SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1559 7016 ;lar1:(su)"

Sökning: L773:1559 7016 > Stockholms universitet

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Alakurtti, Kati, et al. (författare)
  • Long-term test-retest reliability of striatal and extrastriatal dopamine D-2/3 receptor binding : study with [C-11]raclopride and high-resolution PET
  • 2015
  • Ingår i: Journal of Cerebral Blood Flow and Metabolism. - : SAGE Publications. - 0271-678X .- 1559-7016. ; 35:7, s. 1199-1205
  • Tidskriftsartikel (refereegranskat)abstract
    • We measured the long-term test-retest reliability of [C-11]raclopride binding in striatal subregions, the thalamus and the cortex using the bolus-plus-infusion method and a high-resolution positron emission scanner. Seven healthy male volunteers underwent two positron emission tomography (PET) [C-11]raclopride assessments, with a 5-week retest interval. D-2/3 receptor availability was quantified as binding potential using the simplified reference tissue model. Absolute variability (VAR) and intraclass correlation coefficient (ICC) values indicated very good reproducibility for the striatum and were 4.5%/0.82, 3.9%/0.83, and 3.9%/0.82, for the caudate nucleus, putamen, and ventral striatum, respectively. Thalamic reliability was also very good, with VAR of 3.7% and ICC of 0.92. Test-retest data for cortical areas showed good to moderate reproducibility (6.1% to 13.1%). Our results are in line with previous test-retest studies of [C-11]raclopride binding in the striatum. A novel finding is the relatively low variability of [C-11]raclopride binding, providing suggestive evidence that extrastriatal D-2/3 binding can be studied in vivo with [C-11]raclopride PET to be verified in future studies.
  •  
2.
  • Karalija, Nina, 1984-, et al. (författare)
  • High long-term test-retest reliability for extrastriatal C-11-raclopride binding in healthy older adults
  • 2020
  • Ingår i: Journal of Cerebral Blood Flow and Metabolism. - : Sage Publications. - 0271-678X .- 1559-7016. ; 40:9, s. 1859-1868
  • Tidskriftsartikel (refereegranskat)abstract
    • In vivo dopamine D2-receptor availability is frequently assessed with C-11-raclopride and positron emission tomography. Due to low signal-to-noise ratios for C-11-raclopride in areas with low D2 receptor densities, the ligand has been considered unreliable for measurements outside the dopamine-dense striatum. Intriguingly, recent studies show that extrastriatal C-11-raclopride binding potential (BPND) values are (i) reliably higher than in the cerebellum (where D2-receptor levels are negligible), (ii) correlate with behavior in the expected direction, and (iii) showed good test-retest reliability in a sample of younger adults. The present work demonstrates high seven-month test-retest reliability of striatal and extrastriatal C-11-raclopride BPND values in healthy, older adults (n = 27, age: 64-78 years). Mean C-11-raclopride BPND values were stable between test sessions in subcortical nuclei, and in frontal and temporal cortices (p > 0.05). Across all structures analyzed, intraclass correlation coefficients were high (0.85-0.96), absolute variability was low (mean: 4-8%), and coefficients of variance ranged between 9 and 25%. Furthermore, regional C-11-raclopride BPND values correlated with previously determined F-18-fallypride BPND values (rho = 0.97 and 0.92 in correlations with and without striatal values, respectively, p < 0.01) and postmortem determined D2-receptor densities (including striatum: rho = 0.92; p < 0.001; excluding striatum: rho = 0.75; p = 0.067). These observations suggest that extrastriatal C-11-raclopride measurements represent a true D2 signal.
  •  
3.
  • Schain, Martin, et al. (författare)
  • Arterial input function derived from pairwise correlations between PET-image voxels
  • 2013
  • Ingår i: Journal of Cerebral Blood Flow and Metabolism. - : Nature Publishing Group. - 0271-678X .- 1559-7016. ; 33:7, s. 1058-1065
  • Tidskriftsartikel (refereegranskat)abstract
    • A metabolite corrected arterial input function is a prerequisite for quantification of positron emission tomography (PET) data by compartmental analysis. This quantitative approach is also necessary for radioligands without suitable reference regions in brain. The measurement is laborious and requires cannulation of a peripheral artery, a procedure that can be associated with patient discomfort and potential adverse events. A non invasive procedure for obtaining the arterial input function is thus preferable. In this study, we present a novel method to obtain image-derived input functions (IDIFs). The method is based on calculation of the Pearson correlation coefficient between the time-activity curves of voxel pairs in the PET image to localize voxels displaying blood-like behavior. The method was evaluated using data obtained in human studies with the radioligands [11C]flumazenil and [11C]AZ10419369, and its performance was compared with three previously published methods. The distribution volumes (VT) obtained using IDIFs were compared with those obtained using traditional arterial measurements. Overall, the agreement in VT was good (~3% difference) for input functions obtained using the pairwise correlation approach. This approach performed similarly or even better than the other methods, and could be considered in applied clinical studies. Applications to other radioligands are needed for further verification.
  •  
4.
  • Vikner, Tomas, et al. (författare)
  • Cerebral arterial pulsatility is linked to hippocampal microvascular function and episodic memory in healthy older adults
  • 2021
  • Ingår i: Journal of Cerebral Blood Flow and Metabolism. - : Sage Publications. - 0271-678X .- 1559-7016. ; 41:7, s. 1778-1790
  • Tidskriftsartikel (refereegranskat)abstract
    • Microvascular damage in the hippocampus is emerging as a central cause of cognitive decline and dementia in aging. This could be a consequence of age-related decreases in vascular elasticity, exposing hippocampal capillaries to excessive cardiac-related pulsatile flow that disrupts the blood-brain barrier and the neurovascular unit. Previous studies have found altered intracranial hemodynamics in cognitive impairment and dementia, as well as negative associations between pulsatility and hippocampal volume. However, evidence linking features of the cerebral arterial flow waveform to hippocampal function is lacking. We used a high-resolution 4D flow MRI approach to estimate global representations of the time-resolved flow waveform in distal cortical arteries and in proximal arteries feeding the brain in healthy older adults. Waveform-based clustering revealed a group of individuals featuring steep systolic onset and high amplitude that had poorer hippocampus-sensitive episodic memory (p = 0.003), lower whole-brain perfusion (p = 0.001), and weaker microvascular low-frequency oscillations in the hippocampus (p = 0.035) and parahippocampal gyrus (p = 0.005), potentially indicating compromised neurovascular unit integrity. Our findings suggest that aberrant hemodynamic forces contribute to cerebral microvascular and hippocampal dysfunction in aging.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy