SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1473 5628 ;pers:(Riklund Katrine)"

Sökning: L773:1473 5628 > Riklund Katrine

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Jakobson Mo, Susanna, 1968-, et al. (författare)
  • I-123-FP-Cit and I-123-IBZM SPECT uptake in a prospective normal material analysed with two different semiquantitative image evaluation tools
  • 2013
  • Ingår i: Nuclear Medicine Communications. - : Lippincott Williams & Wilkins. - 0143-3636 .- 1473-5628. ; 34:10, s. 978-989
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective The need for age-adjusted and/or sex-adjusted reference values in dopamine transporter (DAT) and dopamine D2 receptor (D2R) imaging with single-photon emission computed tomography (SPECT) in a longitudinal study of parkinsonian diseases was investigated. We used two different image evaluation tools with a cross-sectional and longitudinal statistical approach.Materials and methods Baseline DAT and/or D2R SPECT were performed in 51 healthy controls (HC), age-matched to patients in an ongoing prospective study on idiopathic parkinsonism. Twenty-four HC were re-examined after 3 years and 21 HC were examined again after 5 years. SPECT was performed with I-123-FP-Cit and I-123-IBZM on a two-headed hybrid gamma camera. Regions of interest and volumes of interest (VOIs) were used for image evaluation. A cross-sectional and longitudinal statistical analysis was carried out.Results Fewer sex-based differences and less age dependency were seen in DAT SPECT uptake ratios compared with D2R SPECT uptake ratios and when comparing uptake ratios obtained with regions of interest against those with VOIs. In the cross-sectional analysis, a significant age-dependent decline was seen in women in both DAT and D2R uptakes with the VOI method but not in men with either evaluation method. In the longitudinal dataset, both a slight decline and increase over time were seen in DAT uptake; however, a general pattern of decrease was seen in both men and women in D2R uptake.Conclusion The choice of the image evaluation method can influence the pattern of sex-based and age-related differences. The results speak for the use of age-stratified reference values for women, in particular when using a VOI method.
  •  
2.
  • Jakobson Mo, Susanna, et al. (författare)
  • VNTR polymorphism in the SLC6A3 gene does not influence dopamine transporter availability measured by [18F]FE-PE2I PET or [123I]FP-Cit SPECT
  • 2022
  • Ingår i: Nuclear medicine communications. - : Wolters Kluwer. - 0143-3636 .- 1473-5628. ; 43:3, s. 247-255
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To investigate the potential impact of polymorphism in the 3'-untranslated region (3'UTR) of the SLC6A3 gene (DAT1) on normal variation in dopamine transporter (DAT) imaging with [18F]FE-PE2I PET and [123I]FP-Cit SPECT.METHODS: Thirty-six individuals (mean age 70.4±5.4 years) with normal [18F]FE-PE2I PET and [123I]FP-Cit SPECT were genotyped for variable number of tandem repeats (VNTR) in the 3′UTR of the DAT1 gene. The DAT-availability in the caudate and putamen as measured with [18F]FE-PE2I PET and [123I]FP-Cit SPECT, as well as in the substantia nigra with [18F]FE-PE2I PET were compared between the participants carrying one or two 9-repeat alleles (i.e. 9R+10R or 9R+9R; 47%) and the participants without a 9R allele (i.e. 10R+10R or 10R+11R; 53%). Nonparametric tests, linear regression analysis and mixed model analysis were used to assess any statistical difference in measured DAT availability between the two allele groups.RESULTS: The measured DAT-availability in PET- and SPECT-imaging tended to be slightly higher in the 9R-group; however, the difference did not reach statistical significance in either the caudate or the putamen or the substantia nigra. Instead, age did have a significant effect on the DAT level (P < 0.05) notwithstanding the genotype.CONCLUSION: No significant effect of DAT1-genotype was detectable in imaging with [18F]FE-PE2I PET or [123I]FP-Cit, instead, age accounted for the normal variation in DAT-PET and DAT-SPECT.
  •  
3.
  • Larsson, Anne, et al. (författare)
  • A method for attenuation and scatter correction of brain SPECT based on computed tomography images
  • 2003
  • Ingår i: Nuclear medicine communications. - 0143-3636 .- 1473-5628. ; 24:4, s. 411-420
  • Tidskriftsartikel (refereegranskat)abstract
    • A method for attenuation and scatter correction of brain single photon emission computed tomography (SPECT) is described where computed tomography (CT) images of the brain are used for the calculation of attenuation maps. The method is evaluated for the substance 99mTc hexamethylpropylene amine oxime. A transmission dependent scatter correction is utilized and is based on ray sums calculated through the attenuation map. A method based on external markers is used to align the SPECT and CT image volumes. The markers need only to be present during the SPECT acquisition since the corresponding landmarks can be found without markers on the CT images. The mismatching has been investigated for five patients who have undergone both a CT examination and a SPECT examination with markers. Twelve individuals from the staff have pointed out the landmarks on the CT images, with an average standard deviation of 3.4 mm. Reconstructions with an attenuation map shifted the corresponding 95% confidence interval have been performed to obtain an estimation of the quantitative uncertainty caused by the mismatching, and quantitative errors of up to 6.3% have been measured. At present the method is probably most useful when groups of patients are studied.
  •  
4.
  • Sandgren, Kristina, et al. (författare)
  • Histopathology-validated lesion detection rates of clinically significant prostate cancer with mpMRI, [68Ga]PSMA-11-PET and [11C]Acetate-PET
  • 2023
  • Ingår i: Nuclear medicine communications. - : Lippincott Williams & Wilkins. - 0143-3636 .- 1473-5628. ; 44:11, s. 997-1004
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: PET/CT and multiparametric MRI (mpMRI) are important diagnostic tools in clinically significant prostate cancer (csPC). The aim of this study was to compare csPC detection rates with [68Ga]PSMA-11-PET (PSMA)-PET, [11C] Acetate (ACE)-PET, and mpMRI with histopathology as reference, to identify the most suitable imaging modalities for subsequent hybrid imaging. An additional aim was to compare inter-reader variability to assess reproducibility.Methods: During 2016–2019, all study participants were examined with PSMA-PET/mpMRI and ACE-PET/CT prior to radical prostatectomy. PSMA-PET, ACE-PET and mpMRI were evaluated separately by two observers, and were compared with histopathology-defined csPC. Statistical analyses included two-sided McNemar test and index of specific agreement.Results: Fifty-five study participants were included, with 130 histopathological intraprostatic lesions >0.05 cc. Of these, 32% (42/130) were classified as csPC with ISUP grade ≥2 and volume >0.5 cc. PSMA-PET and mpMRI showed no difference in performance (P = 0.48), with mean csPC detection rate of 70% (29.5/42) and 74% (31/42), respectively, while with ACE-PET the mean csPC detection rate was 37% (15.5/42). Interobserver agreement was higher with PSMA-PET compared to mpMRI [79% (26/33) vs 67% (24/38)]. Including all detected lesions from each pair of observers, the detection rate increased to 90% (38/42) with mpMRI, and 79% (33/42) with PSMA-PET.Conclusion: PSMA-PET and mpMRI showed high csPC detection rates and superior performance compared to ACE-PET. The interobserver agreement indicates higher reproducibility with PSMA-PET. The combined result of all observers in both PSMA-PET and mpMRI showed the highest detection rate, suggesting an added value of a hybrid imaging approach.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy