SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "LAR1:cth ;lar1:(hb);lar1:(kth)"

Sökning: LAR1:cth > Högskolan i Borås > Kungliga Tekniska Högskolan

  • Resultat 1-10 av 29
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abtahi, Farhad, 1981-, et al. (författare)
  • Development and preliminary evaluation of an Android based heart rate variability biofeedback system
  • 2014
  • Ingår i: Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE. - : IEEE. - 9781424479290 ; 2014, s. 3382-5
  • Konferensbidrag (refereegranskat)abstract
    • The reduced Heart Rate Variability (HRV) is believed to be associated with several diseases such as congestive heart failure, diabetes and chronic kidney diseases (CKD). In these cases, HRV biofeedback may be a potential intervention method to increase HRV which in turn is beneficial to these patients. In this work, a real-time Android biofeedback application based on a Bluetooth enabled ECG and thoracic electrical bioimpedance (respiration) measurement device has been developed. The system performance and usability have been evaluated in a brief study with eight healthy volunteers. The result demonstrates real-time performance of system and positive effects of biofeedback training session by increased HRV and reduced heart rate. Further development of the application and training protocol is ongoing to investigate duration of training session to find an optimum length and interval of biofeedback sessions to use in potential interventions.
  •  
2.
  • Ayllon, David, et al. (författare)
  • Cole equation and parameter estimation from electrical bioimpedance spectroscopy measurements : A comparative study
  • 2009
  • Ingår i: EMBC. - Buenos Aires : IEEE Engineering in Medicine and Biology. ; , s. 3779-3782, s. 3779-3782
  • Konferensbidrag (refereegranskat)abstract
    • Since there are several applications of Electrical Bioimpedance (EBI) that use the Cole parameters as base of the analysis, to fit EBI measured data onto the Cole equation is a very common practice within Multifrequency-EBI and spectroscopy. The aim of this paper is to compare different fitting methods for EBI data in order to evaluate their suitability to fit the Cole equation and estimate the Cole parameters. Three of the studied fittings are based on the use of Non-Linear Least Squares on the Cole model, one using the real part only, a second using the imaginary part and the third using the complex impedance. Furthermore, a novel fitting method done on the impedance plane, without using any frequency information has been implemented and included in the comparison. Results show that the four methods perform relatively well but the best fitting in terms of standard error of estimate is the fitting obtained from the resistance only. The results support the possibility of measuring only the resistive part of the bioimpedance to accurately fit Cole equation and estimate the Cole parameters, with entailed advantages.
  •  
3.
  • Brown, Shannon, et al. (författare)
  • Intarsia-sensorized band and textrodes for real-time myoelectric pattern recognition
  • 2016
  • Ingår i: Engineering in Medicine and Biology Society (EMBC), 2016 IEEE 38th Annual International Conference of the. - : Institute of Electrical and Electronics Engineers (IEEE). - 1557-170X. - 9781457702204 ; , s. 6074-6077
  • Konferensbidrag (refereegranskat)abstract
    • Surface Electromyography (sEMG) has applications in prosthetics, diagnostics and neuromuscular rehabilitation. Self-adhesive Ag/AgCl are the electrodes preferentially used to capture sEMG in short-term studies, however their long-term application is limited. In this study we designed and evaluated a fully integrated smart textile band with electrical connecting tracks knitted with intarsia techniques and knitted textile electrodes. Real-time myoelectric pattern recognition for motor volition and signal-to-noise ratio (SNR) were used to compare its sensing performance versus the conventional Ag-AgCl electrodes. After a comprehending measurement and performance comparison of the sEMG recordings, no significant differences were found between the textile and the Ag-AgCl electrodes in SNR and prediction accuracy obtained from pattern recognition classifiers.
  •  
4.
  • Buendia, Ruben, 1982, et al. (författare)
  • Estimation of body fluids with bioimpedance spectroscopy: state of the art methods and proposal of novel methods
  • 2015
  • Ingår i: Physiological Measurement. - : IOP Publishing. - 0967-3334 .- 1361-6579. ; 36:10
  • Tidskriftsartikel (refereegranskat)abstract
    • Determination of body fluids is a useful common practice in determination of disease mechanisms and treatments. Bioimpedance spectroscopy (BIS) methods are non-invasive, inexpensive and rapid alternatives to reference methods such as tracer dilution. However, they are indirect and their robustness and validity are unclear. In this article, state of the art methods are reviewed, their drawbacks identified and new methods are proposed. All methods were tested on a clinical database of patients receiving growth hormone replacement therapy. Results indicated that most BIS methods are similarly accurate (e.g. < 0.5 +/- 3.0% mean percentage difference for total body water) for estimation of body fluids. A new model for calculation is proposed that performs equally well for all fluid compartments (total body water, extra-and intracellular water). It is suggested that the main source of error in extracellular water estimation is due to anisotropy, in total body water estimation to the uncertainty associated with intracellular resistivity and in determination of intracellular water a combination of both.
  •  
5.
  • Buendia, Ruben, 1982, et al. (författare)
  • Experimental Validation of a Method for Removing the Capacitive Leakage Artifact from Electrical Bioimpedance Spectroscopy Measurements
  • 2010
  • Ingår i: Measurement Science and Technology. - : IOP Publishing. - 0957-0233 .- 1361-6501. ; 21:11, s. 115802-
  • Tidskriftsartikel (refereegranskat)abstract
    • Often when performing electrical bioimpedance (EBI) spectroscopy measurements, the obtained EBI data present a hook-like deviation, which is most noticeable at high frequencies in the impedance plane. The deviation is due to a capacitive leakage effect caused by the presence of stray capacitances. In addition to the data deviation being remarkably noticeable at high frequencies in the phase and the reactance spectra, the measured EBI is also altered in the resistance and the modulus. If this EBI data deviation is not properly removed, it interferes with subsequent data analysis processes, especially with Cole model-based analyses. In other words, to perform any accurate analysis of the EBI spectroscopy data, the hook deviation mustbe properly removed. Td compensation is a method used to compensate the hook deviation present in EBI data; it consists of multiplying the obtained spectrum, Zmeas(ω), by a complex exponential in the form of exp(–jωTd). Although the method is well known and accepted, Td compensation cannot entirely correct the hook-like deviation; moreover, it lacks solid scientific grounds. In this work, the Td compensation method is revisited, and it is shown that it should not be used to correct the effect of a capacitive leakage; furthermore, a more developed approach for correcting the hook deviation caused by the capacitive leakage is proposed. The method includes a novel correcting expression and a process for selecting the proper values of expressions that are complex and frequency dependent. The correctness of the novel method is validated with the experimental data obtained from measurements from three different EBI applications. The obtained results confirm the sufficiency and feasibility of the correcting method.
  •  
6.
  • Buendia, Rubén, et al. (författare)
  • Robustness study of the different immittance spectra and frequency ranges in bioimpedance spectroscopy analysis for assessment of total body composition.
  • 2014
  • Ingår i: Physiological measurement. - : IOP Publishing. - 1361-6579 .- 0967-3334. ; 35:7, s. 1373-95
  • Tidskriftsartikel (refereegranskat)abstract
    • The estimation of body fluids is a useful and common practice for assessment of disease status and therapy outcomes. Electrical bioimpedance spectroscopy (EBIS) methods are noninvasive, inexpensive and efficient alternatives for determination of body fluids. One of the main source of errors in EBIS measurements in the estimation of body fluids is capacitive coupling. In this paper an analysis of capacitive coupling in EBIS measurements was performed and the robustness of the different immittance spectra against it tested. On simulations the conductance (G) spectrum presented the smallest overall error, among all immittance spectra, in the estimation of the impedance parameters used to estimate body fluids. Afterwards the frequency range of 10-500 kHz showed to be the most robust band of the G spectrum. The accuracy of body fluid estimations from the resulting parameters that utilized G spectrum and parameters provided by the measuring device were tested on EBIS clinical measurements from growth hormone replacement therapy patients against estimations performed with dilution methods. Regarding extracellular fluid, the correlation between each EBIS method and dilution was 0.93 with limits of agreement of 1.06 ± 2.95 l for the device, 1.10 ± 2.94 l for G [10-500 kHz] and 1.04 ± 2.94 l for G [5-1000 kHz]. Regarding intracellular fluid, the correlation between dilution and the device was 0.91, same as for G [10-500 kHz] and 0.92 for G [5-1000 kHz]. Limits of agreement were 0.12 ± 4.46 l for the device, 0.09 ± 4.45 for G [10-500 kHz] and 0.04 ± 4.58 for G [5-1000 kHz]. Such close results between the EBIS methods validate the proposed approach of using G spectrum for initial Cole characterization and posterior clinical estimation of body fluids status.
  •  
7.
  • Darabi, Sozan, 1994, et al. (författare)
  • Green Conducting Cellulose Yarns for Machine-Sewn Electronic Textiles
  • 2020
  • Ingår i: ACS Applied Materials & Interfaces. - : American Chemical Society (ACS). - 1944-8252 .- 1944-8244. ; 12:50, s. 56403-56412
  • Tidskriftsartikel (refereegranskat)abstract
    • The emergence of "green"electronics is a response to the pressing global situation where conventional electronics contribute to resource depletion and a global build-up of waste. For wearable applications, green electronic textile (e-textile) materials present an opportunity to unobtrusively incorporate sensing, energy harvesting, and other functionality into the clothes we wear. Here, we demonstrate electrically conducting wood-based yarns produced by a roll-to-roll coating process with an ink based on the biocompatible polymer:polyelectrolyte complex poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS). The developed e-textile yarns display a, for cellulose yarns, record-high bulk conductivity of 36 Scm-1, which could be further increased to 181 Scm-1 by adding silver nanowires. The PEDOT:PSS-coated yarn could be machine washed at least five times without loss in conductivity. We demonstrate the electrochemical functionality of the yarn through incorporation into organic electrochemical transistors (OECTs). Moreover, by using a household sewing machine, we have manufactured an out-of-plane thermoelectric textile device, which can produce 0.2 μW at a temperature gradient of 37 K.
  •  
8.
  • Ferreira, Javier, 1982-, et al. (författare)
  • AD5933-based Spectrometer for Electrical Bioimpedance Applications
  • 2010
  • Ingår i: Journal of Physics: Conference Series. - : IOP Publishing. - 1742-6596. ; 224:1, s. 012011-
  • Konferensbidrag (refereegranskat)abstract
    • o build an Electrical Bioimpedance (EBI) spectrometer using the Impedance Measurement System-On-Chip AD5933 together with a 4-Electrode Analog Front End (4E-AFE) has been proven practicable. Such small measurement devices can make possible several new applications of EBI technology, especially when combined with functional textiles, which can enable wearable applications for personal health and home monitoring. After the implementation and functional validation of the 4E-AFE-enabled spectrometer, the next natural step is to validate for which EBI applications the 4E-AFE-enabled system is suitable. To test the applicability of this novel spectrometer on several EBI applications, 2R1C equivalent models have been experimentally obtained and impedance spectroscopy measurements have been performed with the system under study and with the SFB7 EBI spectrometer manufactured by ImpediMed. The 2R1C circuit parameters have been estimated with the BioImp software from the spectra obtained with both EBI spectrometers and the estimated values have been compared with the original values used in each circuit model implementation. The obtained results indicated that the 4E-AFE-enabled system cannot beat the performance of the SFB7 in accuracy but it performs better in preciseness. In any case the overall performance indicates that the 4E-AFE-enabled system can perform spectroscopy measurements in the frequency range from 5 to 100 kHz.
  •  
9.
  • Flisberg, Anders, 1958, et al. (författare)
  • Does indomethacin for closure of patent ductus arteriosus affect cerebral function?
  • 2010
  • Ingår i: Acta Paediatrica. - : Wiley. - 0803-5253 .- 1651-2227. ; 99:10, s. 1493-1497
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To study whether indomethacin used in conventional dose for closure of patent ductus arteriosus affects cerebral function measured by Electroencephalograms (EEG) evaluated by quantitative measures. Study design: Seven premature neonates with haemodynamically significant persistent ductus arteriosus were recruited. EEG were recorded before, during and after an intravenous infusion of 0.2 mg/kg indomethacin over 10 min. The EEG was analysed by two methods with different degrees of complexity for the amount of low-activity periods (LAP, "suppressions") as an indicator of affection of cerebral function. Results: Neither of the two methods identified any change in the amount of LAPs in the EEG as compared to before the indomethacin infusion. Conclusion: Indomethacin in conventional dose for closure of patent ductus arteriosus does not affect cerebral function as evaluated by quantitative EEG.
  •  
10.
  • Flisberg, A., et al. (författare)
  • Prognostic capacity of automated quantification of suppression time in the EEG of post-asphyctic full-term neonates
  • 2011
  • Ingår i: Acta Paediatrica. - : Wiley-Blackwell. - 0803-5253 .- 1651-2227. ; 100:10, s. 1338-1343
  • Tidskriftsartikel (refereegranskat)abstract
    • Aim: To evaluate the prognostic capacity of a new method for automatic quantification of the length of suppression time in the electroencephalogram (EEG) of a group of asphyxiated newborn infants. Methods: Twenty-one full-term newborn infants who had been resuscitated for severe birth asphyxia were studied. Eight channel continuous EEG was recorded for prolonged time periods during the first days of life. Artefact detection or rejection was not applied to the signals. The signals were fed through a pretrained classifier and then segmented into burst and suppression periods. Total suppression length per hour was calculated. All surviving patients were followed with structured neurodevelopmental assessments to at least 18 months of age. Results: The patients who developed neurodevelopmental disability or died had significant suppression periods in their EEG during the first days of life while the patients who had a normal follow-up had no or negligible amount of suppression. Conclusions: This new method for automatic quantification of suppression periods in the raw, neonatal EEG discriminates infants with good from those with poor outcome.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 29
Typ av publikation
konferensbidrag (15)
tidskriftsartikel (14)
Typ av innehåll
refereegranskat (28)
övrigt vetenskapligt/konstnärligt (1)
Författare/redaktör
Lindecrantz, Kaj, 19 ... (11)
Lindecrantz, Kaj (8)
Seoane, Fernando, 19 ... (7)
Kjellmer, Ingemar, 1 ... (7)
Thordstein, Magnus (6)
Seoane, Fernando (5)
visa fler...
Löfgren, Nils, 1969 (5)
Abtahi, Farhad, 1981 ... (2)
Skrifvars, Mikael (2)
Johannsson, Gudmundu ... (2)
Bosaeus, Ingvar, 195 ... (2)
Sandsjö, Leif, 1958 (2)
Ellegård, Lars, 1958 (2)
Gil-Pita, R (2)
Buendia, Ruben, 1982 (2)
Ortiz Catalan, Max J ... (1)
Nilsson, Marie (1)
Nilsson, David (1)
Wiklund, Urban (1)
Karlsson, M (1)
Lu, Ke (1)
Rödby, Kristian (1)
Forsman, Mikael (1)
Diaz-Olivares, Jose ... (1)
Abtahi, Shirin (1)
Berndtsson, Andreas (1)
Müller, Christian, 1 ... (1)
Christie, Michael, 1 ... (1)
Olsson, Torsten, 193 ... (1)
Hummel, Michael (1)
Macías, R. (1)
Gil-Pita, Roberto (1)
Karlsson, Stefan (1)
Degerman, Johan, 197 ... (1)
Kjellmer, I (1)
Persson, Mikael, 195 ... (1)
Bågenholm, Ralph, 19 ... (1)
Thordstein, M. (1)
Sixta, Herbert (1)
Sigrén, Peter (1)
Hamedi, Mahiar (1)
Ayllon, David (1)
Berglin, Lena (1)
Rissanen, Marja (1)
Högberg, Dan, 1965- (1)
Hanson, Lars (1)
Petersson, Joel (1)
Mahdavian, Nafise (1)
Brown, Shannon (1)
Brown, Stephen H. (1)
visa färre...
Lärosäte
Chalmers tekniska högskola (29)
Karolinska Institutet (11)
Göteborgs universitet (9)
RISE (2)
visa fler...
Umeå universitet (1)
Stockholms universitet (1)
Högskolan i Skövde (1)
visa färre...
Språk
Engelska (29)
Forskningsämne (UKÄ/SCB)
Teknik (27)
Medicin och hälsovetenskap (18)
Naturvetenskap (4)
Samhällsvetenskap (3)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy