SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1437 4331 ;pers:(Rönnelid Johan)"

Sökning: L773:1437 4331 > Rönnelid Johan

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Andrade, Luis E. C., et al. (författare)
  • International consensus on antinuclear antibody patterns : definition of the AC-29 pattern associated with antibodies to DNA topoisomerase I
  • 2018
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - : WALTER DE GRUYTER GMBH. - 1434-6621 .- 1437-4331. ; 56:10, s. 1783-1788
  • Tidskriftsartikel (refereegranskat)abstract
    • The indirect immunofluorescence assay (IFA) on HEp-2 cells is the reference method for autoantibody screening. The HEp-2 IFA pattern provides useful information on the possible autoantibodies in the sample. The International Consensus on Antinuclear Antibody Patterns (ICAP) initiative seeks to define and harmonize the nomenclature of HEp-2 IFA patterns. The most relevant and usual patterns have been assigned an alphanumeric code from anti-cell (AC)-1 to AC-28 and were organized into a classification algorithm (www.ANApatterns.org). The systemic sclerosis-associated autoantibodies to DNA topoisomerase I (Topo I) produce a peculiar composite 5-element HEp-2 IFA pattern (Topo I-like pattern) comprising the staining of the nucleus, metaphase chromatin plate, nucleolar organizing region, cytoplasm and nucleolus. In a recent assessment of the European Consensus Finding Study Group on autoantibodies, a well-defined anti-Topo I sample was blindly analyzed and classified according to ICAP AC patterns by 43 participant laboratories across Europe. There were wide variations among these laboratories in reporting nuclear, nucleolar and cytoplasmic patterns, indicating the inadequacy of the existing AC patterns to report the Topo I-like pattern. Several ICAP member laboratories independently demonstrated the overall consistency of the HEp-2 IFA Topo I-like pattern using HEp-2 slides from different manufacturers. The ICAP committee reviewed 24 candidate images and selected the four most representative images to be available on the ICAP website. The proper recognition of the AC-29 pattern should trigger suspicion of the presence of anti-Topo I antibodies, which may engender appropriate analyte-specific reflex tests to confirm the autoantibody specificity.
  •  
2.
  •  
3.
  • Dellavance, Alessandra, et al. (författare)
  • Establishment of an international autoantibody reference standard for human anti-DFS70 antibodies : proof-of-concept study for a novel Megapool strategy by pooling individual specific sera
  • 2019
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - : WALTER DE GRUYTER GMBH. - 1434-6621 .- 1437-4331. ; 57:11, s. 1754-1763
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: International autoantibody standards, traditionally based on material obtained from plasmapheresis of single subjects, represent individual immune response and may not comprehend the heterogeneity of the general population. The anti-DFS70 autoantibody yields a characteristic dense fine speckled (DFS) nuclear pattern on indirect immunofluorescence assay on HEp-2 cells (HEp-2 IFA) and speaks against autoimmunity. We propose a novel strategy for developing autoantibody reference standards, based on stepwise pooling of serum samples from hundreds of individuals with anti-DFS70 antibodies.Methods: Within a 2-year period, serum samples were selected from routine HEp-2 IFA according to the following criteria: DFS HEp-2 IFA pattern at titer >= 1:640; anti-DFS70 reactivity in three analyte-specific tests (Western blot [WB], enzyme-linked immunosorbent assay [ELISA] and chemiluminescent immunoassay [CLIA]). Aliquots of individual samples were combined into progressively larger pools with stepwise validation of intermediary pools as for individual samples. Validated intermediary pools were merged into a final pool for lyophilization.Results: A total of 741 validated samples yielded a 750 mL final pool that was lyophilized into thousands of 200 mu L-aliquots. Reconstituted aliquots yielded the expected anti-DFS70 reactivity in ELISA, CLIA and WB, as well as high-titer DFS HEp-2 IFA pattern. The appropriate antiDFS70 reactivity of the lyophilized pool was confirmed by seven international expert centers, using HEp-2 IFA, ELISA, WB and immunoprecipitation.Conclusions: This proof-of-concept study provides an innovative and efficient strategy to build serum reference standards for autoantibody testing. The anti-DFS70 standard will integrate the panel of standards of Autoantibody Standardization Committee (ASC, www.autoab.org ), contributing to education for proper assay validation and interpretation of the DFS pattern and other HEp-2 IFA patterns.
  •  
4.
  • Falorni, Alberto, et al. (författare)
  • Determination of 21-hydroxylase autoantibodies: inter-laboratory concordance in the Euradrenal International Serum Exchange Program
  • 2015
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 53:11, s. 1761-1770
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: 21-Hydroxylase autoantibodies (21OHAb) are markers of an adrenal autoimmune process that identifies individuals with autoimmune Addison's disease (AAD). Quality and inter-laboratory agreement of various 21OHAb tests are incompletely known. The objective of the study was to determine inter-laboratory concordance for 21OHAb determinations. Methods: Sixty-nine sera from 51 patients with AAD and 51 sera from 51 healthy subjects were blindly coded by a randomization center and distributed to 14 laboratories that determined 21OHAb, either by an "in-house" assay (n=9) using in vitro-translated S-35-21OH or luciferase-labeled 21OH or a commercial kit with I-125-21OH (n=5). Main outcome measures were diagnostic accuracy of each participating laboratory and inter-laboratory agreement of 21OHAb assays. Results: Intra-assay coefficient of variation ranged from 2.6% to 5.3% for laboratories using the commercial kit and from 5.1% to 23% for laboratories using "in-house" assays. Diagnostic accuracy, expressed as area under ROC curve (AUC), varied from 0.625 to 0.947 with the commercial kit and from 0.562 to 0.978 with "in-house" methods. Cohen's. of inter-rater agreement was 0.603 among all 14 laboratories, 0.691 among "in-house" laboratories, and 0.502 among commercial kit users. Optimized cutoff levels, calculated on the basis of AUCs, increased the diagnostic accuracy of every laboratory (AUC >0.9 for 11/14 laboratories) and increased the Cohen's. of inter-rater agreement. Discrepancies in quantitation of 21OHAb levels among different laboratories increased with increasing autoantibody levels. Conclusions: The quality of 21OHAb analytical procedures is mainly influenced by selection of cutoff value and correct handling of assay materials. A standardization program is needed to identify common standard sera and common measuring units.
  •  