SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1996 1073 ;pers:(Thern Marcus)"

Sökning: L773:1996 1073 > Thern Marcus

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bahrami, Saeed, et al. (författare)
  • Improving the Transient Performance of the Gas Turbine by Steam Injection during Frequency Dips
  • 2013
  • Ingår i: Energies. - : MDPI AG. - 1996-1073. ; 6:10, s. 5283-5296
  • Tidskriftsartikel (refereegranskat)abstract
    • Single-shaft gas turbines are sensitive to frequency changes which might affect the grid stability during large frequency drops. This paper presents a new control system that uses steam injection as an auxiliary input to improve the transient performance of the gas turbine during frequency drops. Steam injection is beneficial because it reduces the peak temperature in the combustion chamber and augments the output power by increasing the mass flow through the turbine. The use of this auxiliary input is based on the event-based control approach. It means that during the frequency drop, the controller exploits the steam injection to help the main control loop recover the frequency and when the frequency reaches its predefined value, the system will return to its normal operation. The performance of the proposed control algorithm is investigated under different scenarios and the results show that the application of steam injection improves the performance of the regular control algorithm significantly, especially near full load condition.
  •  
2.
  • Bahrami, Saeed, et al. (författare)
  • Performance Comparison between Steam Injected Gas Turbine and Combined Cycle during Frequency Drops
  • 2015
  • Ingår i: Energies. - : MDPI AG. - 1996-1073. ; 8:8, s. 7582-7592
  • Tidskriftsartikel (refereegranskat)abstract
    • Single-shaft gas turbine and its cycles are sensitive to frequency drops and, therefore, sudden change loads or large frequency dips might affect their stability. This phenomenon is related to the reduction of the air mass flow passing through the machine during the frequency dips, which might lead to an interaction between governor and temperature control loop. In this paper, the performance of the combined cycle and steam-injected gas turbine are studied during frequency dips and transient maneuvers. For this purpose, two similar units are developed based on these cycles and their performances are studied in different scenarios. The simulation results show that the steam injected gas turbine has a better performance during frequency drops and it can handle relatively larger change loads.
  •  
3.
  • Baldi, Francesco, 1986, et al. (författare)
  • Energy and exergy analysis of a cruise ship
  • 2018
  • Ingår i: Energies. - Basel, Switzerland : MDPI. - 1996-1073. ; 11:10, s. 1-41
  • Tidskriftsartikel (refereegranskat)abstract
    • In recent years, the International Maritime Organization agreed on aiming to reduce shipping’s greenhouse gas emissions by 50% with respect to 2009 levels. Meanwhile, cruise ship tourism is growing at a fast pace, making the challenge of achieving this goal even harder. The complexity of the energy system of these ships makes them of particular interest from an energy systems perspective. To illustrate this, we analyzed the energy and exergy flow rates of a cruise ship sailing in the Baltic Sea based on measurements from one year of the ship’s operations. The energy analysis allows identifying propulsion as the main energy user (46% of the total) followed by heat (27%) and electric power (27%) generation; the exergy analysis allowed instead identifying the main inefficiencies of the system: while exergy is primarily destroyed in all processes involving combustion (76% of the total), the other main causes of exergy destruction are the turbochargers, the heat recovery steam generators, the steam heaters, the preheater in the accommodation heating systems, the sea water coolers, and the electric generators; the main exergy losses take place in the exhaust gas of the engines not equipped with heat recovery devices. The application of clustering of the ship’s operations based on the concept of typical operational days suggests that the use of five typical days provides a good approximation of the yearly ship’s operations and can hence be used for the design and optimization of the energy systems of the ship.
  •  
4.
  • Li, Mao, et al. (författare)
  • Experimental study of hydrogen addition effects on a swirl-stabilized methane-air flame
  • 2017
  • Ingår i: Energies. - : MDPI AG. - 1996-1073. ; 10:11
  • Tidskriftsartikel (refereegranskat)abstract
    • The effects of H2 addition on a premixed methane-air flame was studied experimentally with a swirl-stabilized gas turbine model combustor. Experiments with 0%, 25%, and 50% H2 molar fraction in the fuel mixture were conducted under atmospheric pressure. The primary objectives are to study the impacts of H2 addition on flame lean blowout (LBO) limits, flame shapes and anchored locations, flow field characteristics, precessing vortex core (PVC) instability, as well as the CO emission performance. The flame LBO limits were identified by gradually reducing the equivalence ratio until the condition where the flame physically disappeared. The time-averaged CH chemiluminescence was used to reveal the characteristics of flame stabilization, e.g., flame structure and stabilized locations. In addition, the inverse Abel transform was applied to the time-averaged CH results so that the distribution of CH signal on the symmetric plane of the flame was obtained. The particle image velocimetry (PIV) was used to detect the characteristics of the flow field with a frequency of 2 kHz. The snapshot method of POD (proper orthogonal decomposition) and fast Fourier transform (FFT) were adopted to capture the most prominent coherent structures in the turbulent flow field. CO emission was monitored with an exhaust probe that was installed close to the combustor exit. The experimental results indicated that the H2 addition extended the flame LBO limits and the operation range of low CO emission. The influence of H2 addition on the flame shape, location, and flow field was observed. With the assistance of POD and FFT, the combustion suppression impacts on PVC was found.
  •  
5.
  • Li, Mao, et al. (författare)
  • Impact of vitiation on a swirl-stabilized and premixed methane flame
  • 2017
  • Ingår i: Energies. - : MDPI AG. - 1996-1073. ; 10:10
  • Tidskriftsartikel (refereegranskat)abstract
    • Vitiation refers to the condition where the oxygen concentration in the air is reduced due to the mix of dilution gas. The vitiation effects on a premixed methane flame were investigated on a swirl-stabilized gas turbine model combustor under atmospheric pressure. The main purpose is to analyze the combustion stability and CO emission performance in vitiated air and compare the results with the flame without vitiation. The N2, CO2, and H2O (steam) were used as the dilution gas. Measurements were conducted in a combustor inlet temperature of 384 K and 484 K. The equivalence ratio was varied from stoichiometric conditions to the LBO (Lean Blowout) limits where the flame was physically blown out from the combustor. The chemical kinetics calculation was performed with Chemkin software to analyze the vitiation effects on the flame reaction zone. Based on the calculation results, the changes in the temperature gradient, CO concentration, and active radicals across the flame reaction zone were identified. The time-Averaged CH chemiluminescence images were recorded and the results indicated the features of the flame shape and location. The CH signal intensity provided the information about the heat-release zone in the combustor. The combustion LBO limits were measured and the vitiation of CO2 and H2O were found to have a stronger impact to elevate the LBO limits than N2. Near the LBO limits, the instability of the flame reaction was revealed by the high-speed chemiluminescence imaging and the results were analyzed by FFT (Fast Fourier Transfer). CO emission was measured with a water-cooled probe which is located at the exit of the combustor. The combustion vitiation has been found to have the compression effect on the operation range for low CO emission. However, this compression effect could be compensated by improving the combustor inlet temperature.
  •  
6.
  • Li, Mao, et al. (författare)
  • Influence of the steam addition on premixed methane air combustion at atmospheric pressure
  • 2017
  • Ingår i: Energies. - : MDPI AG. - 1996-1073. ; 10:7
  • Tidskriftsartikel (refereegranskat)abstract
    • Steam-diluted combustion in gas turbine systems is an effective approach to control pollutant emissions and improve the gas turbine efficiency. The primary purpose of the present research is to analyze the influence of steam dilution on the combustion stability, flame structures, and CO emissions of a swirl-stabilized gas turbine model combustor under atmospheric pressure conditions. The premixed methane/air/steam flame was investigated with three preheating temperatures (384 K/434 K/484 K) and the equivalence ratio was varied from stoichiometric conditions to the flammability limits where the flame was physically blown out from the combustor. In order to represent the steam dilution intensity, the steam fraction Ω defined as the steam to air mass flow rate ratio was used in this work. Exhaust gases were sampled with a water-cooled emission probe which was mounted at the combustor exit. A 120 mm length quartz liner was used which enabled the flame visualization and optical measurement. Time-averaged CH chemiluminescence imaging was conducted to characterize the flame location and it was further analyzed with the inverse Abel transform method. Chemical kinetics calculation was conducted to support and analyze the experimental results. It was found that the LBO (lean blowout) limits were increased with steam fraction. CH chemiluminescence imaging showed that with a high steam fraction, the flame length was elongated, but the flame structure was not altered. CO emissions were mapped as a function of the steam fraction, inlet air temperature, and equivalence ratios. Stable combustion with low CO emission can be achieved with an appropriate steam fraction operation range.
  •  
7.
  • Li, Mao, et al. (författare)
  • Investigation of methane oxy-fuel combustion in a swirl-stabilised gas turbine model combustor
  • 2017
  • Ingår i: Energies. - : MDPI AG. - 1996-1073. ; 10:5
  • Tidskriftsartikel (refereegranskat)abstract
    • CO2 has a strong impact on both operability and emission behaviours in gas turbine combustors. In the present study, an atmospheric, preheated, swirl-stabilised optical gas turbine model combustor rig was employed. The primary objectives were to analyse the influence of CO2 on the fundamental characteristics of combustion, lean blowout (LBO) limits, CO emission and flame structures. CO2 dilution effects were examined with three preheating temperatures (396.15, 431.15, and 466.15 K). The fundamental combustion characteristics were studied utilising chemical kinetic simulations. To study the influence of CO2 on the operational range of the combustor, equivalence ratio (Φ) was varied from stoichiometric conditions to the LBO limits. CO emissions were measured at the exit of the combustor using a water-cooled probe over the entire operational range. The flame structures and locations were characterised by performing CH chemiluminescence imaging. The inverse Abel transformation was used to analyse the CH distribution on the axisymmetric plane of the combustor. Chemical kinetic modelling indicated that the CO2 resulted in a lower reaction rate compared with the CH4/air flame. Fundamental combustion properties such as laminar flame speed, ignition delay time and blowout residence time were found to be affected by CO2. The experimental results revealed that CO2 dilution resulted in a narrower operational range for the equivalence ratio. It was also found that CO2 had a strong inhibiting effect on CO burnout, which led to a higher concentration of CO in the combustion exhaust. CH chemiluminescence showed that the CO2 dilution did not have a significant impact on the flame structure.
  •  
8.
  • Månsson, Sara, et al. (författare)
  • A fault handling process for faults in district heating customer installations
  • 2021
  • Ingår i: Energies. - : MDPI AG. - 1996-1073. ; 14:11
  • Tidskriftsartikel (refereegranskat)abstract
    • Faults in district heating (DH) customer installations cause high return temperatures, which have a negative impact on both current and future district heating systems. Thus, there is a need to detect and correct these faults soon after they occur to minimize their impact on the system. This paper, therefore, suggests a fault handling process for the detection and elimination of faults in DH customer installations. The fault handling process is based on customer data analysis since many faults manifest in customer data. The fault handling process was based on an analysis of the results from the previous fault handling studies, as well as conducting a workshop with experts from the DH industry. During the workshop, different organizational and technical challenges related to fault handling were discussed. The results include a presentation of how the utilities are currently working with fault handling. The results also present an analysis of different organizational aspects that would have to be improved to succeed in fault handling. The paper also includes a suggestion for how a fault handling process based on fault detection using data analysis may be designed. This process may be implemented by utilities in both current and future DH systems that interested in working more actively with faults in their customer installations.
  •  
9.
  • Månsson, Sara, et al. (författare)
  • Automated Statistical Methods for Fault Detection in District Heating Customer Installations
  • 2018
  • Ingår i: Energies. - : MDPI AG. - 1996-1073. ; 12:113
  • Tidskriftsartikel (refereegranskat)abstract
    • In order to develop more sustainable district heating systems, the district heating sector is currently trying to increase the energy efficiency of these systems. One way of doing so is to identify customer installations in the systems that have poor cooling performance. This study aimed to develop an algorithm that was able to detect the poorly performing installations automatically using meter readings from the installations. The algorithm was developed using statistical methods and was tested on a data set consisting of data from 3000 installations located in a district heating system in Sweden. As many as 1273 installations were identified by the algorithm as having poor cooling performance. This clearly shows that it is of major interest to the district heating companies to identify the installations with poor cooling performance rapidly and automatically, in order to rectify them as soon as possible
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy