1.
  • Moores, B M, et al. (författare)
  • RADIUS--closing the circle on the assessment of imaging performance.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 450-7
  • Tidskriftsartikel (refereegranskat)abstract
    • The RADIUS (Radiological Imaging Unification Strategy) project addresses the assessment of image quality in terms of both physical and clinically relevant measures. The aim is to unify our understanding of both types of measure as well as the numerous underlying factors that play a key role in the assessments of imaging performance. In this way it is expected to provide a solid basis for the improvement in radiological safety management, where not only radiation risks are considered but also diagnostic risks of incorrect clinical outcomes (i.e. false positive/false negative). The project has applied a variety of relevant experimental and theoretical methods to this problem, which is generic to medical imaging as a whole. Digital radiography of the chest and the breast has been employed as the clinical imaging domain vehicles for the study. The project addressed the problem from the following directions: role and relevance of pathology, human observer studies including receiver operating characteristics, image quality criteria analysis, structural noise analysis, physical measurements on clinical images, physical measurements on imaging system, modelling of imaging system, modelling of visual processes, modelling of doses delivered and IT-based scientific support strategies. This paper presents an overview of the main outcomes from this project and highlights how the research outcomes actually apply to the real world. In particular, attention will be focused on new and original findings and methods and techniques that have been developed within the framework of the project. The relevance of the project's outcomes to future European research will also be presented.
  •  
2.
  • Tingberg, Anders, et al. (författare)
  • Evaluation of image quality of lumbar spine images: a comparison between FFE and VGA.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 53-61
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: The aim of the present study is to compare two different methods for evaluation of the quality of clinical X-ray images. METHODS: Based on fifteen lumbar spine radiographs, two new sets of images were created. A hybrid image set was created by adding two distributions of artificial lesions to each original image. The image quality parameters spatial resolution and noise were manipulated and a total of 210 hybrid images were created. A set of 105 disease-free images was created by applying the same combinations of spatial resolution and noise to the original images. The hybrid images were evaluated with the free-response forced error experiment (FFE) and the normal images with visual grading analysis (VGA) by nine experienced radiologists. RESULTS: In the VGA study, images with low noise were preferred over images with higher noise levels. The alteration of the MTF had a limited influence on the VGA score. For the FFE study, the visibility of the lesions was independent of the sharpness and the noise level. No correlation was found between the two image quality measures. CONCLUSIONS: FFE is a precise method for evaluation of image quality, but the results are only valid for the type of lesion used in the study, whereas VGA is a more general method for clinical image quality assessment. The results of the FFE study indicate that there might be a potential to lower the dose levels in lumbar spine radiography without losing important diagnostic information.
  •  
3.
  • Tingberg, Anders, et al. (författare)
  • Influence of the characteristic curve on the clinical image quality of lumbar spine and chest radiographs.
  • 2004
  • Ingår i: The British journal of radiology. - : British Institute of Radiology. - 0007-1285 .- 1748-880X. ; 77:915, s. 204-15
  • Tidskriftsartikel (refereegranskat)abstract
    • The "European Guidelines on Quality Criteria for Diagnostic Radiographic Images" do not address the choice of the film characteristic (H&D) curve, which is an important parameter for the description of a radiographic screen-film system. The image contrast of clinical lumbar spine and chest radiographs was altered by digital image processing techniques, simulating images with different H&D curves, both steeper and flatter than the original. The manipulated images were printed on film for evaluation. Seven experienced radiologists evaluated the clinical image quality by analysing the fulfilment of the European Image Criteria (ICS) and by visual grading analysis (VGA) of in total 224 lumbar spine and 360 chest images. A parallel study of the effect of the H&D curve has also been made using a theoretical model. The contrast (DeltaOD) of relevant anatomical details was calculated, using a Monte Carlo simulation-model of the complete imaging system including a 3D voxel phantom of a patient. Correlations between the calculated contrast and the radiologists' assessment by VGA were sought. The results of the radiologists' assessment show that the quality in selected regions of lumbar spine and chest images can be significantly improved by the use of films with a steeper H&D curve compared with the standard latitude film. Significant (p<0.05) correlations were found between the VGA results and the calculations of the contrast of transverse processes and trabecular details in the lumbar spine vertebrae, and with the contrast of blood vessels in the retrocardiac area of the chest.
  •  