SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1996 1073 ;pers:(Malmquist Anders)"

Sökning: L773:1996 1073 > Malmquist Anders

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Wegener, Moritz, et al. (författare)
  • 3E-Analysis of a Bio-Solar CCHP System for theAndaman Islands, India—A Case Study
  • 2019
  • Ingår i: Energies. - Basel, Switzerland : MDPI. - 1996-1073. ; 12:6
  • Tidskriftsartikel (refereegranskat)abstract
    • Energy services are especially expensive on remote islands due to longer and more unstable fuel supply chains. In this paper, different renewable energy systems utilizing locally available biomass and solar energy are proposed as alternatives for a hotel resort on Neil Island, India. Based on local demand data, commercial information, and scientific literature, four cases are modelled with the simulation software HOMER and their economic, energetic, as well as ecological (3E) performances are compared. The robustness of each case configuration is tested with a sensitivity analysis. The results show that a biomass-based, solar-assisted combined cooling, heating, and power (CCHP) system offers an economic saving potential of more than 500,000 USD over twenty years and could decrease CO2 emissions by 365 t per year. When not applying CCHP measures, system performance is significantly worsened. A solar and battery-assisted diesel generator system shows similar economic outcomes as the CCHP system but worse ecological performance. Implementing the biomass-based CCHP system could improve the ecological footprint of the island, substantially decrease expenditure for the hotel owner, and generate a new source of income for surrounding farmers through biomass selling.
  •  
2.
  • Ghaem Sigarchian, Sara, 1979-, et al. (författare)
  • Design Optimization of a Complex Polygeneration System for a Hospital
  • 2018
  • Ingår i: Energies. - : MDPI. - 1996-1073. ; 11:5
  • Tidskriftsartikel (refereegranskat)abstract
    • Small-scale decentralized polygeneration systems have several energetic, economic and environmental benefits. However, using multiple energy sources and providing multiple energy services can lead to complicated studies which require advanced optimization techniques for determining optimal solutions. Furthermore, several parameters can influence the design and performance of a polygeneration system. In this study, the effects of heat load, renewable generation and storage units on the optimal design and performance of a polygeneration system for a hypothetical hospital located in northern Italy are investigated. The polygeneration system shows higher performance compared to the reference system, which is based on the separate generation of heat and power. It reduces fuel consumption by 14-32%, CO2 emissions by 10-29% and annualized total cost by 7-19%, for various studied scenarios. The avoided fuel and electricity purchase of the polygeneration system has a positive impact on the economy. This, together with the environmental and energetic benefits if the renewable generation and use of storage devices, indicate the viability and competitiveness of the system.
  •  
3.
  • Ghaem Sigarchian, Sara, et al. (författare)
  • Design optimization of a small-scale polygeneration energy system in different climate zones in Iran
  • 2018
  • Ingår i: Energies. - : MDPI AG. - 1996-1073. ; 11:5
  • Tidskriftsartikel (refereegranskat)abstract
    • Design and performance of polygeneration energy systems are highly influenced by several variables, including the climate zone, which can affect the load profile as well as the availability of renewable energy sources. To investigate the effects, in this study, the design of a polygeneration system for identical residential buildings that are located in three different climate zones in Iran has been investigated. To perform the study, a model has previously developed by the author is used. The performance of the polygeneration system in terms of energy, economy and environment were compared to each other. The results show significant energetic and environmental benefits of the implementation of polygeneration systems in Iran, especially in the building that is located in a hot climate, with a high cooling demand and a low heating demand. Optimal polygeneration system for an identical building has achieved a 27% carbon dioxide emission reduction in the cold climate, while this value is around 41% in the hot climate. However, when considering the price of electricity and gas in the current energy market in Iran, none of the systems are feasible and financial support mechanisms or other incentives are required to promote the application of decentralized polygeneration energy systems.
  •  
4.
  • Villarroel-Schneider, Johnny, et al. (författare)
  • Performance Analysis of a Small-Scale Biogas-Based Trigeneration Plant : An Absorption Refrigeration System Integrated to an Externally Fired Microturbine
  • 2019
  • Ingår i: Energies. - : MDPI AG. - 1996-1073. ; 12:20
  • Tidskriftsartikel (refereegranskat)abstract
    • Trigeneration or combined cooling, heat and power (CCHP) systems fueled by raw biogas can be an interesting alternative for supplying electricity and thermal services in remote rural areas where biogas can be produced without requiring sophisticated equipment. In this sense, this study considers a performance analysis of a novel small-scale CCHP system where a biogas-fired, 5 kW(el) externally fired microturbine (EFMT), an absorption refrigeration system (ARS) and heat exchangers are integrated for supplying electricity, refrigeration and hot water demanded by Bolivian small dairy farms. The CCHP solution presents two cases, current and nominal states, in which experimental and design data of the EFMT performance were considered, respectively. The primary energy/exergy rate was used as a performance indicator. The proposed cases show better energy performances than those of reference fossil fuel-based energy solutions (where energy services are produced separately) allowing savings in primary energy utilization of up to 31%. Furthermore, improvements in electric efficiency of the EFMT and coefficient of performance (COP) of the ARS, identified as key variables of the system, allow primary energy savings of up to 37%. However, to achieve these values in real conditions, more research and development of the technologies involved is required, especially for the EFMT.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy