SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Extended search

L773:1532 2092
 

Search: L773:1532 2092 > Stockholm University > Hypersensitivity to...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Hypersensitivity to material and environmental burden as a possible cause of late complications of cardiac implantable electronic devices

Manousek, Jan (author)
Andrsova, Irena (author)
Stejskal, Vera (author)
Stockholms universitet,Institutionen för molekylär biovetenskap, Wenner-Grens institut,Masaryk Universit, Czech Republic
show more...
Vlasinova, Jitka (author)
Sepsi, Milan (author)
Kuta, Jan (author)
Klanova, Jana (author)
Mazik, Michal (author)
Jarkovsky, Jiri (author)
Snajdrova, Lenka (author)
Benesova, Klara (author)
Novotny, Tomas (author)
Zadakova, Andrea (author)
Spinar, Jindrich (author)
show less...
 (creator_code:org_t)
2017-08-02
2018
English.
In: Europace. - : Oxford University Press (OUP). - 1099-5129 .- 1532-2092. ; 20:9, s. e140-e147
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • AimsTo evaluate whether patients with late complications of pacemakers or implantable cardioverter-defibrillators have hypersensitivity reactions to some of the materials used in generators or in electrodes, or to environmental metal burden.Methods and resultsThe cohort consisted of 20 men and 4 women (mean age: 62.3 +/- 17.2 years) who had a history of late complications of implanted devices. The control group involved 25 men and 8 women (mean age: 64.6 +/- 14.0 years) who had comparable devices, but no history of late complications. Lymphocyte transformation test was used to evaluate hypersensitivity to eight metal pollutants (antimony, manganese, mercury, molybdenum, nickel, platinum, tin, and titanium) selected by results of questionnaires on environmental burden, and by material analysis of generators and electrode surfaces. Exposures to metal pollutants were approximately the same in patients and in controls. Titanium alloy used in generators contained at least 99.32% of titanium and trace levels of other metals; higher levels of tin and platinum were detected in electrode surfaces. Hypersensitivity reactions to mercury and tin were significantly more frequent in patients than in controls (patients and controls: mercury: 68.2 and 31.1%, respectively; P = 0.022; tin: 25.0 and 3.2%, respectively; P = 0.035). In contrast, hypersensitivity to manganese was significantly more frequent in controls than in patients (patients and controls: 13.6 and 50.0%, respectively; P = 0.008).ConclusionOur findings suggest a possible relation between hypersensitivity to metals used in implantable devices or to environmental metal burden and the occurrence of their late complications.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Keyword

Pacemaker
Implantable cardioverter-defibrillator
Late complication
Metal pollutants
Delayed-type hypersensitivity
Lymphocyte transformation test

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

  • Europace (Search for host publication in LIBRIS)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close