  • Dhainaut, Alvilde, et al. (författare)
  • Long-term in-vitro precision of direct digital X-ray radiogrammetry
  • 2011
  • Ingår i: Skeletal Radiology. - : Springer Science and Business Media LLC. - 1432-2161 .- 0364-2348. ; 40:12, s. 1575-1579
  • Tidskriftsartikel (refereegranskat)abstract
    • Digital X-ray radiogrammetry (DXR) calculates peripheral bone mineral density (BMD) from hand radiographs. The short-term precision for direct DXR has been reported to be highly satisfactory. However, long-term precision for this method has not been examined. Thus, the aim of this study was to examine the long-term in-vitro precision for the new direct digital version of DXR. The in-vitro precision for direct DXR was tested with cadaver phantoms on four different X-ray systems at baseline, 3 months, 6 months, and in one machine also at 12 months. At each time point, 31 measurements were performed. The in-vitro longitudinal precision for the four radiographic systems ranged from 0.22 to 0.43% expressed as coefficient of variation (CV%). The smallest detectable difference (SDD) ranged from 0.0034 to 0.0054 g/cm(2). The in vitro long-term precision for direct DXR was comparable to the previous reported short-term in-vitro precision for all tested X-ray systems. These data show that DXR is a stable method for detecting small changes in bone density during 6-12 months of follow-up.
  •  
2.
  • Geijer, Mats, 1957, et al. (författare)
  • Clinical utility of tomosynthesis in suspected scaphoid fracture. A pilot study.
  • 2011
  • Ingår i: Skeletal radiology. - : Springer Science and Business Media LLC. - 1432-2161 .- 0364-2348. ; 40:7, s. 863-7
  • Tidskriftsartikel (refereegranskat)abstract
    • Radiography alone will not detect all scaphoid fractures. There is a reported prevalence between 9 and 33% of occult scaphoid fractures. The evidence-based literature suggests that magnetic resonance imaging (MRI) is the most suitable secondary imaging modality due to the ability to evaluate the bone marrow directly and to also identify other injuries. However, there is no consensus on the choice of follow-up imaging strategy-computed tomography, MRI, or bone scan-across different institutions. Tomosynthesis is a new digital tomographic method creating multiple thin tomographic sections. The purpose of this study was to evaluate the clinical utility of tomosynthesis in suspected occult fracture.
  •  
3.
  • Gärdin, Anna, et al. (författare)
  • The long-term clinical and MRI results following eccentric calf muscle training in chronic Achilles tendinosis
  • 2010
  • Ingår i: Skeletal Radiology. - : Springer Science and Business Media LLC. - 0364-2348 .- 1432-2161. ; 39:5, s. 435-442
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To evaluate the long-term results following eccentric calf-muscle training in patients with chronic Achilles tendinopathy.MATERIALS AND METHODS: A total of 24 patients with chronic Achilles tendinopathy were included in a study evaluating MRI findings and clinical symptoms before and after 3 months of daily eccentric calf-muscle strength training. Median duration of symptoms was 18 months (range 6-120). Four of the patients did not perform the prescribed treatment for different reasons and were followed for 14 months. The resulting 20 treated patients completed 4.2-year (range 29-58 months) follow up. Tendon volume was evaluated by using 3D seed growing technique and signal abnormalities were visually semi-quantitatively graded. Level of pain and performance was categorized using a questionnaire completed by the patient.RESULTS: In the symptomatic treated patients, median intensity level of pain decreased from moderate/severe at time of inclusion to mild at follow up (p < 0.05). Median level of performance increased from severe impairment at time of inclusion to normal at follow up (p < 0.05). 12 out of 20 patients had raised intratendinous signal at time of inclusion compared to 2 out of 20 patients at follow up (p < 0.001). Mean tendon-volume measured 6.7 cm(3) (SD 2.0) at time of inclusion and 6.4 cm(3) (SD 2.0) at follow up (p = 0.18). The four symptomatic non-treated tendons did not improve regarding pain, performance, intratendinous signal or tendon volume.CONCLUSION: We found decreased pain, improved performance and decreased intratendinous signal both compared to index examination and immediately after the 3 months training regimen in a 4.2-year clinical and MRI follow up, in a group of patients treated with heavy loaded eccentric calf-muscle training for chronic Achilles tendinopathy. The improvements were greater at 4.2-year follow up, despite no further active treatment, than immediately after the treatment. This may indicate a good long-term prognosis for Achilles tendinosis patients.
  •  
4.
  • Kjellberg, Martin, et al. (författare)
  • Measurement of leg length discrepancy after total hip arthroplasty : the reliability of a plain radiographic method compared to CT-scanogram
  • 2012
  • Ingår i: Skeletal Radiology. - : Springer London. - 0364-2348 .- 1432-2161. ; 41:2, s. 187-191
  • Tidskriftsartikel (refereegranskat)abstract
    • To measure the interobserver reliability and intraobserver reproducibility of post total hip arthroplasty (THA) leg length discrepancy (LLD) measurement on radiographs as well as to evaluate its accuracy by comparing it with LLD measurement on computed tomographic scanogram (CT-scanogram). In this prospective study, postoperative LLD measurements in ten THA patients were made by four observers on anteroposterior radiographs of the pelvis (inter-teardrop line to the tip of lesser trochanter) and compared to LLD measurements made on CT-scanogram scout views of the lower limb. Two observers repeated the LLD measurements on radiographs 8 weeks after the first measurements. The interobserver reliability of the LLD measurement on plain radiographs was evaluated by comparing the measurements of the four observers and the intraobserver reproducibility by comparing the two repeated measurements made by the two observers. We found excellent interobserver reliability (mean ICC 0.83) and intraobserver reproducibility (ICC 0.90 and 0.88) of the LLD measurements on plain radiographs. There was a moderate to excellent agreement, but with wide variation of measurements among the four observers, when plain radiographic measurement was compared with CT-scanogram (ICC 0.58, 0.60, 0.71, and 0.82). Despite the excellent interobserver reliability and intraobserver reproducibility of LLD measurement on radiographs, clinicians should be aware of its limited accuracy when compared to CT-scanogram.
  •  
5.
  • Klintström, Eva, et al. (författare)
  • Trabecular bone structure parameters from 3D image processing of clinical multi-slice and cone-beam computed tomography data
  • 2014
  • Ingår i: Skeletal Radiology. - : Springer. - 0364-2348 .- 1432-2161. ; 43:2, s. 197-204
  • Tidskriftsartikel (refereegranskat)abstract
    • ObjectiveBone strength depends on both mineral content and bone structure. The aim of this in vitro study was to develop a method of quantitatively assessing trabecular bone structure by applying three-dimensional image processing to data acquired with multi-slice and cone-beam computed tomography using micro-computed tomography as a reference.Materials and MethodsFifteen bone samples from the radius were examined. After segmentation, quantitative measures of bone volume, trabecular thickness, trabecular separation, trabecular number, trabecular nodes, and trabecular termini were obtained.ResultsThe clinical machines overestimated bone volume and trabecular thickness and underestimated trabecular nodes and number, but cone-beam CT to a lesser extent. Parameters obtained from cone beam CT were strongly correlated with μCT, with correlation coefficients between 0.93 and 0.98 for all parameters except trabecular termini.ConclusionsThe high correlation between cone-beam CT and micro-CT suggest the possibility of quantifying and monitoring changes of trabecular bone microarchitecture in vivo using cone beam CT.
  •  