SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1356 689X ;pers:(Dedering Åsa)"

Sökning: L773:1356 689X > Dedering Åsa

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Peterson, Gunnel, et al. (författare)
  • Altered ventral neck muscle deformation for individuals with whiplash associated disorder compared to healthy controls : A case-control ultrasound study
  • 2015
  • Ingår i: Manual Therapy. - : Elsevier. - 1356-689X .- 1532-2769. ; 20:2, s. 319-327
  • Tidskriftsartikel (refereegranskat)abstract
    • Previous studies have shown altered neck muscle function in individuals with chronic whiplash associated disorder (WAD). However, we lack real-time investigations with non-invasive methods that can distinguish between the different ventral neck muscle layers. This study investigated deformations and deformation rates in the sternocleidomastoid (SCM), longus capitis (Lcap), and longus colli (Lco) muscles with real-time ultrasonography. Twenty-six individuals with WAD were compared with 26 controls, matched for age and sex. Ultrasound imaging of the SCM, Lcap, and Lco were recorded during 10 repetitive arm elevations. The first and tenth arm elevations were post-process analyzed with speckle tracking. There were few significant differences in the deformations or deformation rates in the SCM, Lcap, and Lco between the WAD and control group. In controls, deformations and deformation rates showed linear positive relationships between SCM/Lcap, SCM/Lco, and Lcap/Lco which increased from the first arm elevation (R-2 = 0.14-0.70); to the tenth arm elevation (R-2 = 0.51-0.71). The WAD group showed similar or weaker linear relationship (R-2 < 0.19) during the tenth compared to the first (R-2 < 0.44) arm elevation except for deformations in Lcap/Lco (R-2 = 0.13-0.57). This result indicated that deformations and deformation rates in one muscle were correlated by similar deformations and deformation rates in other neck muscles in the control group, but this interplay between muscles was not found in the WAD group. (C) 2014 Elsevier Ltd. All rights reserved.
  •  
2.
  • Wibault, Johanna, et al. (författare)
  • Using the cervical range of motion (CROM) device to assess head repositioning accuracy in individuals with cervical radiculopathy in comparison to neck- healthy individuals
  • 2013
  • Ingår i: Manual Therapy. - : Elsevier. - 1356-689X .- 1532-2769. ; 18:5, s. 403-409
  • Tidskriftsartikel (refereegranskat)abstract
    • This study had two purposes: to compare head repositioning accuracy (HRA) using the cervical range of motion (CROM) device between individuals with cervical radiculopathy caused by disc disease (CDD; n = 71) and neck- healthy individuals (n = 173); and to evaluate the test–retest reliability of the CROM device in individuals with CDD, and criterion validity between the CROM device and a laser in neck-healthy individuals, with quantification of measurement errors. Parameters of reliability and validity were expressed with intra- class- correlation coefficients (ICCs), and measurement errors with standard error of measurement (SEM) and Bland Altman limits of agreement. HRA (Mdn, IQR) differed significantly between individuals with CDD and neck- healthy individuals after rotation right 2.7° (6.0), 1.7° (2.7); and rotation left 2.7° (3.3), 1.3° (2.7) (p < = 0.021); 31% of individuals with CDD were classified as having impairment in HRA. The test–retest reliability of the CROM device in individuals with CDD showed ICCs of 0.79- 0.85, and SEMs of 1.4°- 2°. The criterion validity between the CROM device and the laser in neck-healthy individuals showed ICCs of 0.43- 0.91 and SEMs of 0.8°- 1.3°. The results support the use of the CROM device for quantifying HRA impairment in individuals with CDD in clinical practice; however, criterion validity between the CROM device and a laser in neck-healthy individuals was questionable. HRA impairment in individuals with CDD may be important to consider during rehabilitation and evaluated with the criterion established with the CROM device in neck-healthy individuals.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy