possible in 6/7 patients using either a balloon expandable stent (n=6) or further stent-graft (n=1). Two patients had persistent type I endoleak despite treatment. Two of the 7 patients died, both of which presented with symptomatic thoracic stent-graft occlusion. Both deaths were a direct result of stent-graft collapse. CONCLUSIONS: Thoracic stent-graft collapse may be asymptomatic underscoring the importance of stent-graft surveillance. Endovascular management of collapse is possible in most cases using a large balloon expandable stent. Symptomatic collapse is associated with high morbidity and mortality.
  •  
10.
  • Holst, Jan, et al. (författare)
  • Early and Intermediate Outcome of Emergency Endovascular Aneurysm Repair of Ruptured Infrarenal Aortic Aneurysm: A Single-Centre Experience of 90 Consecutive Patients.
  • 2009
  • Ingår i: European journal of vascular and endovascular surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; 37, s. 413-419
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To evaluate the early and intermediate outcome of a consecutive series of emergency endovascular aneurysm repairs (eEVAR) of computed tomography (CT)-verified infrarenal ruptured abdominal aortic aneurysm (rAAA) at a single tertiary referral centre. METHODS: Prospectively collected data of patients operated between April 2000 and October 2007 were retrospectively reviewed and all their pre-, intra- and postoperative imaging were re-evaluated. Patient and procedural data were analysed using a Cox multiregression model. RESULTS: Ninety patients (86% men, aged 76 (+/-7) years), were identified and included in the analysis. Symptom duration was <3h in 22% of patients, 3-24h in 39% and >24h in 39%. Mean aneurysmal diameter was 73 (+/-14)mm. All patients were treated with the COOK Zenith((R)) stent-graft (56% bi-iliac and 44% uni-iliac). Sixty-one percent were haemodynamically unstable on presentation, and 26% required an intra-operative aortic occlusion balloon to maintain haemodynamic stability. The 30-day and 1-year mortality rates were 27% and 37%, respectively. One-year aneurysm-related mortality was 33%. Twenty-eight percent of patients required re-interventions during the follow-up. The use of an aortic occlusion balloon and the presence of cerebrovascular disease or obstructive lung disorder correlated significantly with 30-day mortality in the multivariate analysis. CONCLUSION: EVAR is a valid treatment option for rAAA when used as a first-line method for all patients.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 30

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy