SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1473 5628 ;pers:(Källén Kristina)"

Sökning: L773:1473 5628 > Källén Kristina

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Källén, Kristina, et al. (författare)
  • Assessment of glioma viability by estimating 201Tl SPET tumour uptake volume
  • 1999
  • Ingår i: Nuclear Medicine Communications. - 1473-5628. ; 20:9, s. 837-844
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to develop a quantitative method to assess viable tumour based on post-operative 201Tl single photon emission tomography (SPET). We studied 15 patients with histologically defined highly malignant gliomas in the post-operative phase before initiation of adjuvant treatment. A 201Tl index was calculated in two ways: maximal counts versus mean counts within a region of interest (ROI). The tumour uptake volume (TUV) within the lesion was calculated from the number of voxels that had 201Tl uptake above a threshold calculated from the uptake on the contralateral side. The threshold was set at three levels: A = 1.4 times the mean 201Tl uptake in a three-dimensional reference ROI + 96.7% confidence interval (the TUV was corrected by subtraction of the volume in the reference ROI that had uptake above the threshold with compensation for unequal ROI sizes); B = 1.4 times the mean reference ROI + 99% confidence interval; and C = maximum 201Tl uptake in the reference ROI. The SPET results were compared with the tumour volumes calculated from CT scans. Thirteen tumours showed high post-operative 201Tl uptake. The 201Tl index was not significantly correlated with histological grade within the group of highly malignant gliomas. 201Tl SPET tumour uptake volume method B was highly significantly correlated with CT estimated tumour volume. In conclusion, the measurement of post-operative 201Tl SPET tumour uptake volume demonstrates metabolically active glioma tissue and is an alternative method for the monitoring of glioma treatment response.
  •  
2.
  • Källén, Kristina, et al. (författare)
  • Quantitative 201Tl SPET imaging in the follow-up of treatment for brain tumour: a sensitive tool for the early identification of response to chemotherapy?
  • 2000
  • Ingår i: Nuclear Medicine Communications. - 1473-5628. ; 21:3, s. 259-267
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to establish if repeated quantitative 201Tl SPET scanning during follow-up of astrocytoma therapy can provide information that is relevant for clinical management. Sixteen consecutive patients, with histopathologically verified highly malignant astrocytoma, were followed during PCV chemotherapy. Imaging with 201Tl SPET and CT was performed repeatedly over 8-16 weeks until treatment discontinuation, with a maximum follow-up of 74 weeks. Tumour uptake volume (TUV), a measure of metabolically active tumour tissue, was calculated from the SPET images. The reliability of early identification of treatment failure, defined as > 25% tumour volume increase, following one course (week 8) and three courses (week 24) of chemotherapy, was calculated for the two imaging methods. 201Tl SPET positive patients (> 25% tumour volume increase) were compared with 201Tl SPET negative patients in terms of time to treatment discontinuation (TTD) and survival time (ST). The patients were followed with a total of 59 SPET examinations, and treatment was continued for a median 27 weeks (range 16-78 weeks). The comparative reliability of SPET and CT showed the highest sensitivity and accuracy for SPET in the early identification of astrocytoma treatment failure at the week 24 assessment. Patients with positive 201Tl SPET after three courses of chemotherapy had a significantly reduced TTD (P = 0.040) but not significantly reduced ST. Of the ten patients who received concomitant radiation and chemotherapy, five had a small (0-10 ml) TUV at the week 24 assessment. Patients with a TUV > 10 ml at this assessment had a shorter TTD (P = 0.016) and a reduced ST (P = 0.024) compared to patients with a TUV < 10 ml. In conclusion, the assessment of progressive disease by quantitative 201Tl SPET appears to provide information on treatment response, earlier and with a higher reliability than CT. Repeated 201Tl SPET scanning during follow-up of astrocytoma treatment is an alternative tool for the early identification of treatment failure.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Rosén, Ingmar (2)
Holtås, Stig (2)
Ryding, Erik (2)
Geijer, Bo (2)
Andersson, A. M. (1)
visa fler...
Andersson, Ann Margr ... (1)
Malmstrom, Per (1)
visa färre...
Lärosäte
Lunds universitet (2)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy