SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "LAR1:liu ;pers:(Smedby Örjan)"

Sökning: LAR1:liu > Smedby Örjan

  • Resultat 1-10 av 247
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aalto, Anne, et al. (författare)
  • Brain magnetic resonance imaging does not contribute to the diagnosis of chronic neuroborreliosis
  • 2007
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 48:7, s. 755-762
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Borrelia infections, especially chronic neuroborreliosis ( NB), may cause considerable diagnostic problems. This diagnosis is based on symptoms and findings in the cerebrospinal fluid but is not always conclusive. Purpose: To evaluate brain magnetic resonance imaging ( MRI) in chronic NB, to compare the findings with healthy controls, and to correlate MRI findings with disease duration. Material and Methods: Sixteen well- characterized patients with chronic NB and 16 matched controls were examined in a 1.5T scanner with a standard head coil. T1- ( with and without gadolinium), T2-, and diffusion- weighted imaging plus fluid- attenuated inversion recovery ( FLAIR) imaging were used. Results: White matter lesions and lesions in the basal ganglia were seen in 12 patients and 10 controls ( no significant difference). Subependymal lesions were detected in patients down to the age of 25 and in the controls down to the age of 43. The number of lesions was correlated to age both in patients ( rho=0.83, P < 0.01) and in controls ( rho=0.61, P < 0.05), but not to the duration of disease. Most lesions were detected with FLAIR, but many also with T2- weighted imaging. Conclusion: A number of MRI findings were detected in patients with chronic NB, although the findings were unspecific when compared with matched controls and did not correlate with disease duration. However, subependymal lesions may constitute a potential finding in chronic NB.
  •  
2.
  •  
3.
  • Ahle, Margareta, 1966- (författare)
  • Necrotising Enterocolitis : epidemiology and imaging
  • 2017
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Necrotising enterocolitis (NEC) is a potentially devastating intestinal inflammation of multifactorial aetiology in premature or otherwise vulnerable neonates. Because of the broad spectrum of presentations, diagnosis and timing of surgical intervention may be challenging, and imaging needs to be an integrated part of management.The first four studies included in this thesis used routinely collected, nationwide register data to describe the incidence of NEC in Sweden 1987‒2009, its variation with time, seasonality, space-time clustering, and associations with maternal, gestational, and perinatal factors, and the risk of intestinal failure in the aftermath of the disease.Early infant survival increased dramatically during the study period. The incidence rate of NEC was 0.34 per 1,000 live births, rising from 0.26 per 1,000 live births in the first six years of the study period to 0.57 in the last five. The incidence rates in the lowest birth weights were 100‒160 times those of the entire birth cohort. Seasonal variation was found, as well as space-time clustering in association with delivery hospitals but not with maternal residential municipalities.Comparing NEC cases with matched controls, some factors, positively associated with NEC, were isoimmunisation, fetal distress, caesarean section, persistent ductus arteriosus, cardiac and gastrointestinal malformations, and chromosomal abnormalities. Negative associations included maternal pre-eclampsia, maternal urinary infection, and premature rupture of the membranes. Intestinal failure occurred in 6% of NEC cases and 0.4% of controls, with the highest incidence towards the end of the study period.The last study investigated current practices and perceptions of imaging in the management of NEC, as reported by involved specialists. There was great consensus on most issues. Areas in need of further study seem mainly related to imaging routines, the use of ultrasound, and indications for surgery.Developing alongside the progress of neonatal care, NEC is a complex, multifactorial disease, with shifting patterns of predisposing and precipitating causes, and potentially serious long-term complications. The findings of seasonal variation, spacetime clustering, and negative associations with antenatal exposure to infectious agents, fit into the growing understanding of the central role of bacteria and immunological processes in normal maturation of the intestinal canal as well as in the pathogenesis of NEC. Imaging in the management of NEC may be developed through future studies combining multiple diagnostic parameters in relation to clinical outcome.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  • Andersson, Mats, et al. (författare)
  • Adaptiv filtering of 4D-heart CT for image denoising and patient safety
  • 2010
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • The aim of this medical image science project is to increase patient safety in terms of improved image quality and reduced exposure to ionizing radiation in CT. The means to achieve these goals is to develop and evaluate an efficient adaptive filtering (denoising/image enhancement) method that fully explores true 4D image acquisition modes. Four-dimensional (4D) medical image data are captured as a time sequence of image volumes. During 4D image acquisition, a 3D image of the patient is recorded at regular time intervals. The resulting data will consequently have three spatial dimensions and one temporal dimension. Increasing the dimensionality of the data impose a major increase the computational demands. The initial linear filtering which is the cornerstone in all adaptive image enhancement algorithms increase exponentially with the dimensionality. On the other hand the potential gain in Signal to Noise Ratio (SNR) also increase exponentially with the dimensionality. This means that the same gain in noise reduction that can be attained by performing the adaptive filtering in 3D as opposed to 2D can be expected to occur once more by moving from 3D to 4D. The initial tests on on both synthetic and clinical 4D images has resulted in a significant reduction of the noise level and an increased detail compared to 2D and 3D methods. When tuning the parameters for adaptive filtering is extremely important to attain maximal diagnostic value which not necessarily coincide with an an eye pleasing image for a layman. Although this application focus on CT the resulting adaptive filtering methods will be beneficial for a wide range of 3D/4D medical imaging modalities e.g. shorter acquisition time in MRI and improved elimination of noise in 3D or 4D ultrasound datasets.
  •  
8.
  • Andersson, Malin, et al. (författare)
  • How to measure renal artery stenosis - a retrospective comparison of morphological measurement approaches in relation to hemodynamic significance
  • 2015
  • Ingår i: BMC Medical Imaging. - : BioMed Central. - 1471-2342. ; 15
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Although it is well known that renal artery stenosis may cause renovascular hypertension, it is unclear how the degree of stenosis should best be measured in morphological images. The aim of this study was to determine which morphological measures from Computed Tomography Angiography (CTA) and Magnetic Resonance Angiography (MRA) are best in predicting whether a renal artery stenosis is hemodynamically significant or not. Methods: Forty-seven patients with hypertension and a clinical suspicion of renovascular hypertension were examined with CTA, MRA, captopril-enhanced renography (CER) and captopril test (Ctest). CTA and MRA images of the renal arteries were analyzed by two readers using interactive vessel segmentation software. The measures included minimum diameter, minimum area, diameter reduction and area reduction. In addition, two radiologists visually judged the diameter reduction without automated segmentation. The results were then compared using limits of agreement and intra-class correlation, and correlated with the results from CER combined with Ctest (which were used as standard of reference) using receiver operating characteristics (ROC) analysis. Results: A total of 68 kidneys had all three investigations (CTA, MRA and CER + Ctest), where 11 kidneys (16.2 %) got a positive result on the CER + Ctest. The greatest area under ROC curve (AUROC) was found for the area reduction on MRA, with a value of 0.91 (95 % confidence interval 0.82-0.99), excluding accessory renal arteries. As comparison, the AUROC for the radiologists' visual assessments on CTA and MRA were 0.90 (0.82-0.98) and 0.91 (0.83-0.99) respectively. None of the differences were statistically significant. Conclusions: No significant differences were found between the morphological measures in their ability to predict hemodynamically significant stenosis, but a tendency of MRA having higher AUROC than CTA. There was no significant difference between measurements made by the radiologists and measurements made with fuzzy connectedness segmentation. Further studies are required to definitely identify the optimal measurement approach.
  •  
9.
  • Andersson, Thord, et al. (författare)
  • Consistent intensity inhomogeneity correction in water-fat MRI
  • 2015
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley-Blackwell. - 1053-1807 .- 1522-2586. ; 42:2
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To quantitatively and qualitatively evaluate the water-signal performance of the consistent intensity inhomogeneity correction (CIIC) method to correct for intensity inhomogeneitiesMETHODS: Water-fat volumes were acquired using 1.5 Tesla (T) and 3.0T symmetrically sampled 2-point Dixon three-dimensional MRI. Two datasets: (i) 10 muscle tissue regions of interest (ROIs) from 10 subjects acquired with both 1.5T and 3.0T whole-body MRI. (ii) Seven liver tissue ROIs from 36 patients imaged using 1.5T MRI at six time points after Gd-EOB-DTPA injection. The performance of CIIC was evaluated quantitatively by analyzing its impact on the dispersion and bias of the water image ROI intensities, and qualitatively using side-by-side image comparisons.RESULTS: CIIC significantly ( P1.5T≤2.3×10-4,P3.0T≤1.0×10-6) decreased the nonphysiological intensity variance while preserving the average intensity levels. The side-by-side comparisons showed improved intensity consistency ( Pint⁡≤10-6) while not introducing artifacts ( Part=0.024) nor changed appearances ( Papp≤10-6).CONCLUSION: CIIC improves the spatiotemporal intensity consistency in regions of a homogenous tissue type.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 247
Typ av publikation
tidskriftsartikel (114)
konferensbidrag (101)
doktorsavhandling (15)
proceedings (redaktörskap) (8)
bokkapitel (3)
licentiatavhandling (3)
visa fler...
annan publikation (2)
forskningsöversikt (1)
visa färre...
Typ av innehåll
refereegranskat (169)
övrigt vetenskapligt/konstnärligt (78)
Författare/redaktör
Smedby, Örjan, 1956- (83)
Lundberg, Peter, 195 ... (26)
Dahlström, Nils, 196 ... (22)
Brismar, Torkel (21)
Dahlqvist Leinhard, ... (20)
visa fler...
Smedby, Örjan, Profe ... (19)
Persson, Anders, 195 ... (19)
Moreno, Rodrigo, 197 ... (18)
Borga, Magnus (15)
Lundberg, Peter (15)
Dahlqvist Leinhard, ... (14)
Wang, Chunliang, 198 ... (14)
Smedby, Örjan, Profe ... (13)
Wang, Chunliang (12)
Klintström, Eva (11)
Kihlberg, Johan, 197 ... (11)
Kechagias, Stergios (10)
Romu, Thobias (10)
Persson, Anders (10)
Forsgren, Mikael (10)
Klintström, Benjamin (9)
Sandborg, Michael (9)
Norén, Bengt, 1955- (9)
Landtblom, Anne-Mari ... (8)
Almer, Sven (8)
Dahlström, Nils (8)
Kihlberg, Johan (7)
de Geer, Jakob (7)
Nilsson, S. (6)
Ahlström, H. (6)
Nyström, Fredrik (6)
Moreno, Rodrigo (6)
Erikson, U (6)
Fredrikson, Mats (5)
Larsson, Elna-Marie (5)
Sandborg, Michael, 1 ... (5)
Tisell, Anders (5)
Tisell, Anders, 1981 ... (4)
Klintström, Eva, 195 ... (4)
Frimmel, Hans (4)
Nilsson, Sven (4)
Brismar, T (4)
Norén, Bengt (4)
Nyström, Ingela (4)
Blystad, Ida (4)
Sandström, P. (4)
Weis, J (4)
Rossitti, Sandro (4)
Carleberg, Per (4)
visa färre...
Lärosäte
Linköpings universitet (247)
Kungliga Tekniska Högskolan (47)
Uppsala universitet (20)
Karolinska Institutet (16)
Lunds universitet (2)
Umeå universitet (1)
visa fler...
Chalmers tekniska högskola (1)
visa färre...
Språk
Engelska (243)
Svenska (4)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (72)
Teknik (55)
Naturvetenskap (21)
Samhällsvetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy