SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1094 4087 ;pers:(Andreasson Jakob)"

Sökning: L773:1094 4087 > Andreasson Jakob

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Andreasson, Jakob, et al. (författare)
  • Automated identification and classification of single particle serial femtosecond X-ray diffraction data
  • 2014
  • Ingår i: Optics Express. - 1094-4087. ; 22:3, s. 2497-2510
  • Tidskriftsartikel (refereegranskat)abstract
    • The first hard X-ray laser, the Linac Coherent Light Source (LCLS), produces 120 shots per second. Particles injected into the X-ray beam are hit randomly and in unknown orientations by the extremely intense X-ray pulses, where the femtosecond-duration X-ray pulses diffract from the sample before the particle structure is significantly changed even though the sample is ultimately destroyed by the deposited X-ray energy. Single particle X-ray diffraction experiments generate data at the FEL repetition rate, resulting in more than 400,000 detector readouts in an hour, the data stream during an experiment contains blank frames mixed with hits on single particles, clusters and contaminants. The diffraction signal is generally weak and it is superimposed on a low but continually fluctuating background signal, originating from photon noise in the beam line and electronic noise from the detector. Meanwhile, explosion of the sample creates fragments with a characteristic signature. Here, we describe methods based on rapid image analysis combined with ion Time-of-Flight (ToF) spectroscopy of the fragments to achieve an efficient, automated and unsupervised sorting of diffraction data. The studies described here form a basis for the development of real-time frame rejection methods, e. g. for the European XFEL, which is expected to produce 100 million pulses per hour. (C)2014 Optical Society of America
  •  
2.
  • Aquila, Andrew, et al. (författare)
  • Time-resolved protein nanocrystallography using an X-ray free-electron laser
  • 2012
  • Ingår i: Optics Express. - 1094-4087. ; 20:3, s. 2706-2716
  • Tidskriftsartikel (refereegranskat)abstract
    • We demonstrate the use of an X-ray free electron laser synchronized with an optical pump laser to obtain X-ray diffraction snapshots from the photoactivated states of large membrane protein complexes in the form of nanocrystals flowing in a liquid jet. Light-induced changes of Photosystem I-Ferredoxin co-crystals were observed at time delays of 5 to 10 µs after excitation. The result correlates with the microsecond kinetics of electron transfer from Photosystem I to ferredoxin. The undocking process that follows the electron transfer leads to large rearrangements in the crystals that will terminally lead to the disintegration of the crystals. We describe the experimental setup and obtain the first time-resolved femtosecond serial X-ray crystallography results from an irreversible photo-chemical reaction at the Linac Coherent Light Source. This technique opens the door to time-resolved structural studies of reaction dynamics in biological systems.
  •  
3.
  • Glownia, James M., et al. (författare)
  • Time-resolved pump-probe experiments at the LCLS
  • 2010
  • Ingår i: Optics Express. - 1094-4087. ; 18:17, s. 17620-17630
  • Tidskriftsartikel (refereegranskat)abstract
    • The first time-resolved x-ray/optical pump-probe experiments at the SLAC Linac Coherent Light Source (LCLS) used a combination of feedback methods and post-analysis binning techniques to synchronize an ultrafast optical laser to the linac-based x-ray laser. Transient molecular nitrogen alignment revival features were resolved in time-dependent x-ray-induced fragmentation spectra. These alignment features were used to find the temporal overlap of the pump and probe pulses. The strong-field dissociation of x-ray generated quasi-bound molecular dications was used to establish the residual timing jitter. This analysis shows that the relative arrival time of the Ti:Sapphire laser and the x-ray pulses had a distribution with a standard deviation of approximately 120 fs. The largest contribution to the jitter noise spectrum was the locking of the laser oscillator to the reference RF of the accelerator, which suggests that simple technical improvements could reduce the jitter to better than 50 fs.
  •  
4.
  • Hort, O., et al. (författare)
  • High-flux source of coherent XUV pulses for user applications
  • 2019
  • Ingår i: Optics Express. - 1094-4087 .- 1094-4087. ; 27:6, s. 8871-8883
  • Tidskriftsartikel (refereegranskat)abstract
    • We present experimental results obtained at a user-oriented XUV beamline implemented at the ELI Beamlines facility. The coherent XUV radiation is produced via high harmonic generation in gases in a loose focusing geometry. The heamline is designed to be driven by 1 kHz, 100 mJ, 20 Is pulses centered at a wavelength of 830 nm. Results such as XUV spectra, beam wavefront and pulse energy obtained during the heamline commissioning with a commercial 1 kHz, 5 mJ, 40 fs laser system are presented. A unique XUV spectrometer for source characterization designed to reach a very high sensitivity is described in detail, and we demonstrate a novel technique for single shot and every shot. XUV pulse energy measurement. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement.
  •  
5.
  • Nelson, A. J., et al. (författare)
  • Soft x-ray free electron laser microfocus for exploring matter under extreme conditions
  • 2009
  • Ingår i: Optics Express. - 1094-4087. ; 17:20, s. 18271-18278
  • Tidskriftsartikel (refereegranskat)abstract
    • We have focused a beam (BL3) of FLASH (Free-electron LASer in Hamburg: lambda = 13.5 nm, pulse length 15 fs, pulse energy 10-40 mu J, 5Hz) using a fine polished off-axis parabola having a focal length of 270 mm and coated with a Mo/Si multilayer with an initial reflectivity of 67% at 13.5 nm. The OAP was mounted and aligned with a picomotor controlled six-axis gimbal. Beam imprints on poly(methyl methacrylate) -PMMA were used to measure focus and the focused beam was used to create isochoric heating of various slab targets. Results show the focal spot has a diameter of <= 1 mu m. Observations were correlated with simulations of best focus to provide further relevant information.
  •  
6.
  • Oelze, Tim, et al. (författare)
  • THz streak camera performance for single-shot characterization of XUV pulses with complex temporal structures
  • 2020
  • Ingår i: Optics Express. - : OPTICAL SOC AMER. - 1094-4087. ; 28:14, s. 20686-20703
  • Tidskriftsartikel (refereegranskat)abstract
    • The THz-field-driven streak camera has proven to be a powerful diagnostic-technique that enables the shot-to-shot characterization of the duration and the arrival time jitter of free electron laser (FEL) pulses. Here we investigate the performance of three computational approaches capable to determine the duration of FEL pulses with complex temporal structures from single-shot measurements of up to three simultaneously recorded spectra. We use numerically simulated FEL pulses in order to validate the accuracy of the pulse length retrieval in average as well as in a single-shot mode. We discuss requirements for the THz field strength in order to achieve reliable results and compare our numerical study with the analysis of experimental data that were obtained at the FEL in Hamburg - FLASH. (C) 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
  •  
7.
  • Rath, Asawari D., et al. (författare)
  • Explosion dynamics of sucrose nanospheres monitored by time of flight spectrometry and coherent diffractive imaging at the split-and-delay beam line of the FLASH soft X-ray laser
  • 2014
  • Ingår i: Optics Express. - 1094-4087. ; 22:23, s. 28914-28925
  • Tidskriftsartikel (refereegranskat)abstract
    • We use a Mach-Zehnder type autocorrelator to split and delay XUV pulses from the FLASH soft X-ray laser for triggering and subsequently probing the explosion of aerosolised sugar balls. FLASH was running at 182 eV photon energy with pulses of 70 fs duration. The delay between the pump-probe pulses was varied between zero and 5 ps, and the pulses were focused to reach peak intensities above 1016 W/cm2 with an off-axis parabola. The direct pulse triggered the explosion of single aerosolised sucrose nano-particles, while the delayed pulse probed the exploding structure. The ejected ions were measured by ion time of flight spectrometry, and the particle sizes were measured by coherent diffractive imaging. The results show that sucrose particles of 560-1000 nm diameter retain their size for about 500 fs following the first exposure. Significant sample expansion happens between 500 fs and 1 ps. We present simulations to support these observations.
  •  
8.
  • Yoon, Chun Hong, et al. (författare)
  • Unsupervised classification of single-particle X-ray diffraction snapshots by spectral clustering
  • 2011
  • Ingår i: Optics Express. - 1094-4087. ; 19:17, s. 16542-16549
  • Tidskriftsartikel (refereegranskat)abstract
    • Single-particle experiments using X-ray Free Electron Lasers produce more than 10(5) snapshots per hour, consisting of an admixture of blank shots (no particle intercepted), and exposures of one or more particles. Experimental data sets also often contain unintentional contamination with different species. We present an unsupervised method able to sort experimental snapshots without recourse to templates, specific noise models, or user-directed learning. The results show 90% agreement with manual classification.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy