SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0094 2405 OR L773:2473 4209 srt2:(2020-2021)"

Sökning: L773:0094 2405 OR L773:2473 4209 > (2020-2021)

  • Resultat 1-10 av 25
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Andersén, Christoffer, 1991-, et al. (författare)
  • Deep learning based digitisation of prostate brachytherapy needles in ultrasound images
  • 2020
  • Ingår i: Medical physics. - : Wiley-Blackwell Publishing Inc.. - 2473-4209 .- 0094-2405. ; 47:12, s. 6414-6420
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To develop, and evaluate the performance of, a deep learning based 3D convolutional neural network (CNN) artificial intelligence (AI) algorithm aimed at finding needles in ultrasound images used in prostate brachytherapy.METHODS: Transrectal ultrasound (TRUS) image volumes from 1102 treatments were used to create a clinical ground truth (CGT) including 24422 individual needles that had been manually digitised by medical physicists during brachytherapy procedures. A 3D CNN U-net with 128x128x128 TRUS image volumes as input was trained using 17215 needle examples. Predictions of voxels constituting a needle were combined to yield a 3D linear function describing the localisation of each needle in a TRUS volume. Manual and AI digitisations were compared in terms of the root-mean-square distance (RMSD) along each needle, expressed as median and interquartile range (IQR). The method was evaluated on a dataset including 7207 needle examples. A subgroup of the evaluation data set (n=188) was created, where the needles were digitised once more by a medical physicist (G1) trained in brachytherapy. The digitisation procedure was timed.RESULTS: The RMSD between the AI and CGT was 0.55 (IQR: 0.35-0.86) mm. In the smaller subset, the RMSD between AI and CGT was similar (0.52 [IQR: 0.33-0.79] mm) but significantly smaller (p<0.001) than the difference of 0.75 (IQR: 0.49-1.20) mm between AI and G1. The difference between CGT and G1 was 0.80 (IQR: 0.48-1.18) mm, implying that the AI performed as well as the CGT in relation to G1. The mean time needed for human digitisation was 10 min 11 sec, while the time needed for the AI was negligible.CONCLUSIONS: A 3D CNN can be trained to identify needles in TRUS images. The performance of the network was similar to that of a medical physicist trained in brachytherapy. Incorporating a CNN for needle identification can shorten brachytherapy treatment procedures substantially.
  •  
2.
  • Andersson, Jonas, 1975-, et al. (författare)
  • Estimation of patient skin dose in fluoroscopy : summary of a joint report by AAPM TG357 and EFOMP
  • 2021
  • Ingår i: Medical physics (Lancaster). - : John Wiley & Sons. - 0094-2405 .- 2473-4209. ; 48:7, s. e671-e696
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Physicians use fixed C-arm fluoroscopy equipment with many interventional radiological and cardiological procedures. The associated effective dose to a patient is generally considered low risk, as the benefit-risk ratio is almost certainly highly favorable. However, X-ray-induced skin injuries may occur due to high absorbed patient skin doses from complex fluoroscopically guided interventions (FGI). Suitable action levels for patient-specific follow-up could improve the clinical practice. There is a need for a refined metric regarding follow-up of X-ray-induced patient injuries and the knowledge gap regarding skin dose-related patient information from fluoroscopy devices must be filled. The most useful metric to indicate a risk of erythema, epilation or greater skin injury that also includes actionable information is the peak skin dose, that is, the largest dose to a region of skin.Materials and Methods: The report is based on a comprehensive review of best practices and methods to estimate peak skin dose found in the scientific literature and situates the importance of the Digital Imaging and Communication in Medicine (DICOM) standard detailing pertinent information contained in the Radiation Dose Structured Report (RDSR) and DICOM image headers for FGI devices. Furthermore, the expertise of the task group members and consultants have been used to bridge and discuss different methods and associated available DICOM information for peak skin dose estimation.Results: The report contributes an extensive summary and discussion of the current state of the art in estimating peak skin dose with FGI procedures with regard to methodology and DICOM information. Improvements in skin dose estimation efforts with more refined DICOM information are suggested and discussed.Conclusions: The endeavor of skin dose estimation is greatly aided by the continuing efforts of the scientific medical physics community, the numerous technology enhancements, the dose-controlling features provided by the FGI device manufacturers, and the emergence and greater availability of the DICOM RDSR. Refined and new dosimetry systems continue to evolve and form the infrastructure for further improvements in accuracy. Dose-related content and information systems capable of handling big data are emerging for patient dose monitoring and quality assurance tools for large-scale multihospital enterprises.
  •  
3.
  • Arce, P., et al. (författare)
  • Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group
  • 2021
  • Ingår i: Medical Physics. - : Wiley. - 0094-2405 .- 2473-4209. ; 48:1, s. 19-56
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Geant4 is a Monte Carlo code extensively used in medical physics for a wide range of applications, such as dosimetry, micro- and nanodosimetry, imaging, radiation protection, and nuclear medicine. Geant4 is continuously evolving, so it is crucial to have a system that benchmarks this Monte Carlo code for medical physics against reference data and to perform regression testing. Aims: To respond to these needs, we developed G4-Med, a benchmarking and regression testing system of Geant4 for medical physics. Materials and Methods: G4-Med currently includes 18 tests. They range from the benchmarking of fundamental physics quantities to the testing of Monte Carlo simulation setups typical of medical physics applications. Both electromagnetic and hadronic physics processes and models within the prebuilt Geant4 physics lists are tested. The tests included in G4-Med are executed on the CERN computing infrastructure via the use of the geant-val web application, developed at CERN for Geant4 testing. The physical observables can be compared to reference data for benchmarking and to results of previous Geant4 versions for regression testing purposes. Results: This paper describes the tests included in G4-Med and shows the results derived from the benchmarking of Geant4 10.5 against reference data. Discussion: Our results indicate that the Geant4 electromagnetic physics constructor G4EmStandardPhysics_option4 gives a good agreement with the reference data for all the tests. The QGSP_BIC_HP physics list provided an overall adequate description of the physics involved in hadron therapy, including proton and carbon ion therapy. New tests should be included in the next stage of the project to extend the benchmarking to other physical quantities and application scenarios of interest for medical physics. Conclusion: The results presented and discussed in this paper will aid users in tailoring physics lists to their particular application.
  •  
4.
  • Böck, Michelle (författare)
  • On adaptation cost and tractability in robust adaptive radiation therapy optimization
  • 2020
  • Ingår i: Medical physics (Lancaster). - : Wiley. - 0094-2405 .- 2473-4209. ; 47:7, s. 2791-2804
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose In this paper, a framework for online robust adaptive radiation therapy (ART) is discussed and evaluated. The purpose of the presented approach to ART is to: (a) handle interfractional geometric variations following a probability distribution different from the a priori hypothesis, (b) address adaptation cost, and Methods A novel framework for online robust ART using the concept of Bayesian inference and scenario reduction is introduced and evaluated in a series of simulated cases on a one-dimensional phantom geometry. The initial robust plan is generated from a robust optimization problem based on either expected-value or worst-case optimization approach using the a priori hypothesis of the probability distribution governing the interfractional geometric variations. Throughout the course of treatment, the simulated interfractional variations are evaluated in terms of their likelihood with respect to the a priori hypothesis of their distribution and violation of user-specified tolerance limits by the accumulated dose. If an adaptation is considered, the a posteriori distribution is computed from the actual variations using Bayesian inference. Then, the adapted plan is optimized to better suit the actual interfractional variations of the individual case. This adapted plan is used until the next adaptation is triggered. To address adaptation cost, the proposed framework provides an option for increased adaptation frequency. Computational tractability in robust planning and ART is addressed by an approximation algorithm to reduce the size of the optimization problem. Results According to the simulations, the proposed framework may improve target coverage compared to the corresponding nonadaptive robust approach. In particular, Bayesian inference may be useful to individualize plans to the actual interfractional variations. Concerning adaptation cost, the results indicate that mathematical methods like Bayesian inference may have a greater impact on improving individual treatment quality than increased adaptation frequency. In addition, the simulations suggest that the concept of scenario reduction may be useful to address computational tractability in ART and robust planning in general. Conclusions The simulations indicate that the adapted plans may improve target coverage and OAR protection at manageable adaptation and computational cost within the novel framework. In particular, adaptive strategies using Bayesian inference appear to perform best among all strategies. This proof-of-concept study provides insights into the mathematical aspects of robustness, tractability, and ART, which are a useful guide for further development of frameworks for online robust ART.
  •  
5.
  • Das, Indra J., et al. (författare)
  • Report of AAPM Task Group 155 : Megavoltage photon beam dosimetry in small fields and non-equilibrium conditions
  • 2021
  • Ingår i: Medical physics (Lancaster). - : John Wiley & Sons. - 0094-2405 .- 2473-4209. ; 48:10, s. E886-E921
  • Tidskriftsartikel (refereegranskat)abstract
    • Small-field dosimetry used in advance treatment technologies poses challenges due to loss of lateral charged particle equilibrium (LCPE), occlusion of the primary photon source, and the limited choice of suitable radiation detectors. These challenges greatly influence dosimetric accuracy. Many high-profile radiation incidents have demonstrated a poor understanding of appropriate methodology for small-field dosimetry. These incidents are a cause for concern because the use of small fields in various specialized radiation treatment techniques continues to grow rapidly. Reference and relative dosimetry in small and composite fields are the subject of the International Atomic Energy Agency (IAEA) dosimetry code of practice that has been published as TRS-483 and an AAPM summary publication (IAEA TRS 483; Dosimetry of small static fields used in external beam radiotherapy: An IAEA/AAPM International Code of Practice for reference and relative dose determination, Technical Report Series No. 483; Pal-mans et al., Med Phys 45(11):e1123, 2018). The charge of AAPM task group 155 (TG-155) is to summarize current knowledge on small-field dosimetry and to provide recommendations of best practices for relative dose determination in small megavoltage photon beams. An overview of the issue of LCPE and the changes in photon beam perturbations with decreasing field size is provided. Recommendations are included on appropriate detector systems and measurement methodologies. Existing published data on dosimetric parameters in small photon fields (e.g., percentage depth dose, tissue phantom ratio/tissue maximum ratio, off-axis ratios, and field output factors) together with the necessary perturbation corrections for various detectors are reviewed. A discussion on errors and an uncertainty analysis in measurements is provided. The design of beam models in treatment planning systems to simulate small fields necessitates special attention on the influence of the primary beam source and collimating devices in the computation of energy fluence and dose. The general requirements for fluence and dose calculation engines suitable for modeling dose in small fields are reviewed. Implementations in commercial treatment planning systems vary widely, and the aims of this report are to provide insight for the medical physicist and guidance to developers of beams models for radiotherapy treatment planning systems.
  •  
6.
  •  
7.
  • Holmes, Robin B., et al. (författare)
  • Creation of an anthropomorphic CT head phantom for verification of image segmentation
  • 2020
  • Ingår i: Medical physics (Lancaster). - : Wiley-Blackwell. - 0094-2405 .- 2473-4209. ; 47:6, s. 2380-2391
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Many methods are available to segment structural magnetic resonance (MR) images of the brain into different tissue types. These have generally been developed for research purposes but there is some clinical use in the diagnosis of neurodegenerative diseases such as dementia. The potential exists for computed tomography (CT) segmentation to be used in place of MRI segmentation, but this will require a method to verify the accuracy of CT processing, particularly if algorithms developed for MR are used, as MR has notably greater tissue contrast.Methods: To investigate these issues we have created a three-dimensional (3D) printed brain with realistic Hounsfield unit (HU) values based on tissue maps segmented directly from an individual T1 MRI scan of a normal subject. Several T1 MRI scans of normal subjects from the ADNI database were segmented using SPM12 and used to create stereolithography files of different tissues for 3D printing. The attenuation properties of several material blends were investigated, and three suitable formulations were used to print an object expected to have realistic geometry and attenuation properties. A skull was simulated by coating the object with plaster of Paris impregnated bandages. Using two CT scanners, the realism of the phantom was assessed by the measurement of HU values, SPM12 segmentation and comparison with the source data used to create the phantom.Results: Realistic relative HU values were measured although a subtraction of 60 was required to obtain equivalence with the expected values (gray matter 32.9-35.8 phantom, 29.9-34.2 literature). Segmentation of images acquired at different kVps/mAs showed excellent agreement with the source data (Dice Similarity Coefficient 0.79 for gray matter). The performance of two scanners with two segmentation methods was compared, with the scanners found to have similar performance and with one segmentation method clearly superior to the other.Conclusion: The ability to use 3D printing to create a realistic (in terms of geometry and attenuation properties) head phantom has been demonstrated and used in an initial assessment of CT segmentation accuracy using freely available software developed for MRI.
  •  
8.
  • Häger, Wille, et al. (författare)
  • Experimental investigation of TRS-483 reference dosimetry correction factors for Leksell Gamma Knife (R) Icon (TM) beams
  • 2021
  • Ingår i: Medical physics (Lancaster). - : Wiley. - 0094-2405 .- 2473-4209. ; 48:1, s. 434-444
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Radiosurgery using the Leksell Gamma Knife (R) (LGK) Icon (TM) is an established technique used for treating intracranial lesions. The largest beam field size the LGK Icon can produce is a 16 mm diameter sphere. Despite this, reference dosimetry on the LGK Icon is typically performed using ionization chambers calibrated in 10 x 10 cm(2) fields. Furthermore, plastic phantoms are widely used instead of liquid water phantoms. In an effort to resolve these issues, the International Atomic Energy Agency (IAEA) in collaboration with American Association of Physicists in medicine (AAPM) recently published Technical Report Series No. 483 (TRS-483) as a Code of Practice for small-field dosimetry. TRS-483 includes small-field correction factors, k(Qmsr,Q0)(fmsr,fref), intended to account for the differences between setups when using small-field modalities such as the LGK Icon, and conventional setups. Since the publication of TRS-483, at least three new sets of values of k(Qmsr,Q0)(fmsr,fref) for the LGK Icon have been published. The purpose of this study was to experimentally investigate the published values of k(Qmsr,Q0)(fmsr,fref) for commonly used phantom and ionization chamber (IC) models for the LGK Icon.Methods: Dose-rates from two LGK units were determined using acrylonitrile butadiene styrene (ABS) and Certified Medical Grade Solid Water (R) (SW) phantoms, and PTW 31010 and PTW 31016 ICs. Correction factors were applied, and the resulting dose-rates compared. Relative validity of the correction factors was investigated by taking the ratios of dose-rate correction factor products. Additionally, dose-rates from the individual sectors were determined in order to calculate the beam attenuation caused by the ABS phantom adapter.Results and Conclusions: It was seen that the dose-rate is underestimated by at least 1% when using the ABS phantom, which was attributed to fluence perturbation caused by the IC and phantom adapter. Published correction factors k(Qmsr,Q0)(fmsr,fref) account for these effects to varying degree and should be used. The SW phantom is unlikely to underestimate the dose-rate by more than 1%, and applying k(Qmsr,Q0)(fmsr,fref) could not be shown to be necessary. Out of the two phantom models, the ABS phantom is not recommended for use in LGK reference dosimetry. The use of newly published values of k(Qmsr,Q0)(fmsr,fref) should be considered.
  •  
9.
  • Johansson, Adam, et al. (författare)
  • Gastrointestinal 4D MRI with respiratory motion correction
  • 2021
  • Ingår i: Medical physics (Lancaster). - : John Wiley & Sons. - 0094-2405 .- 2473-4209. ; 48:5, s. 2521-2527
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose Gastrointestinal motion patterns such as peristalsis and segmental contractions can alter the shape and position of the stomach and intestines with respect to other irradiated organs during radiation therapy. Unfortunately, these deformations are concealed by conventional four-dimensional (4D)-MRI techniques, which were developed to visualize respiratory motion by binning acquired data into respiratory motion states without considering the phases of GI motion. We present a method to reconstruct breathing-compensated images showing the phases of periodic gastric motion and study the effect of this motion on regional anatomical structures. Methods Sixty-seven DCE-MRI examinations were performed on patients undergoing MRI simulation for hepatocellular carcinoma using a golden-angle stack-of-stars sequence that collected 2000 radial spokes over 5 min. The collected data were reconstructed using a method with integrated respiratory motion correction into a time series of 3D image volumes without visible breathing motion. From this series, a gastric motion signal was extracted by temporal filtering of time-intensity curves in the stomach. Using this motion signal, breathing-corrected back-projection images were sorted according to the gastric phase and reconstructed into 21 gastric motion state images showing the phases of gastric motion. Results Reconstructed image volumes showed gastric motion states clearly with no visible breathing motion or related artifacts. The mean frequency of the gastric motion signal was 3 cycles/min with a standard deviation of 0.27 cycles/min. Conclusions Periodic gastrointestinal motion can be visualized without confounding respiratory motion using the presented GI 4D MRI technique. GI 4D MRIs may help define internal target volumes for treatment planning, aid in planning organ at risk volume definition, or support motion model development for gastrointestinal motion tracking algorithms for real-time MR-guided radiation therapy.
  •  
10.
  • Kaveckyte, Vaiva, et al. (författare)
  • Investigation of a synthetic diamond detector response in kilovoltage photon beams
  • 2020
  • Ingår i: Medical physics (Lancaster). - : Wiley-Blackwell Publishing Inc.. - 0094-2405 .- 2473-4209. ; 47:3, s. 1268-1279
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose An important characteristic of radiation dosimetry detectors is their energy response which consists of absorbed-dose and intrinsic energy responses. The former can be characterized using Monte Carlo (MC) simulations, whereas the latter (i.e., detector signal per absorbed dose to detector) is extracted from experimental data. Such a characterization is especially relevant when detectors are used in nonrelative measurements at a beam quality that differs from the calibration beam quality. Having in mind the possible application of synthetic diamond detectors (microDiamond PTW 60019, Freiburg, Germany) for nonrelative dosimetry of low-energy brachytherapy (BT) beams, we determined their intrinsic and absorbed-dose energy responses in 25-250 kV beams relative to a Co-60 beam, which is usually the reference beam quality for detector calibration in radiotherapy. Material and Methods Three microDiamond detectors and, for comparison, two silicon diodes (PTW 60017) were calibrated in terms of air-kerma free in air in six x-ray beam qualities (from 25 to 250 kV) and in terms of absorbed dose to water in a Co-60 beam at the national metrology laboratory in Sweden. The PENELOPE/penEasy MC radiation transport code was used to calculate the absorbed-dose energy response of the detectors (modeled based on blueprints) relative to air and water depending on calibration conditions. The MC results were used to extract the relative intrinsic energy response of the detectors from the overall energy response. Measurements using an independent setup with a single ophthalmic BEBIG I25.S16 I-125 BT seed (effective photon energy of 28 keV) were used as a qualitative check of the extracted intrinsic energy response correction factors. Additionally, the impact of the thickness of the active volume as well as the presence of extra-cameral components on the absorbed-dose energy response of a microDiamond detector was studied using MC simulations. Results The relative intrinsic energy response of the microDiamond detectors was higher by a factor of 2 in 25 and 50 kV beams compared to the Co-60 beam. The variation in the relative intrinsic energy response of silicon diodes was within 10% over the investigated photon energy range. The use of relative intrinsic energy response correction factors improved the agreement among the absorbed dose to water values determined using microDiamond detectors and silicon diodes, as well as with the TG-43 formalism-based calculations for the I-125 seed. MC study of microDiamond detector design features provided a possible explanation for inter-detector response variation at low-energy photon beams by differences in the effective thickness of the active volume. Conclusions MicroDiamond detectors had a non-negligible variation in the relative intrinsic energy response (factor of 2) which was comparable to that in the absorbed-dose energy response relative to water at low-energy photon beams. Silicon diodes, in contrast, had an absorbed-dose energy dependence on photon energy that varied by a factor of 6, whereas the intrinsic energy dependence on beam quality was within 10%. It is important to decouple these two responses for a full characterization of detector energy response especially when the user and reference beam qualities differ significantly, and MC alone is not enough.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 25
Typ av publikation
tidskriftsartikel (24)
forskningsöversikt (1)
Typ av innehåll
refereegranskat (24)
övrigt vetenskapligt/konstnärligt (1)
Författare/redaktör
Andreo, P (4)
Ahnesjö, Anders, 195 ... (2)
Andersson, Jonas, 19 ... (2)
Dondero, P. (1)
Dotti, A. (1)
Omachi, C. (1)
visa fler...
Sasaki, T. (1)
Sakata, D. (1)
Knöös, Tommy (1)
Quesada, J M (1)
Ceberg, Sofie (1)
Perrot, Y (1)
Pandola, L. (1)
Cuttone, G (1)
Romano, F (1)
Rydén, Tobias (1)
Nyholm, Tufve (1)
Alm Carlsson, Gudrun (1)
Carlsson Tedgren, Ås ... (1)
Carlsson Tedgren, Ås ... (1)
Delgado, AF (1)
Nilsson, Kristina (1)
Soderman, M (1)
Incerti, S (1)
Traneus, Erik (1)
Isacsson, Ulf (1)
Toma-Daşu, Iuliana (1)
Kügele, Malin (1)
Cortes-Giraldo, M. A ... (1)
Olsson, Jimmy (1)
Guatelli, S (1)
Ivanchenko, V (1)
Maire, M (1)
Mantero, A (1)
Bujila, R (1)
Novak, M (1)
Andersén, Christoffe ... (1)
Thunberg, Per, 1968- (1)
H. Lagerlöf, Jakob, ... (1)
Granberg, Christoffe ... (1)
Pavlicek, William (1)
Bolch, Wesley (1)
Bosmans, Hilde (1)
Kanal, Kalpana (1)
McDonagh, Ed (1)
Paden, Robert (1)
Torresin, Alberto (1)
Trianni, Annalisa (1)
Zamora, David (1)
Bednarek, Daniel R. (1)
visa färre...
Lärosäte
Karolinska Institutet (9)
Umeå universitet (4)
Uppsala universitet (4)
Kungliga Tekniska Högskolan (3)
Stockholms universitet (3)
Linköpings universitet (3)
visa fler...
Lunds universitet (3)
Örebro universitet (1)
Chalmers tekniska högskola (1)
visa färre...
Språk
Engelska (25)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (13)
Naturvetenskap (7)
Teknik (6)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy