SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1437 4331 ;pers:(Venge Per)"

Sökning: L773:1437 4331 > Venge Per

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Lindahl, Bertil, et al. (författare)
  • Evaluation of four sensitive troponin assays for risk assessment in acute coronary syndromes using a new clinically oriented approach for comparison of assays
  • 2013
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 51:9, s. 1859-1864
  • Tidskriftsartikel (refereegranskat)abstract
    • Background:Measurement of cardiac troponin T or I (cTnT; cTnI) is useful for risk prediction in acute coronary syndromes. The objective of the present study was to compare the prognostic capacity of four sensitive cardiac troponin assays using a new method for comparison.Methods:Cardiac troponin was analyzed in serum samples from 1335 patients with acute coronary syndrome using the Elecsys high sensitivity TnT (hs-cTnT), ARCHITECT STAT high sensitivity TnI (hs-cTnI), Access AccuTnI (Acc-cTnI) and Architect cTnI (Arc-cTnI) assays. All patients were followed for 30 days regarding death and acute myocardial infarction (AMI), and for 1 year regarding mortality.Results:By receiver operating characteristic (ROC) curve analyses, there were only minor differences in the area under the curves (AUC) between the assays. At a given sensitivity of 85% the hs-cTnT, Arc-cTnI and Acc-cTnI assays showed comparable specificities, while 90% or higher sensitivity was only possible to achieve with the hs-cTnT, hs-cTnI and Acc-cTnI assays. The highest odds ratios for death/AMI at 30 days and death at 1 year, respectively, were reached by cut-off levels yielding 95% sensitivity; these cut-off levels were below the respective 99th percentile levels.Conclusions:By the adoption of a new method for the comparison of cardiac troponin assays we showed that the hs-cTnT, hs-cTnI and Acc-cTnI assays had comparable prognostic properties, while the Arc-cTnI assay had inferior prognostic sensitivity.
  •  
2.
  • Savukoski, Tanja, et al. (författare)
  • Novel sensitive cardiac troponin I immunoassay free from troponin I-specific autoantibody interference
  • 2014
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 52:7, s. 1041-1048
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Cardiac troponins (cTnI and cTnT) are the recommended biomarkers of myocardial infarction. As cTn-specific autoantibodies (cTnAAb) can interfere with the cTn detection by state-of-the-art cTnI assays, our objective was to develop a sensitive cTnI immunoassay free from this analytical interference. Methods: The assay used antibody-coated spots containing three capture Mabs/Fabs directed against the N-terminus, midfragment and C-terminus of cTnI and a europium chelate-labeled tracer Mab against the C-terminus. Following a 3-h sample incubation and washing, cTnI was quantified by time-resolved fluorometry. Results: The limit of detection (LoD) was 2.9 ng/L and the assay was linear up to 50,000 ng/L. The total precision of 10% CV was not reached, but 20% CV was reached at 10 ng/L. Mean cTnI (10-50,000 ng/L) recoveries were 100% and 119% in three cTnAAb-positive and two cTnAAb-negative individuals, respectively, verifying the interference resistance of the antibody design used. On average, Architect hs-cTnI assay gave seven-fold higher cTnI concentrations than the new assay but the correlation between the assays was good (r=0.958). Of apparently healthy individuals (n=159), 18% had measurable cTnI values (>LoD) and 10% were cTnAAb-positive. The proportion of measurable cTnI values, however, was significantly higher in cTnAAb-positive individuals (13/16, median cTnI 8.5 ng/L) than in cTnAAb-negative individuals (15/143, median cTnI
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy