1.
  • Adjeiwaah, Mary, 1980-, et al. (författare)
  • Dosimetric Impact of MRI Distortions : A Study on Head and Neck Cancers
  • 2019
  • Ingår i: International Journal of Radiation Oncology, Biology, Physics. - : Elsevier. - 0360-3016 .- 1879-355X. ; 103:4, s. 994-1003
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To evaluate the effect of magnetic resonance (MR) imaging (MRI) geometric distortions on head and neck radiation therapy treatment planning (RTP) for an MRI-only RTP. We also assessed the potential benefits of patient-specific shimming to reduce the magnitude of MR distortions for a 3-T scanner.Methods and Materials: Using an in-house Matlab algorithm, shimming within entire imaging volumes and user-defined regions of interest were simulated. We deformed 21 patient computed tomography (CT) images with MR distortion fields (gradient nonlinearity and patient-induced susceptibility effects) to create distorted CT (dCT) images using bandwidths of 122 and 488 Hz/mm at 3 T. Field parameters from volumetric modulated arc therapy plans initially optimized on dCT data sets were transferred to CT data to compute a new plan. Both plans were compared to determine the impact of distortions on dose distributions.Results: Shimming across entire patient volumes decreased the percentage of voxels with distortions of more than 2 mm from 15.4% to 2.0%. Using the user-defined region of interest (ROI) shimming strategy, (here the Planning target volume (PTV) was the chosen ROI volume) led to increased geometric for volumes outside the PTV, as such voxels within the spinal cord with geometric shifts above 2 mm increased from 11.5% to 32.3%. The worst phantom-measured residual system distortions after 3-dimensional gradient nonlinearity correction within a radial distance of 200 mm from the isocenter was 2.17 mm. For all patients, voxels with distortion shifts of more than 2 mm resulting from patient-induced susceptibility effects were 15.4% and 0.0% using bandwidths of 122 Hz/mm and 488 Hz/mm at 3 T. Dose differences between dCT and CT treatment plans in D-50 at the planning target volume were 0.4% +/- 0.6% and 0.3% +/- 0.5% at 122 and 488 Hz/mm, respectively.Conclusions: The overall effect of MRI geometric distortions on data used for RTP was minimal. Shimming over entire imaging volumes decreased distortions, but user-defined subvolume shimming introduced significant errors in nearby organs and should probably be avoided.
  •  
2.
  • Adjeiwaah, Mary, et al. (författare)
  • Quantifying the Effect of 3T Magnetic Resonance Imaging Residual System Distortions and Patient-Induced Susceptibility Distortions on Radiation Therapy Treatment Planning for Prostate Cancer
  • 2018
  • Ingår i: International Journal of Radiation Oncology, Biology, Physics. - : Elsevier. - 0360-3016 .- 1879-355X. ; 100:2, s. 317-324
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To investigate the effect of magnetic resonance system- and patient-induced susceptibility distortions from a 3T scanner on dose distributions for prostate cancers.Methods and Materials: Combined displacement fields from the residual system and patient-induced susceptibility distortions were used to distort 17 prostate patient CT images. VMAT dose plans were initially optimized on distorted CT images and the plan parameters transferred to the original patient CT images to calculate a new dose distribution.Results: Maximum residual mean distortions of 3.19 mm at a radial distance of 25 cm and maximum mean patient-induced susceptibility shifts of 5.8 mm were found using the lowest bandwidth of 122 Hz per pixel. There was a dose difference of <0.5% between distorted and undistorted treatment plans. The 90% confidence intervals of the mean difference between the dCT and CT treatment plans were all within an equivalence interval of (−0.5, 0.5) for all investigated plan quality measures.Conclusions: Patient-induced susceptibility distortions at high field strengths in closed bore magnetic resonance scanners are larger than residual system distortions after using vendor-supplied 3-dimensional correction for the delineated regions studied. However, errors in dose due to disturbed patient outline and shifts caused by patient-induced susceptibility effects are below 0.5%.
  •  
3.
  • Jonsson, Joakim H, et al. (författare)
  • Internal fiducial markers and susceptibility effects in MRI : simulation and measurement of spatial accuracy
  • 2012
  • Ingår i: International Journal of Radiation Oncology, Biology, Physics. - : Elsevier BV. - 0360-3016 .- 1879-355X. ; 82:5, s. 1612-1618
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: It is well-known that magnetic resonance imaging (MRI) is preferable to computed tomography (CT) in radiotherapy target delineation. To benefit from this, there are two options available: transferring the MRI delineated target volume to the planning CT or performing the treatment planning directly on the MRI study. A precondition for excluding the CT study is the possibility to define internal structures visible on both the planning MRI and on the images used to position the patient at treatment. In prostate cancer radiotherapy, internal gold markers are commonly used, and they are visible on CT, MRI, x-ray, and portal images. The depiction of the markers in MRI are, however, dependent on their shape and orientation relative the main magnetic field because of susceptibility effects. In the present work, these effects are investigated and quantified using both simulations and phantom measurements.METHODS AND MATERIALS: Software that simulated the magnetic field distortions around user defined geometries of variable susceptibilities was constructed. These magnetic field perturbation maps were then reconstructed to images that were evaluated. The simulation software was validated through phantom measurements of four commercially available gold markers of different shapes and one in-house gold marker.RESULTS: Both simulations and phantom measurements revealed small position deviations of the imaged marker positions relative the actual marker positions (<1 mm).CONCLUSION: Cylindrical gold markers can be used as internal fiducial markers in MRI.
  •  
4.
  • Karlsson, Mikael, et al. (författare)
  • Dedicated magnetic resonance imaging in the radiotherapy clinic
  • 2009
  • Ingår i: International journal of radiation oncology, biology, physics. - : Elsevier BV. - 1879-355X .- 0360-3016. ; 74:2, s. 644-651
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To introduce a novel technology arrangement in an integrated environment and outline the logistics model needed to incorporate dedicated magnetic resonance (MR) imaging in the radiotherapy workflow. An initial attempt was made to analyze the value and feasibility of MR-only imaging compared to computed tomography (CT) imaging, testing the assumption that MR is a better choice for target and healthy tissue delineation in radiotherapy. METHODS AND MATERIALS: A 1.5-T MR unit with a 70-cm-bore size was installed close to a linear accelerator, and a special trolley was developed for transporting patients who were fixated in advance between the MR unit and the accelerator. New MR-based workflow procedures were developed and evaluated. RESULTS: MR-only treatment planning has been facilitated, thus avoiding all registration errors between CT and MR scans, but several new aspects of MR imaging must be considered. Electron density information must be obtained by other methods. Generation of digitally reconstructed radiographs (DRR) for x-ray setup verification is not straight forward, and reliable corrections of geometrical distortions must be applied. The feasibility of MR imaging virtual simulation has been demonstrated, but a key challenge to overcome is correct determination of the skeleton, which is often needed for the traditional approach of beam modeling. The trolley solution allows for a highly precise setup for soft tissue tumors without the invasive handling of radiopaque markers. CONCLUSIONS: The new logistics model with an integrated MR unit is efficient and will allow for improved tumor definition and geometrical precision without a significant loss of dosimetric accuracy. The most significant development needed is improved bone imaging.
  •  
5.
  • Persson, Emilia, et al. (författare)
  • MR-OPERA : A Multicenter/Multivendor Validation of Magnetic Resonance Imaging-Only Prostate Treatment Planning Using Synthetic Computed Tomography Images
  • 2017
  • Ingår i: International Journal of Radiation Oncology, Biology, Physics. - : ELSEVIER SCIENCE INC. - 0360-3016 .- 1879-355X. ; 99:3, s. 692-700
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To validate the dosimetric accuracy and clinical robustness of a commercially available software for magnetic resonance (MR) to synthetic computed tomography (sCT) conversion, in an MR imaginge-only workflow for 170 prostate cancer patients.Methods and Materials: The 4 participating centers had MriPlanner (Spectronic Medical), an atlas-based sCT generation software, installed as a cloud-based service. A T2-weighted MR sequence, covering the body contour, was added to the clinical protocol. The MR images were sent from the MR scanner workstation to theMriPlanner platform. The sCT was automatically returned to the treatment planning system. Four MR scanners and 2 magnetic field strengths were included in the study. For each patient, a CT-treatment plan was created and approved according to clinical practice. The sCT was rigidly registered to the CT, and the clinical treatment plan was recalculated on the sCT. The dose distributions from the CT plan and the sCT plan were compared according to a set of dose-volume histogram parameters and gamma evaluation. Treatment techniques included volumetric modulated arc therapy, intensity modulated radiation therapy, and conventional treatment using 2 treatment planning systems and different dose calculation algorithms.Results: The overall (multicenter/multivendor) mean dose differences between sCT and CT dose distributions were below 0.3% for all evaluated organs and targets. Gamma evaluation showed a mean pass rate of 99.12% (0.63%, 1 SD) in the complete body volume and 99.97% (0.13%, 1 SD) in the planning target volume using a 2%/ 2-mm global gamma criteria.Conclusions: Results of the study show that the sCT conversion method can be used clinically, with minimal differences between sCT and CT dose distributions for target and relevant organs at risk. The small differences seen are consistent between centers, indicating that an MR imagingeonly workflow using MriPlanner is robust for a variety of field strengths, vendors, and treatment techniques.
  •  