Diagnosis of early glaucoma with flicker comparisons of serial disc photographs

Heijl, A (författare)
Lund University,Lunds universitet,Oftalmologi (Malmö),Forskargrupper vid Lunds universitet,Ophthalmology (Malmö),Lund University Research Groups
Bengtsson, B (författare)
Lund University,Lunds universitet,Oftalmologi (Malmö),Forskargrupper vid Lunds universitet,Ophthalmology (Malmö),Lund University Research Groups
 (creator_code:org_t)
1989
1989
Engelska 9 s.
Ingår i: Investigative Ophthalmology & Visual Science. - 0146-0404. ; 30:11, s. 84-2376
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We evaluated flicker comparison, a technique for detecting differences in serial fundus photographs. Serial optic disc photographs and computerized threshold visual fields were obtained every 3 months for an average of 40 months in 131 eyes of 81 patients with elevated intraocular pressure and normal visual fields. Two serial monophotographs were projected, optically aligned, and superimposed; analysis was done by alternately viewing first one and then the other image. We found flicker analysis of serial disc photographs to provide results which were closely correlated with those of computerized threshold perimetry. Thus, of those 12 eyes which developed field defects, eight showed definite change and two showed highly suspected change in optic disc configuration. Only two eyes showed a definite alteration in optic disc anatomy without the development of field loss, and field defects appeared in only one of 109 eyes in which there was no change or suspected change on flicker comparison. The flicker method was more sensitive than conventional nonflickered comparisons, but changes could usually be seen also with conventional inspection once they had been detected by the flicker method. Our findings suggest that flicker analysis may offer a considerable improvement over current standard methods of analyzing serial photography and may be a useful complement to routine perimetry. However, this method requires special equipment; requires that the photographs be similarly centered; and is time-consuming. Alignment of photographs by means of computerized image analysis techniques could make the method clinically practicable.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Nyckelord

Diagnosis, Differential
Flicker Fusion
Glaucoma
Humans
Intraocular Pressure
Ocular Hypertension
Optic Disk
Photography
Visual Field Tests
Visual Fields

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Heijl, A
Bengtsson, B
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Oftalmologi
Artiklar i publikationen
Investigative Op ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy