SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1361 6560 ;pers:(Johansson Lennart)"

Sökning: L773:1361 6560 > Johansson Lennart

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Andersson, Martin, et al. (författare)
  • A biokinetic and dosimetric model for ionic indium in humans
  • 2017
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 62:16, s. 6397-6407
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper reviews biokinetic data for ionic indium, and proposes a biokinetic model for systemic indium in adult humans. The development of parameter values focuses on human data and indium in the form of ionic indium(III), as indium chloride and indium arsenide. The model presented for systemic indium is defined by five different pools: plasma, bone marrow, liver, kidneys and other soft tissues. The model is based on two subsystems: one corresponding to indium bound to transferrin and one where indium is transported back to the plasma, binds to red blood cell transferrin and is then excreted through the kidneys to the urinary bladder. Absorbed doses to several organs and the effective dose are calculated for 111In- and 113mIn-ions. The proposed biokinetic model is compared with previously published biokinetic indium models published by the ICRP. The absorbed doses are calculated using the ICRP/ICRU adult reference phantoms and the effective dose is estimated according to ICRP Publication 103. The effective doses for 111In and 113mIn are 0.25 mSv MBq-1 and 0.013 mSv MBq-1 respectively. The updated biokinetic and dosimetric models presented in this paper take into account human data and new animal data, which represent more detailed and presumably more accurate dosimetric data than that underlying previous models for indium.
  •  
2.
  • Andersson, Martin, et al. (författare)
  • Improved estimates of the radiation absorbed dose to the urinary bladder wall
  • 2014
  • Ingår i: Physics in Medicine and Biology. - : Institute of Physics Publishing (IOPP). - 0031-9155 .- 1361-6560. ; 59:9, s. 2173-2182
  • Tidskriftsartikel (refereegranskat)abstract
    • Specific absorbed fractions (SAFs) have been calculated as a function of the content in the urinary bladder in order to allow more realistic calculations of the absorbed dose to the bladder wall. The SAFs were calculated using the urinary bladder anatomy from the ICRP male and female adult reference computational phantoms. The urinary bladder and its content were approximated by a sphere with a wall of constant mass, where the thickness of the wall depended on the amount of urine in the bladder. SAFs were calculated for males and females with 17 different urinary bladder volumes from 10 to 800 mL, using the Monte Carlo computer program MCNP5, at 25 energies of mono-energetic photons and electrons ranging from 10 KeV to 10 MeV. The decay was assumed to be homogeneously distributed in the urinary bladder content and the urinary bladder wall, and the mean absorbed dose to the urinary bladder wall was calculated. The Monte Carlo simulations were validated against measurements made with thermoluminescent dosimeters. The SAFs obtained for a urine volume of 200 mL were compared to the values calculated for the urinary bladder wall using the adult reference computational phantoms. The mean absorbed dose to the urinary wall from F-18-FDG was found to be 77 mu Gy/MBq formales and 86 mu Gy/MBq for females, while for (99)mTc-DTPA the mean absorbed doses were 80 mu Gy/MBq for males and 86 mu Gy/MBq for females. Compared to calculations using a constant value of the SAF from the adult reference computational phantoms, the mean absorbed doses to the bladder wall were 60% higher for F-18-FDG and 30% higher for (99)mTc-DTPA using the new SAFs.
  •  
3.
  • Johansson, Erik, et al. (författare)
  • Liquid ionization chamber initial recombination dependence on LET for electrons and photons
  • 2013
  • Ingår i: Physics in Medicine and Biology. - : Institute of Physics Publishing (IOPP). - 0031-9155 .- 1361-6560. ; 58:12, s. 4225-4236
  • Tidskriftsartikel (refereegranskat)abstract
    • The possibility of indirect measurements of linear energy transfer (LET) with a liquid ionization chamber (LIC) has been investigated by studying initial recombination losses at different applied voltages. A linear fit is made to the voltage-signal curve and the intersection point of the fit and the voltage-axis is shown to correlate with LET. The LIC applied voltages were 100-700 V, which corresponds to electric field strengths between 0.3 and 2.0 MV m(-1). Several different photon and electron beams have been studied, and by using MCNPX (TM) the respective LET spectra have been determined. The beam qualities in this study were found to have a fluence averaged LET between 0.17 and 1.67 keV mu m(-1) and a corresponding dose averaged LET between 0.97 and 4.62 keV mu m(-1). For the experimental data in this study the linear fit method yields consistent results with respect to Monte Carlo simulated LET values. A calibration curve for LET determination is provided for the LIC used in the present work.
  •  
4.
  • Larsson, Anne, et al. (författare)
  • Correction for scatter and septal penetration using convolution subtraction methods and model-based compensation in I-123 brain SPECT imaging - a Monte Carlo study
  • 2006
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 1361-6560 .- 0031-9155. ; 51:22, s. 5753-5767
  • Tidskriftsartikel (refereegranskat)abstract
    • Scatter and septal penetration deteriorate contrast and quantitative accuracy in single photon emission computed tomography ( SPECT). In this study four different correction techniques for scatter and septal penetration are evaluated for I-123 brain SPECT. One of the methods is a form of model-based compensation which uses the effective source scatter estimation ( ESSE) for modelling scatter, and collimator-detector response ( CDR) including both geometric and penetration components. The other methods, which operate on the 2D projection images, are convolution scatter subtraction ( CSS) and two versions of transmission dependent convolution subtraction ( TDCS), one of them proposed by us. This method uses CSS for correction for septal penetration, with a separate kernel, and TDCS for scatter correction. The corrections are evaluated for a dopamine transporter ( DAT) study and a study of the regional cerebral blood flow ( rCBF), performed with I-123. The images are produced using a recently developed Monte Carlo collimator routine added to the program SIMIND which can include interactions in the collimator. The results show that the method included in the iterative reconstruction is preferable to the other methods and that the new TDCS version gives better results compared with the other 2D methods.
  •  
5.
  • Larsson, Anne, et al. (författare)
  • Scatter-to-primary based scatter fractions for transmission dependent convolution subtraction of SPECT images
  • 2003
  • Ingår i: Physics in Medicine and Biology. - 0031-9155 .- 1361-6560. ; 48:22, s. N323-N328
  • Tidskriftsartikel (refereegranskat)abstract
    • In single photon emission computed tomography (SPECT), transmission-dependent convolution subtraction has been shown to be useful when correcting for scattered events. The method is based on convolution subtraction, but includes a matrix of scatter fractions instead of a global scatter fraction. The method can be extended to iteratively improve the scatter estimate, but in this note we show that this requires a modification of the theory to use scatter-to-total scatter fractions for the first iteration only and scatter-to-primary fractions thereafter. To demonstrate this, scatter correction is performed on a Monte Carlo simulated image of a point source of activity in water. The modification of the theory is compared to corrections where the scatter fractions are based on the scatter-to-total ratio, using one and ten iterations. The resulting ratios of subtracted to original counts are compared to the true scatter-to-total ratio of the simulation and the most accurate result is found for our modification of the theory.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy