SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1473 5628 ;lar1:(gu)"

Sökning: L773:1473 5628 > Göteborgs universitet

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  • Gustafsson, Agnetha, et al. (författare)
  • Evaluation of various attenuation corrections in lung SPECT in healthy subjects
  • 2003
  • Ingår i: Nuclear Medicine Communications. - : Ovid Technologies (Wolters Kluwer Health). - 0143-3636 .- 1473-5628. ; 24:10, s. 1087-1095
  • Tidskriftsartikel (refereegranskat)abstract
    • The effect of increasingly more sophisticated attenuation correction methods on image homogeneity has been studied in seven healthy subjects. The subjects underwent computed tomography (CT), single photon emission computed tomography (SPECT) and transmission computed tomography (TCT) of the thorax region in the supine position. Density maps were obtained from the CT and TCT studies. Attenuation corrections were performed using five different methods: (1) uniform correction using only the body contour; (2) TCT based corrections using the average lung density; (3) TCT based corrections using the pixel density; (4) CT based corrections using average lung density; and (5) CT based corrections using the pixel density. The isolated attenuation effects were assessed on quotient images generated by the division of images obtained using various attenuation correction methods divided by the non-uniform attenuation correction based on CT pixel density (reference method). The homogeneity was calculated as the coefficient of variation of the quotient images (CVatt), showing the isolated attenuation effects. Values of CVatt were on average 12.8% without attenuation correction, 10.7% with the uniform correction, 8.1% using TCT map using the average lung density value and 4.8% using CT and average lung density corrections. There are considerable inhomogeneities in lung SPECT slices due to the attenuation effect. After attenuation correction the remaining inhomogeneity is considerable and cannot be explained by statistical noise and camera non-uniformity alone. ((C) 2003 Lippincott Williams Wilkins).
  •  
5.
  • Jakobson Mo, Susanna, 1968-, et al. (författare)
  • I-123-FP-Cit and I-123-IBZM SPECT uptake in a prospective normal material analysed with two different semiquantitative image evaluation tools
  • 2013
  • Ingår i: Nuclear Medicine Communications. - : Lippincott Williams & Wilkins. - 0143-3636 .- 1473-5628. ; 34:10, s. 978-989
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective The need for age-adjusted and/or sex-adjusted reference values in dopamine transporter (DAT) and dopamine D2 receptor (D2R) imaging with single-photon emission computed tomography (SPECT) in a longitudinal study of parkinsonian diseases was investigated. We used two different image evaluation tools with a cross-sectional and longitudinal statistical approach.Materials and methods Baseline DAT and/or D2R SPECT were performed in 51 healthy controls (HC), age-matched to patients in an ongoing prospective study on idiopathic parkinsonism. Twenty-four HC were re-examined after 3 years and 21 HC were examined again after 5 years. SPECT was performed with I-123-FP-Cit and I-123-IBZM on a two-headed hybrid gamma camera. Regions of interest and volumes of interest (VOIs) were used for image evaluation. A cross-sectional and longitudinal statistical analysis was carried out.Results Fewer sex-based differences and less age dependency were seen in DAT SPECT uptake ratios compared with D2R SPECT uptake ratios and when comparing uptake ratios obtained with regions of interest against those with VOIs. In the cross-sectional analysis, a significant age-dependent decline was seen in women in both DAT and D2R uptakes with the VOI method but not in men with either evaluation method. In the longitudinal dataset, both a slight decline and increase over time were seen in DAT uptake; however, a general pattern of decrease was seen in both men and women in D2R uptake.Conclusion The choice of the image evaluation method can influence the pattern of sex-based and age-related differences. The results speak for the use of age-stratified reference values for women, in particular when using a VOI method.
  •  
6.
  • Lyrdal, David, 1965, et al. (författare)
  • Evaluation of sorafenib treatment in metastatic renal cell carcinoma with 2-fluoro-2-deoxyglucose positron emission tomography and computed tomography.
  • 2009
  • Ingår i: Nuclear medicine communications. - 1473-5628. ; 30:7, s. 519-24
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: New potent tyrosine kinase inhibitors such as sorafenib are the most effective treatment for metastatic renal cell carcinoma (MRCC) today. In this study, we used [18F]-2-fluoro-2-deoxyglucose (FDG) with positron emission tomography (PET) combined with computed tomography (CT) to evaluate early effects of sorafenib in patients with MRCC. METHODS: Ten patients, eight males and two females, with a mean age of 61 years (49-72 years), with MRCC were enrolled. A total of 52 lesions, two to nine lesions/patient, out of which 39 were soft lesions, were evaluated. The [18F]FDG-PET/CT was performed before treatment and after 1-2 months. A region of interest (ROI) was identified including the lesions where the glucose uptake was measured, calculating the average value within the ROI and using the cerebellum as the reference. The same ROI was measured in the subsequent FDG-PET. The sum of the diameters was measured in CT according to the Response Evaluation Criteria in Solid Tumors (RECIST). Sorafenib was given 400 mg twice daily orally. RESULTS: After 1-2 months, the mean glucose uptake in all lesions decreased to 75% (32-105%) of initial values of ROI as measured by FDG-PET. The mean glucose uptake in soft lesions decreased to 71% (32-108%) and in skeletal lesions to 82% (53-101%). The sum of the diameters measured by CT decreased to 80% (57-94%) of the initial value in soft lesions according to the RECIST. CONCLUSION: An early decrease in the mean glucose uptake was found in both soft and skeletal lesions after treatment with sorafenib. FDG-PET thus seems to be advantageous, compared with RECIST evaluation, which is limited to soft lesions.
  •  
7.
  • Norberg, Pernilla, 1970-, et al. (författare)
  • Evaluation of reconstruction techniques for lung single photon emission tomography: a Monte Carlo study.
  • 2007
  • Ingår i: Nuclear medicine communications. - United States : Lippincott Williams & Wilkins. - 0143-3636 .- 1473-5628. ; 28:12, s. 929-36
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: In studies of the distribution of lung function, the image quality of lung single photon emission computed tomography (SPECT) is important and one factor influencing it is the reconstruction algorithm. AIM: To systematically evaluate ordered subsets expectation maximization (OSEM) and compare it with filtered back-projection (FBP) for lung SPECT with Tc. METHODS: The evaluation of the number of iterations used in OSEM was based on the image quality parameter contrast. The comparison between OSEM and FBP was based on trade-off plots between statistical noise and spatial resolution for different filter parameters, collimators and count-levels. A Monte Carlo technique was used to simulate SPECT studies of a digital thorax phantom containing two sets of activity: one with a homogeneous activity distribution within the lungs and the other with superposed high- and low-activity objects. Statistical noise in the reconstructed images was calculated as the coefficient of variation (CV) and spatial resolution as full width at half-maximum (FWHM). RESULTS: For the configuration studied, the OSEM reconstruction in combination with post-filtering should be used in lung SPECT studies with at least 60 MLEM equivalent iterations. Compared to FBP the spatial resolution was improved by about 1 mm. For a constant level of CV, a four-fold increase in count level resulted in an increased resolution of about 2 mm. Spatial resolution and cut-off frequency depends on what value of noise in the image is acceptable also increased by using a low-energy, high-resolution collimator for CV values above 3%. The choice of noise-reducing filter and cut-off frequency depends on what value of noise in the image is acceptable.
  •  
8.
  • Sadik, May, 1970, et al. (författare)
  • A new computer-based decision-support system for the interpretation of bone scans
  • 2006
  • Ingår i: Nucl Med Commun. - 0143-3636. ; 27:5, s. 417-423
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To develop a completely automated method, based on image processing techniques and artificial neural networks, for the interpretation of bone scans regarding the presence or absence of metastases. METHODS: A total of 200 patients, all of whom had the diagnosis of breast or prostate cancer and had undergone bone scintigraphy, were studied retrospectively. Whole-body images, anterior and posterior, were obtained after injection of 99mTc-methylene diphosphonate. The study material was randomly divided into a training group and a test group, with 100 patients in each group. The training group was used in the process of developing the image analysis techniques and to train the artificial neural networks. The test group was used to evaluate the automated method. The image processing techniques included algorithms for segmentation of the head, chest, spine, pelvis and bladder, automatic thresholding and detection of hot spots. Fourteen features from each examination were used as input to artificial neural networks trained to classify the images. The interpretations by an experienced physician were used as the 'gold standard'. RESULTS: The automated method correctly identified 28 of the 31 patients with metastases in the test group, i.e., a sensitivity of 90%. A false positive classification of metastases was made in 18 of the 69 patients not classified as having metastases by the experienced physician, resulting in a specificity of 74%. CONCLUSION: A completely automated method can be used to detect metastases in bone scans. Future developments in this field may lead to clinically valuable decision-support tools.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy