SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1437 4331 ;pers:(Andreasson Ulf 1968)"

Sökning: L773:1437 4331 > Andreasson Ulf 1968

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Andreasson, Ulf, 1968, et al. (författare)
  • Assessing the commutability of candidate reference materials for the harmonization of neurofilament light measurements in blood
  • 2023
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 61:7, s. 1245-1254
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives Neurofilament light chain (NfL) concentration in blood is a biomarker of neuro-axonal injury in the nervous system and there now exist several assays with high enough sensitivity to measure NfL in serum and plasma. There is a need for harmonization with the goal of creating a certified reference material (CRM) for NfL and an early step in such an effort is to determine the best matrix for the CRM. This is done in a commutability study and here the results of the first one for NfL in blood is presented.Methods Forty paired individual serum and plasma samples were analyzed for NfL on four different analytical platforms. Neat and differently spiked serum and plasma were evaluated for their suitability as a CRM using the difference in bias approach.Results The correlation between the different platforms with regards to measured NfL concentrations were very high (Spearman's rho >= 0.96). Samples spiked with cerebrospinal fluid (CSF) showed higher commutability compared to samples spiked with recombinant human NfL protein and serum seems to be a better choice than plasma as the matrix for a CRM.Conclusions The results from this first commutability study on NfL in serum/plasma showed that it is feasible to create a CRM for NfL in blood and that spiking should be done using CSF rather than with recombinant human NfL protein.
  •  
2.
  • Andreasson, Ulf, 1968, et al. (författare)
  • Commutability of the certified reference materials for the standardization of beta-amyloid 1-42 assay in human cerebrospinal fluid: lessons for tau and beta-amyloid 1-40 measurements
  • 2018
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 56:12, s. 2058-2066
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The core Alzheimer's disease cerebrospinal fluid (CSF) biomarkers total tau (T-tau), phosphorylated tau (P-tau), beta-amyloid 1-42 (A beta 42) and beta-amyloid 1-40 (A beta 40) are increasing in importance and are now part of the research criteria for the diagnosis of the disease. The main aim of this study is to evaluate whether a set of certified reference materials (CRMs) are commutable for A beta 42 and to serve as a feasibility study for the other markers. This property is a prerequisite for the establishment of CRMs which will then be used by manufacturers to calibrate their assays against. Once the preanalytical factors have been standardized and proper selection criteria are available for subject cohorts this harmonization between methods will allow for universal cut-offs to be determined. Methods: Thirty-four individual CSF samples and three different CRMs where analyzed for T-tau, P-tau, A beta 42 and A beta 40, using up to seven different commercially available methods. For A beta 40 and A beta 42 a mass spectrometry-based procedure was also employed. Results: There were strong pairwise correlations between the different methods (Spearman's p>0.92) for all investigated analytes and the CRMs were not distinguishable from the individual samples. Conclusions: This study shows that the CRMs are commutable for the different assays for A beta 42. For the other analytes the results show that it would be feasible to also produce CRMs for these. However, additional studies are needed as the concentration interval for the CRMs were selected based on A beta 42 concentrations only and did in general not cover satisfactory large concentration intervals for the other analytes.
  •  
3.
  • Bjerke, Maria, 1977, et al. (författare)
  • Assessing the commutability of reference material formats for the harmonization of amyloid beta measurements.
  • 2016
  • Ingår i: Clinical chemistry and laboratory medicine : CCLM / FESCC. - : Walter de Gruyter GmbH. - 1437-4331 .- 1434-6621. ; 54:7, s. 1177-91
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The cerebrospinal fluid (CSF) amyloid-β (Aβ42) peptide is an important biomarker for Alzheimer's disease (AD). Variability in measured Aβ42 concentrations at different laboratories may be overcome by standardization and establishing traceability to a reference system. Candidate certified reference materials (CRMs) are validated herein for this purpose. METHODS: Commutability of 16 candidate CRM formats was assessed across five CSF Aβ42 immunoassays and one mass spectrometry (MS) method in a set of 48 individual clinical CSF samples. Promising candidate CRM formats (neat CSF and CSF spiked with Aβ42) were identified and subjected to validation across eight (Elecsys, EUROIMMUN, IBL, INNO-BIA AlzBio3, INNOTEST, MSD, Simoa, and Saladax) immunoassays and the MS method in 32 individual CSF samples. Commutability was evaluated by Passing-Bablok regression and the candidate CRM termed commutable when found within the prediction interval (PI). The relative distance to the regression line was assessed. RESULTS: The neat CSF candidate CRM format was commutable for almost all method comparisons, except for the Simoa/MSD, Simoa/MS and MS/IBL where it was found just outside the 95% PI. However, the neat CSF was found within 5% relative distance to the regression line for MS/IBL, between 5% and 10% for Simoa/MS and between 10% and 15% for Simoa/MSD comparisons. CONCLUSIONS: The neat CSF candidate CRM format was commutable for 33 of 36 method comparisons, only one comparison more than expected given the 95% PI acceptance limit. We conclude that the neat CSF candidate CRM can be used for value assignment of the kit calibrators for the different Aβ42 methods.
  •  
4.
  • Gobom, Johan, et al. (författare)
  • Validation of the LUMIPULSE automated immunoassay for the measurement of core AD biomarkers in cerebrospinal fluid.
  • 2022
  • Ingår i: Clinical chemistry and laboratory medicine. - : Walter de Gruyter GmbH. - 1437-4331 .- 1434-6621. ; 60:2
  • Tidskriftsartikel (refereegranskat)abstract
    • The core cerebrospinal fluid (CSF) biomarkers; total tau (tTau), phospho-tau (pTau), amyloid β 1-42 (Aβ 1-42), and the Aβ 1-42/Aβ 1-40 ratio have transformed Alzheimer's disease (AD) research and are today increasingly used in clinical routine laboratories as diagnostic tools. Fully automated immunoassay instruments with ready-to-use assay kits and calibrators has simplified their analysis and improved reproducibility of measurements. We evaluated the analytical performance of the fully automated immunoassay instrument LUMIPULSE G (Fujirebio) for measurement of the four core AD CSF biomarkers and determined cutpoints for AD diagnosis.Comparison of the LUMIPULSE G assays was performed with the established INNOTEST ELISAs (Fujirebio) for hTau Ag, pTau 181, β-amyloid 1-42, and with V-PLEX Plus Aβ Peptide Panel 1 (6E10) (Meso Scale Discovery) for Aβ 1-42/Aβ 1-40, as well as with a LC-MS reference method for Aβ 1-42. Intra- and inter-laboratory reproducibility was evaluated for all assays. Clinical cutpoints for Aβ 1-42, tTau, and pTau was determined by analysis of three cohorts of clinically diagnosed patients, comprising 651 CSF samples. For the Aβ 1-42/Aβ 1-40 ratio, the cutpoint was determined by mixture model analysis of 2,782 CSF samples.The LUMIPULSE G assays showed strong correlation to all other immunoassays (r>0.93 for all assays). The repeatability (intra-laboratory) CVs ranged between 2.0 and 5.6%, with the highest variation observed for β-amyloid 1-40. The reproducibility (inter-laboratory) CVs ranged between 2.1 and 6.5%, with the highest variation observed for β-amyloid 1-42. The clinical cutpoints for AD were determined to be 409 ng/L for total tau, 50.2 ng/L for pTau 181, 526 ng/L for β-amyloid 1-42, and 0.072 for the Aβ 1-42/Aβ 1-40 ratio.Our results suggest that the LUMIPULSE G assays for the CSF AD biomarkers are fit for purpose in clinical laboratory practice. Further, they corroborate earlier presented reference limits for the biomarkers.
  •  
5.
  •  
6.
  • Minta, Karolina, et al. (författare)
  • Dynamics of extracellular matrix proteins in cerebrospinal fluid and serum and their relation to clinical outcome in human traumatic brain injury
  • 2019
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 57:10
  • Tidskriftsartikel (refereegranskat)abstract
    • Brevican, neurocan, tenascin-C and tenascin-R are extracellular matrix proteins present in brain that show increased expression in experimental animal models of brain injury. However, little is known about the dynamics of these proteins in human body fluids, such as cerebrospinal fluid (CSF) and serum, after traumatic brain injury (TBI). The aims of this study were to investigate if matrix proteins in CSF and serum are associated with functional outcome following traumatic brain injury, if their concentrations change over time and to compare their levels between brain injured patients to controls. In total, 42 traumatic brain injury patients, nine healthy controls and a contrast group consisting of 38 idiopathic normal pressure hydrocephalus patients were included. Enzyme-linked immunosorbent assays (ELISAs) were used to measure the concentrations of proteins. Increased concentrations of brevican, tenascin-C and tenascin-R in CSF correlated with unfavourable outcome, with stronger outcome prediction ability compared to other biomarkers of brain tissue injury. CSF brevican, tenascin-R and serum neurocan gradually decreased with time (p = 0.04, p = 0.008, p = 0.005, respectively), while serum tenascin-C (p = 0.01) increased. CSF concentrations of brevican, neurocan and tenascin-R (only in time point 3) after TBI were lower than in the idiopathic normal pressure hydrocephalus group (p < 0.0001, p < 0.0001, and p = 0.0008, respectively). In serum, tenascin-C concentration was higher and neurocan lower compared to healthy controls (p = 0.02 and p = 0.0009). These findings indicate that levels of extracellular matrix proteins are associated with clinical outcome following TBI and may act as markers for different pathophysiology than currently used protein biomarkers. © 2019 Walter de Gruyter GmbH, Berlin/Boston.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy