1.
  • Ceberg, Sofie, et al. (författare)
  • Modelling the dynamic dose response of an nMAG polymer gel dosimeter.
  • 2012
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 1361-6560 .- 0031-9155. ; 57:15, s. 4845-4853
  • Tidskriftsartikel (refereegranskat)abstract
    • Gel dosimetry measures the absorbed radiation dose with high spatial resolution in 3D. However, recently published data show that the response of metacrylic-based polymer gels depends on the segmented delivery pattern, which could potentially be a considerable disadvantage for measurements of modern dynamic radiotherapy techniques. The aim of this study is to design a dynamic compartment model for the response of a gel dosimeter, exposed to an arbitrary irradiation pattern (segmented delivery and intensity modulation), in order to evaluate the associated effects on absorbed dose measurements. The model is based on the separation of the protons affecting the magnetic resonance signal (i.e. the R2 value) into six compartments, described by a set of differential equations. The model is used to calculate R2 values for a number of different segmented delivery patterns between 0-4 Gy over 1-33 fractions. Very good agreement is found between calculated and measured R2 values, with an average difference of 0.3 ± 1.1% (1 SD). The model is also used to predict the behaviour of a gel dosimeter exposed to irradiation according to typical IMRT, VMAT and respiratory gating scenarios. The calculated R2 values are approximately independent of the segmented delivery, given that the same total dose is delivered during the same total time. It is concluded that this study helps to improve the theoretical understanding of the dependence of metacrylic-based polymer gel response to segmented radiation delivery.
  •  
2.
  • Ceberg, Sofie, et al. (författare)
  • RapidArc treatment verification in 3D using polymer gel dosimetry and Monte Carlo simulation.
  • 2010
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 1361-6560 .- 0031-9155. ; 55:17, s. 4885-4898
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to verify the advanced inhomogeneous dose distribution produced by a volumetric arc therapy technique (RapidArc) using 3D gel measurements and Monte Carlo (MC) simulations. The TPS (treatment planning system)-calculated dose distribution was compared with gel measurements and MC simulations, thus investigating any discrepancy between the planned dose delivery and the actual delivery. Additionally, the reproducibility of the delivery was investigated using repeated gel measurements. A prostate treatment plan was delivered to a 1.3 liter nPAG gel phantom using one single arc rotation and a target dose of 3.3 Gy. Magnetic resonance imaging of the gel was carried out using a 1.5 T scanner. The MC dose distributions were calculated using the VIMC-Arc code. The relative absorbed dose differences were calculated voxel-by-voxel, within the volume enclosed by the 90% isodose surface (VOI(90)), for the TPS versus gel and TPS versus MC. The differences between the verification methods, MC versus gel, and between two repeated gel measurements were investigated in the same way. For all volume comparisons, the mean value was within 1% and the standard deviation of the differences was within 2.5% (1SD). A 3D gamma analysis between the dose matrices were carried out using gamma criteria 3%/3 mm and 5%/5 mm (% dose difference and mm distance to agreement) within the volume enclosed by the 50% isodose surface (VOI(50)) and the 90% isodose surface (VOI(90)), respectively. All comparisons resulted in very high pass rates. More than 95% of the TPS points were within 3%/3 mm of both the gel measurement and MC simulation, both inside VOI(50) and VOI(90). Additionally, the repeated gel measurements showed excellent consistency, indicating reproducible delivery. Using MC simulations and gel measurements, this verification study successfully demonstrated that the RapidArc plan was both accurately calculated and delivered as planned.
  •  
3.
  • Ceberg, Sofie, et al. (författare)
  • Verification of dynamic radiotherapy: the potential for 3D dosimetry under respiratory-like motion using polymer gel.
  • 2008
  • Ingår i: Physics in Medicine and Biology. - 1361-6560. ; 53:20, s. 387-396
  • Tidskriftsartikel (refereegranskat)abstract
    • Following the implementation of advanced treatment procedures in radiotherapy, there is a need for dynamic dose verification in 3D. Gel dosimetry could potentially be used for such measurements. However, recently published data show that certain types of gels have a dose rate and fractionation dependence. The aim of this study was to investigate the feasibility of using a polymer gel dosimeter for dose verification of dynamic radiotherapy. To investigate the influence of dose rate dependence during respiratory-like motion in and out of the beam, a respiration robot together with two types of gel systems (normoxic methacrylic acid gel (nMAG) and normoxic polyacrylamide gel (nPAG)) were used. Reference measurements were obtained using a linear diode array (LDA). Expected results, if there was no influence of the dose rate variation, were calculated by convolving the static irradiated gel data with the motion function controlling the robot. To investigate the fractionation dependence, the gels were irradiated using gated and ungated deliveries. Magnetic resonance imaging was used to evaluate the absorbed dose response of the gel. The measured gel data coincided well with the LDA data. Also, the calculated data agreed well with the measured dynamic gel data, i.e. no dose rate dependence due to motion was observed. The difference in the R2 response for the gels receiving ungated and gated, i.e. fractionated, deliveries was less than 1% for the nPAG and 4% for the nMAG, for absorbed doses up to 2 Gy. The maximum difference was 1.2% for the nPAG and 9% for the nMAG, which occurred at the highest given dose (4 Gy). The investigated gels were found to be feasible detectors for dose measurements under respiratory-like motion. For dose verification of dynamic RT involving gated delivery, e.g. breathing-adapted radiotherapy, relative absorbed dose evaluation should be used in order to minimize the effects of fractionated irradiation.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  • Karlsson, Anna, et al. (författare)
  • Dose integration characteristics in normoxic polymer gel dosimetry investigated using sequential beam irradiation
  • 2007
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 1361-6560 .- 0031-9155. ; 52:15, s. 4697-4706
  • Tidskriftsartikel (refereegranskat)abstract
    • Dose integration properties were investigated for normoxic polymer gels based on methacrylic acid (nMAG) and acrylamide/ N, N'-methylenebisacrylamide (nPAG). The effect of sequential irradiation was studied for different fractionation schemes and varying amounts of methacrylic acid for the nMAG gels. Magnetic resonance imaging (MRI) was used for read out of the absorbed dose response. The investigated gels exhibited a dependence on the fractionation scheme. The response when the total dose was divided into fractions of 0.5 Gy was compared with the response when the total dose was delivered in a single fraction. The slope of the R2 versus the absorbed dose response decreased when the absorbed dose per fraction was increased. Also, for higher amounts of methacrylic acid in the nMAG system the difference in the response increased. For gels containing 2, 4, 6 and 8% methacrylic acid, the R2 versus the absorbed dose response increased by 35, 37, 63 and 93%, respectively. Furthermore, the effect of the fractionation was larger when a higher total absorbed dose was given. The effect was less pronounced for the investigated nPAG, containing 3% acrylamide and 3% N, N'-methylenebisacrylamide, than for the nMAG systems. Consequently, this study indicates that the nPAG system has preferable beam integration characteristics compared with the nMAG system.
  •  